SPITZENBERGER & SPIES Analog High Performance Amplifiers
Automated Test Systems
Automotive Supply Simulation Systems
Avionic Supply Simulation System
Basic EMC Test System
Battery Energy Storage Systems (BESS)
Car Supply Simulation PAS GN/Kfz
Current And Voltage Sources
• APS – AC/DC – 4 Quadrant Voltage Amplifier
• ACS – AC/DC 4- Quadrant Current Amplifier
• LVA Series Of 2-/4- Quadrant Voltage Amplifiers
• PAS – AC/DC 4- Quadrant Voltage Amplifiers
• DCS – AC Switching Current Amplifier
• EV – AC Voltage Amplifiers
Mains Supply Simulation System
PHIL – The Benefits Of Using SpS Linear Amplifiers In PHIL
PHIL Power – Hardware – In – The – Loop
Photovoltaic Simulators – Test Results For Inverter Test
Railway Supply Simulation System
Test System For BESS For Testing The Characteristic Of Battery Energy Storage Systems
Test System For Magnetic Field Simulation
Test System For Solar Inverters
The Bench For Circuit Breaker Testing
Spitzenberger & Spies-Test Automated
RELIANT EMC PRODUCT LINES
MANUFACTURERS
Request a Quote / Contact Us!
RELIANT EMC Product List for Spitzenberger & Spies GMBH & CO. KG
Spitzenberger & Spies GmbH & Co. KG Price List | ||
April 8 2013 | ||
Category | Product | Product Descriptions |
4-Quadrant Amplifier, type PAS 1000 | ||
A) Power unit | 4-Quadrant Amplifier type PAS 1000 | Pcont:1000VA/Pshort-time:2000VA/Ppeak:6400VA/ V:0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC )/ f:DC … 5kHz(-3dB)/Incl. 4 line display with voltage and current indication/4pad-keyboard for manual control |
B1) Control unit – DDS 2 | Variable Oscillator, type DDS 2 | DC and sine-wave/f:100mHz … 5kHz/Frequency resolution:100mHz/ Amplitude resolution:<100mV/Operation software |
Basic configuration PAS 1000 with DDS 2: | (DC and sine-wave) | |
B2) Control unit – SyCore (instead of DDS 2) | Control unit type SyCore 2M1 | – Basic unit, incl. display, keyboard and incremental unit; – Synthesizer (single-phase – 1MB RAM); – Synthesizer (single-phase – 1MB RAM) incl. adder AD-11; – Multiplier unit single-phase; – IEEE 488 Interface; – Software SPS SignalManager for Windows |
Basic configuration PAS 1000 with SyCore: | (Free programmable wave shape/External specification of voltage courses is possible) | |
Options for 4-Quadrant Amplifier PAS 1000 | ||
01: | IEEE 488 Interface | Not required in combination with control unit type SyCore |
06: | Output voltage monitor (electrically isolated) | |
07: | Output current monitor (electrically isolated) | |
10: | Internal resistance compensation | |
11-56Z: | Additional voltage range | V:0 … 56Vrms (±79VDC ) |
11-300: | Special voltages | V:0 … 150Vrms (±212VDC )/0 … 300Vrms (±424VDC)/ Replaces standard range V:0 … 135Vrms (±191VDC )/ 0 … 270Vrms (±382VDC ) |
11-300Z: | Special voltage and additional voltage range | V:0 … 60Vrms (±85VDC )/V:0 … 150Vrms (±212VDC )/ 0 … 300Vrms (±424VDC )/Replaces standard range V:0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-630/DC: | Additional DC-voltage range | V:0 … +630VDC /In combination with option 11-300 or 11-300Z |
13-15: | Special frequency range DC … | 15kHz (-3dB) |
13-30: | Special frequency range DC | 30kHz (-3dB) |
17-300: | Floating output | Max. voltage between earth and ground of the output of the amplifier:<300Vrms |
21: | Parallel operation mode (DC … 5kHz/Only with SyCore) | To increase the output power of an amplifier, up to three similar amplifiers may be connected in parallel |
24-P: | Programmable internal impedance | R:100mΩ … 8Ω/Resolution:100mΩ/ L:100µH … 12.8mH/Resolution:100µH |
28-540/C: | Voltage transformer type UT 1000/540/C | Pcont:1000VA/VInput:0 … 270Vrms / VOutput:0 … 400Vrms /0 … 540Vrms /f:45Hz … 5kHz(-3dB)/ With measurement adaptation to PAS 1000 |
Options for oscillator DDS 2 | ||
D03: | DC-control input 0 … 10V control of amplitude and frequency | |
D09: | Adjustable current limit with switch-off | |
Options for control unit SyCore | ||
Analyzer 2 channel (voltage and current) | ||
Additional measurements: | – P, W, VA and power factor; – Frequency; – Crest factor; – Oscilloscope function |
|
SyCore – Upgrade (Event-Trigger) | – Oscilloscope trigger signal at voltage interruptions and/or voltage changes; – 2 x trigger inputs for interactive monitoring (pause and break-off) with reply to the software |
|
D09: Adjustable current limit with switch-off | ||
Desk-top casing | ||
Desk-top casing 4U (for PAS 1000 with DDS 2) | Color light Grey (RAL7035)/H=238mm; W=490mm; D=650mm | |
Desk-top casing 7U (for PAS 1000 with SyCore) | Color light Grey (RAL7035)/H=371mm; W=490mm; D=650mm | |
Desk-top casing 4U (for UT 1000/540/C) | Color light Grey (RAL7035)/H=238mm; W=490mm; D=650mm | |
Option for Personal Computer | ||
GPIB-USB | IEEE 488 Interface type GPIB-USB-HS | Manufacturer: National Instruments |
optionally: | ||
PCI-GPIB: | IEEE 488 Interface type PCI-GPIB | Manufacturer: National Instruments |
optionally: | ||
KPC 488: | IEEE 488 Interface type KPC 488.2 | Manufacturer: Keithley |
Spitzenberger & Spies GmbH & Co. KG Price List | ||
April 8 2013 | ||
Category | Product | Product Descriptions |
4-Quadrant Amplifier, type PAS 2500 | ||
A) Power unit | 4-Quadrant Amplifier type PAS 2500 | Pcont:2500VA/Pshort-time:5000VA/Ppeak:21000VA/ V:0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC )/ f:DC … 5kHz(-3dB)/Incl. 4 line display with voltage and current indication/4pad-keyboard for manual control |
B1) Control unit – DDS | Variable Oscillator, type DDS 2 | DC and sine-wave/f:100mHz … 5kHz/Frequency resolution:100mHz/ Amplitude resolution:<100mV/Operation software |
C) Housing and integration | 19″-Laboratory rack 24U, movable | Color light Grey (RAL7035)/H=1320mm; W=600mm; D=850mm |
Integration and wiring | Incl. connection panel for contacting the EUT | |
Basic configuration PAS 2500 with DDS 2: | (DC and sine-wave) | |
B2) Control unit SyCore (instead of DDS 2) | Control unit type SyCore 2M1 | – Basic unit, incl. display, keyboard and incremental unit; – Synthesizer (single-phase – 1MB RAM); – Synthesizer (single-phase – 1MB RAM) incl. adder AD-11; – Multiplier unit single-phase; – IEEE 488 Interface; – Software SPS SignalManager for Windows |
Basic configuration PAS 2500 with SyCore: | (Free programmable wave shape/External specification of voltage courses is possible) | |
Options for 4-Quadrant Amplifier PAS 2500 | ||
01: | IEEE 488 Interface | Not required in combination with control unit type SyCore |
06: | Output voltage monitor | (electrically isolated) |
07: | Output current monitor | (electrically isolated) |
10: | Internal resistance compensation | |
11-33Z: | Additional voltage range | V:0 … 33Vrms (±47VDC ) |
11-56Z: | Additional voltage range | V:0 … 56Vrms (±79VDC ) |
11-240Z: | Additional voltage range | V:0 … 240Vrms (±339VDC ) |
11-300: | Special voltages | V:0 … 150Vrms (±212VDC )/0 … 300Vrms (±424VDC )/ Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-300Z: | Special voltage and additional voltage range | V:0 … 60Vrms (±85VDC )/0 … 150Vrms (±212VDC )/ 0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-630DC: | Additional DC-voltage range | V:0 … +630VDC /In combination with option 11-300 or 11-300Z |
13-15: | Special frequency range DC | 15kHz (-3dB) |
13-30: | Special frequency range DC | 30kHz (-3dB) |
17-300: | Floating output | Max. voltage between earth and ground of the output of the amplifier:<300Vrms |
21: | Parallel operation mode (DC … 5kHz/Only with SyCore) | To increase the output power of an amplifier, up to three similar amplifiers may be connected in parallel |
24-P: | Programmable internal impedance | R:100mΩ … 8Ω/Resolution:100mΩ/ L:100µH … 12.8mH/Resolution:100µH |
28-540/C: | Voltage transformer type UT 2500/540/C | Pcont:2500VA/VInput:0 … 270Vrms / VOutput:0 … 400Vrms /0 … 540Vrms /f:45Hz … 5kHz(-3dB)/ With measurement adaptation to PAS 2500 |
Options for oscillator DDS 2 | ||
D03: | DC-control input 0 | 10V control of amplitude and frequency |
D09: | Adjustable current limit with switch-off | |
Options for control unit SyCore | ||
Analyzer 2 channel | (voltage and current) | |
Additional measurements: | – P, W, VA and power factor; – Frequency; – Crest factor; – Oscilloscope function |
|
SyCore – Upgrade (Event-Trigger) | – Oscilloscope trigger signal at voltage interruptions and/or voltage changes; – 2 x trigger inputs for interactive monitoring (pause and break-off) with reply to the software |
|
D09: | Adjustable current limit with switch-off | |
Option for personal computer | ||
GPIB-USB | IEEE 488 Interface type GPIB-USB-HS | Manufacturer: National Instruments |
optionally: | ||
PCI-GPIB: | IEEE 488 Interface type PCI-GPIB | Manufacturer: National Instruments |
optionally: | ||
KPC 488: | IEEE 488 Interface type KPC 488.2 | Manufacturer: Keithley |
Spitzenberger & Spies GmbH & Co. KG Price List | ||
April 8 2013 | ||
Category | Product | Product Descriptions |
4-Quadrant Amplifier, type PAS 5000 | ||
A) Power unit | 4-Quadrant Amplifier type PAS 5000 | Pcont:5000VA/Pshort-time:10000VA/Ppeak:42000VA/ V:0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC )/ f:DC … 5kHz(-3dB)/Incl. 4 line display with voltage and current indication/4pad-keyboard for manual control |
B1) Control unit – DDS | Variable Oscillator, type DDS 2 | DC and sine-wave/f:100mHz … 5kHz/Frequency resolution:100mHz/ Amplitude resolution:<100mV/Operation software |
C) Housing and integration | 19″-Laboratory rack 24U, movable | Color light Grey (RAL7035)/H=1320mm; W=600mm; D=850mm |
Integration and wiring | Incl. connection panel for contacting the EUT | |
Basic configuration PAS 5000 with DDS 2: | (DC and sine-wave) | |
B2) Control unit SyCore (instead of DDS 2) | Control unit type SyCore 2M1 | – Basic unit, incl. display, keyboard and incremental unit; – Synthesizer (single-phase – 1MB RAM); – Synthesizer (single-phase – 1MB RAM) incl. adder AD-11; – Multiplier unit single-phase; – IEEE 488 Interface; – Software SPS SignalManager for Windows |
Basic configuration PAS 5000 with SyCore: | (Free programmable wave shape/External specification of voltage courses is possible) | |
Options for 4-Quadrant Amplifier PAS 5000 | ||
01: | IEEE 488 Interface | Not required in combination with control unit type SyCore |
06: | Output voltage monitor | (electrically isolated) |
07: | Output current monitor | (electrically isolated) |
10: | Internal resistance compensation | |
11-33Z: | Additional voltage range | V:0 … 33Vrms (±47VDC ) |
11-56Z: | Additional voltage range | V:0 … 56Vrms (±79VDC ) |
11-240Z: | Additional voltage range | V:0 … 240Vrms (±339VDC ) |
11-300: | Special voltages | V:0 … 150Vrms (±212VDC )/0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-300Z: | Special voltage and additional voltage range | V:0 … 60Vrms (±85VDC )/0 … 150Vrms (±212VDC )/ 0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-630DC: | Additional DC-voltage range | V:0 … +630VDC /In combination with option 11-300 or 11-300Z |
13-15: | Special frequency range DC | 15kHz (-3dB) |
13-30: | Special frequency range DC | 30kHz (-3dB) |
17-300: | Floating output | Max. voltage between earth and ground of the output of the amplifier:<300Vrms |
21: | Parallel operation mode (DC … 5kHz/Only with SyCore) | To increase the output power of an amplifier, up to three similar amplifiers may be connected in parallel |
24-P: | Programmable internal impedance | R:50mΩ … 4Ω/Resolution:50mΩ/ L:50µH … 6.4mH/Resolution:50µH |
28-540/C: | Voltage transformer type UT 5000/540/C | Pcont:5000VA/VInput:0 … 270Vrms / VOutput:0 … 400Vrms /0 … 540Vrms /f:45Hz … 5kHz(-3dB)/ With measurement adaptation to PAS 5000 |
Options for oscillator DDS 2 | ||
D03: | DC-control input 0 | 10V control of amplitude and frequency |
D09: | Adjustable current limit with switch-off | |
Options for control unit SyCore | ||
Analyzer 2 channel (voltage and current) | ||
Additional measurements: | – P, W, VA and power factor; – Frequency; – Crest factor; – Oscilloscope function |
|
SyCore – Upgrade (Event-Trigger) | – Oscilloscope trigger signal at voltage interruptions and/or voltage changes; – 2 x trigger inputs for interactive monitoring (pause and break-off) with reply to the software |
|
D09: | Adjustable current limit with switch-off | |
Option for personal computer | ||
GPIB-USB | IEEE 488 Interface type GPIB-USB-HS | Manufacturer: National Instruments |
optionally: | ||
PCI-GPIB: | IEEE 488 Interface type PCI-GPIB | Manufacturer: National Instruments |
optionally: | ||
KPC 488: | IEEE 488 Interface type KPC 488.2 | Manufacturer: Keithley |
Spitzenberger & Spies GmbH & Co. KG Price List | ||
April 8 2013 | ||
Category | Product | Product Descriptions |
4-Quadrant Amplifier, type PAS 7500 | ||
A) Power unit | 4-Quadrant Amplifier type PAS 7500 | Pcont:7500VA/Pshort-time:15000VA/Ppeak:63000VA/ V:0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC )/ f:DC … 5kHz(-3dB)/Incl. 4 line display with voltage and current indication/4pad-keyboard for manual control |
B1) Control unit – DDS | Variable Oscillator, type DDS 2 | DC and sine-wave/f:100mHz … 5kHz/Frequency resolution:100mHz/ Amplitude resolution:<100mV/Operation software |
C) Housing and integration | 19″-Laboratory rack 37U, movable | Color light Grey (RAL7035)/H=1920mm; W=600mm; D=850mm |
Integration and wiring | Incl. connection panel for contacting the EUT | |
Basic configuration PAS 7500 with DDS 2: | (DC and sine-wave) | |
B2) Control unit SyCore (instead of DDS 2) | Control unit type SyCore 2M1 | – Basic unit, incl. display, keyboard and incremental unit; – Synthesizer (single-phase – 1MB RAM); – Synthesizer (single-phase – 1MB RAM) incl. adder AD-11; – Multiplier unit single-phase; – IEEE 488 Interface; – Software SPS SignalManager for Windows |
Basic configuration PAS 7500 with SyCore: | (Free programmable wave shape/External specification of voltage courses is possible) | |
Options for 4-Quadrant Amplifier PAS 7500 | ||
01: | IEEE 488 Interface | Not required in combination with control unit type SyCore |
06: | Output voltage monitor | (electrically isolated) |
07: | Output current monitor | (electrically isolated) |
10: | Internal resistance compensation | |
11-33Z: | Additional voltage range | V:0 … 33Vrms (±47VDC ) |
11-56Z: | Additional voltage range | V:0 … 56Vrms (±79VDC ) |
11-240Z: | Additional voltage range | V:0 … 240Vrms (±339VDC ) |
11-300: | Special voltages | V:0 … 150Vrms (±212VDC )/0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-300Z: | Special voltage and additional voltage range | V:0 … 60Vrms (±85VDC )/0 … 150Vrms (±212VDC )/ 0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-630DC: | Additional DC-voltage range | V:0 … +630VDC /In combination with option 11-300 or 11-300Z |
13-15: | Special frequency range DC | 15kHz (-3dB) |
13-30: | Special frequency range DC | 30kHz (-3dB) |
17-300: | Floating output | Max. voltage between earth and ground of the output of the amplifier:<300Vrms |
21: | Parallel operation mode (DC … 5kHz/Only with SyCore) | To increase the output power of an amplifier, up to three similar amplifiers may be connected in parallel |
24-P: | Programmable internal impedance | R:50mΩ … 4Ω/Resolution:50mΩ/ L:50µH … 6.4mH/Resolution:50µH |
28-540/C: | Voltage transformer type UT 5000/540/C | Pcont:5000VA/VInput:0 … 270Vrms / VOutput:0 … 400Vrms /0 … 540Vrms /f:45Hz … 5kHz(-3dB)/ With measurement adaptation to PAS 5000 |
Options for oscillator DDS 2 | ||
D03: | DC-control input 0 | 10V control of amplitude and frequency |
D09: | Adjustable current limit with switch-off | |
Options for control unit SyCore | ||
Analyzer 2 channel (voltage and current) | ||
Additional measurements: | – P, W, VA and power factor; – Frequency; – Crest factor; – Oscilloscope function |
|
SyCore – Upgrade (Event-Trigger) | – Oscilloscope trigger signal at voltage interruptions and/or voltage changes; – 2 x trigger inputs for interactive monitoring (pause and break-off) with reply to the software |
|
D09: | Adjustable current limit with switch-off | |
Option for personal computer | ||
GPIB-USB | IEEE 488 Interface type GPIB-USB-HS | Manufacturer: National Instruments |
optionally: | ||
PCI-GPIB: | IEEE 488 Interface type PCI-GPIB | Manufacturer: National Instruments |
optionally: | ||
KPC 488: | IEEE 488 Interface type KPC 488.2 | Manufacturer: Keithley |
Spitzenberger & Spies GmbH & Co. KG Price List | ||
April 8 2013 | ||
Category | Product | Product Descriptions |
4-Quadrant Amplifier, type PAS 10000 | ||
A) Power unit | 4-Quadrant Amplifier type PAS 10000 | Pcont:10000VA/Pshort-time:20000VA/Ppeak:87500VA/ V:0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC )/ f:DC … 5kHz(-3dB)/Incl. 4 line display with voltage and current indication/4pad-keyboard for manual control |
B1) Control unit – DDS | Variable Oscillator, type DDS 2 | DC and sine-wave/f:100mHz … 5kHz/Frequency resolution:100mHz/ Amplitude resolution:<100mV/Operation software |
C) Housing and integration | 19″-Laboratory rack 37U, movable | Color light Grey (RAL7035)/H=1920mm; W=600mm; D=850mm |
Integration and wiring | Incl. connection panel for contacting the EUT | |
Basic configuration PAS 10000 with DDS 2: | (DC and sine-wave) | |
B2) Control unit SyCore (instead of DDS 2) | Control unit type SyCore 2M1 | ,- Basic unit, incl. display, keyboard and incremental unit; – Synthesizer (single-phase – 1MB RAM); – Synthesizer (single-phase – 1MB RAM) incl. adder AD-11; – Multiplier unit single-phase; – IEEE 488 Interface; – Software SPS SignalManager for Windows |
Basic configuration PAS 10000 with SyCore: | (Free programmable wave shape/External specification of voltage courses is possible) | |
Options for 4-Quadrant Amplifier PAS 10000 | ||
01: | IEEE 488 Interface | Not required in combination with control unit type SyCore |
06: | Output voltage monitor | (electrically isolated) |
07: | Output current monitor | (electrically isolated) |
10: | Internal resistance compensation | |
11-33Z: | Additional voltage range | V:0 … 33Vrms (±47VDC ) |
11-56Z: | Additional voltage range | V:0 … 56Vrms (±79VDC ) |
11-240Z: | Additional voltage range | V:0 … 240Vrms (±339VDC ) |
11-300: | Special voltages | V:0 … 150Vrms (±212VDC )/0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-300Z: | Special voltage and additional voltage range | V:0 … 60Vrms (±85VDC )/0 … 150Vrms (±212VDC )/ 0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-630DC: | Additional DC-voltage range | V:0 … +630VDC /In combination with option 11-300 or 11-300Z |
13-15: | Special frequency range DC | 15kHz (-3dB) |
13-30: | Special frequency range DC | 30kHz (-3dB) |
17-300: | Floating output | Max. voltage between earth and ground of the output of the amplifier:<300Vrms |
21: | Parallel operation mode (DC … 5kHz/Only with SyCore) | To increase the output power of an amplifier, up to three similar amplifiers may be connected in parallel |
24-P: | Programmable internal impedance | R:50mΩ … 4Ω/Resolution:50mΩ/ L:50µH … 6.4mH/Resolution:50µH |
28-540/C: | Voltage transformer type UT 5000/540/C | Pcont:5000VA/VInput:0 … 270Vrms / VOutput:0 … 400Vrms /0 … 540Vrms /f:45Hz … 5kHz(-3dB)/ With measurement adaptation to PAS 5000 |
Options for oscillator DDS 2 | ||
D03: | DC-control input 0 | 10V control of amplitude and frequency |
D09: | Adjustable current limit with switch-off | |
Options for control unit SyCore | ||
Analyzer 2 channel (voltage and current) | ||
Additional measurements: | – P, W, VA and power factor; – Frequency; – Crest factor; – Oscilloscope function |
|
SyCore – Upgrade (Event-Trigger) | – Oscilloscope trigger signal at voltage interruptions and/or voltage changes; – 2 x trigger inputs for interactive monitoring (pause and break-off) with reply to the software |
|
D09: | Adjustable current limit with switch-off | |
Option for personal computer | ||
GPIB-USB | IEEE 488 Interface type GPIB-USB-HS | Manufacturer: National Instruments |
optionally: | ||
PCI-GPIB: | IEEE 488 Interface type PCI-GPIB | Manufacturer: National Instruments |
optionally: | ||
KPC 488: | IEEE 488 Interface type KPC 488.2 | Manufacturer: Keithley |
Spitzenberger & Spies GmbH & Co. KG Price List | ||
April 8 2013 | ||
Category | Product | Product Descriptions |
4-Quadrant Amplifier, type PAS 15000 | ||
A) Power unit | 4-Quadrant Amplifier type PAS 15000 | Pcont:15000VA/Pshort-time:30000VA/Ppeak:140000VA/ V:0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC )/ f:DC … 5kHz(-3dB)/Incl. 4 line display with voltage and current indication/4pad-keyboard for manual control |
B1) Control unit – DDS | Variable Oscillator, type DDS 2 | DC and sine-wave/f:100mHz … 5kHz/Frequency resolution:100mHz/ Amplitude resolution:<100mV/Operation software |
C) Housing and integration | 19″-Laboratory rack 42U, with forklift movable | Color light Grey (RAL7035)/H=2120mm; W=600mm; D=1050mm |
Integration and wiring | Incl. connection panel for contacting the EUT | |
Basic configuration PAS 15000 with DDS 2: | (DC and sine-wave) | |
B2) Control unit SyCore (instead of DDS 2) | Control unit type SyCore 2M1 | – Basic unit, incl. display, keyboard and incremental unit; – Synthesizer (single-phase – 1MB RAM); – Synthesizer (single-phase – 1MB RAM) incl. adder AD-11; – Multiplier unit single-phase; – IEEE 488 Interface; – Software SPS SignalManager for Windows |
Basic configuration PAS 15000 with SyCore: | (Free programmable wave shape/External specification of voltage courses is possible) | |
Options for 4-Quadrant Amplifier PAS 15000 | ||
01: | IEEE 488 Interface | Not required in combination with control unit type SyCore |
06: | Output voltage monitor | (electrically isolated) |
07: | Output current monitor | (electrically isolated) |
10: | Internal resistance compensation | |
11-33Z: | Additional voltage range | V:0 … 33Vrms (±47VDC ) |
11-56Z: | Additional voltage range | V:0 … 56Vrms (±79VDC ) |
11-240Z: | Additional voltage range | V:0 … 240Vrms (±339VDC ) |
11-300: | Special voltages | V:0 … 150Vrms (±212VDC )/0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-300Z: | Special voltage and additional voltage range | V:0 … 60Vrms (±85VDC )/0 … 150Vrms (±212VDC )/ 0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-630DC: | Additional DC-voltage range | V:0 … +630VDC /In combination with option 11-300 or 11-300Z |
13-15: | Special frequency range DC | 15kHz (-3dB) |
13-30: | Special frequency range DC | 30kHz (-3dB) |
17-300: | Floating output | Max. voltage between earth and ground of the output of the amplifier:<300Vrms |
21: | Parallel operation mode (DC … 5kHz/Only with SyCore) | To increase the output power of an amplifier, up to three similar amplifiers may be connected in parallel |
24-P: | Programmable internal impedance | R:50mΩ … 4Ω/Resolution:50mΩ/ L:50µH … 6.4mH/Resolution:50µH |
28-540/C: | Voltage transformer type UT 5000/540/C | Pcont:5000VA/VInput:0 … 270Vrms / VOutput:0 … 400Vrms /0 … 540Vrms /f:45Hz … 5kHz(-3dB)/ With measurement adaptation to PAS 5000 |
Options for oscillator DDS 2 | ||
D03: | DC-control input 0 | 10V control of amplitude and frequency |
D09: | Adjustable current limit with switch-off | |
Options for control unit SyCore | ||
Analyzer 2 channel (voltage and current) | ||
Additional measurements: | – P, W, VA and power factor; – Frequency; – Crest factor; – Oscilloscope function |
|
SyCore – Upgrade (Event-Trigger) | – Oscilloscope trigger signal at voltage interruptions and/or voltage changes; – 2 x trigger inputs for interactive monitoring (pause and break-off) with reply to the software |
|
D09: | Adjustable current limit with switch-off | |
Option for personal computer | ||
GPIB-USB | IEEE 488 Interface type GPIB-USB-HS | Manufacturer: National Instruments |
optionally: | ||
PCI-GPIB: | IEEE 488 Interface type PCI-GPIB | Manufacturer: National Instruments |
optionally: | ||
KPC 488: | IEEE 488 Interface type KPC 488.2 | Manufacturer: Keithley |
Spitzenberger & Spies GmbH & Co. KG Price List | ||
April 8 2013 | ||
Category | Product | Product Descriptions |
4-Quadrant Amplifier, type PAS 20000 | ||
A) Power unit | 4-Quadrant Amplifier type PAS 20000 | Pcont:20000VA/Pshort-time:40000VA/Ppeak:200000VA/ V:0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC )/ f:DC … 5kHz(-3dB)/Incl. 4 line display with voltage and current indication/4pad-keyboard for manual control |
B1) Control unit – DDS | Variable Oscillator, type DDS 2 | DC and sine-wave/f:100mHz … 5kHz/Frequency resolution:100mHz/ Amplitude resolution:<100mV/Operation software |
C) Housing and integration | 19″-Laboratory rack 42U, with forklift movable | Color light Grey (RAL7035)/H=2120mm; W=600mm; D=1050mm |
Integration and wiring | ||
Basic configuration PAS 20000 with DDS 2: | (DC and sine-wave) | |
B2) Control unit SyCore (instead of DDS 2) | Control unit type SyCore 2M1 | – Basic unit, incl. display, keyboard and incremental unit; – Synthesizer (single-phase – 1MB RAM); – Synthesizer (single-phase – 1MB RAM) incl. adder AD-11; – Multiplier unit single-phase; – IEEE 488 Interface; – Software SPS SignalManager for Windows |
Basic configuration PAS 20000 with SyCore: | (Free programmable wave shape/External specification of voltage courses is possible) | |
Options for 4-Quadrant Amplifier PAS 20000 | ||
01: | IEEE 488 Interface | Not required in combination with control unit type SyCore |
06: | Output voltage monitor | (electrically isolated) |
07: | Output current monitor | (electrically isolated) |
10: | Internal resistance compensation | |
11-33Z: | Additional voltage range | V:0 … 33Vrms (±47VDC ) |
11-56Z: | Additional voltage range | V:0 … 56Vrms (±79VDC ) |
11-240Z: | Additional voltage range | V:0 … 240Vrms (±339VDC ) |
11-300: | Special voltages | V:0 … 150Vrms (±212VDC )/0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-300Z: | Special voltage and additional voltage range | V:0 … 60Vrms (±85VDC )/0 … 150Vrms (±212VDC )/ 0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-630DC: | Additional DC-voltage range | V:0 … +630VDC /In combination with option 11-300 or 11-300Z |
13-15: | Special frequency range DC | 15kHz (-3dB) |
17-300: | Floating output | Max. voltage between earth and ground of the output of the amplifier:<300Vrms |
21: | Parallel operation mode (DC … 5kHz/Only with SyCore) | To increase the output power of an amplifier, up to three similar amplifiers may be connected in parallel |
24-P: | Programmable internal impedance | R:10mΩ … 1Ω/Resolution:10mΩ/ L:10µH … 1.6mH/Resolution:10µH |
28-540/C: | Voltage transformer type UT 20000/540/C | Pcont:20000VA/VInput:0 … 270Vrms / VOutput:0 … 400Vrms /0 … 540Vrms /f:45Hz … 5kHz(-3dB)/ With measurement adaptation to PAS 20000 |
Options for oscillator DDS 2 | ||
D03: | DC-control input 0 | 10V control of amplitude and frequency |
D09: | Adjustable current limit with switch-off | |
Options for control unit SyCore | ||
Analyzer 2 channel (voltage and current) | ||
Additional measurements: | – P, W, VA and power factor; – Frequency; – Crest factor; – Oscilloscope function |
|
SyCore – Upgrade (Event-Trigger) | – Oscilloscope trigger signal at voltage interruptions and/or voltage changes; – 2 x trigger inputs for interactive monitoring (pause and break-off) with reply to the software |
|
D09: | Adjustable current limit with switch-off | |
Option for personal computer | ||
GPIB-USB | IEEE 488 Interface type GPIB-USB-HS | Manufacturer: National Instruments |
optionally: | ||
PCI-GPIB: | IEEE 488 Interface type PCI-GPIB | Manufacturer: National Instruments |
optionally: | ||
KPC 488: | IEEE 488 Interface type KPC 488.2 | Manufacturer: Keithley |
Spitzenberger & Spies GmbH & Co. KG Price List | ||
April 8 2013 | ||
4-Quadrant Amplifier, type PAS 25000 | ||
A) Power unit | 4-Quadrant Amplifier type PAS 25000 | Pcont:25000VA/Pshort-time:50000VA/Ppeak:210000VA/ V:0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC )/ f:DC … 5kHz(-3dB)/Incl. 4 line display with voltage and current indication/4pad-keyboard for manual control |
B1) Control unit – DDS | Variable Oscillator, type DDS 2 | DC and sine-wave/f:100mHz … 5kHz/Frequency resolution:100mHz/ Amplitude resolution:<100mV/Operation software |
C) Housing and integration | 19″-Laboratory rack 42U, with forklift movable | Color light Grey (RAL7035)/H=2120mm; W=600mm; D=1050mm |
Integration and wiring | ||
Basic configuration PAS 25000 with DDS 2: | (DC and sine-wave) | |
B2) Control unit SyCore (instead of DDS 2) | Control unit type SyCore 2M1 | – Basic unit, incl. display, keyboard and incremental unit; – Synthesizer (single-phase – 1MB RAM); – Synthesizer (single-phase – 1MB RAM) incl. adder AD-11; – Multiplier unit single-phase; – IEEE 488 Interface; – Software SPS SignalManager for Windows |
Basic configuration PAS 25000 with SyCore: | (Free programmable wave shape/External specification of voltage courses is possible) | |
Options for 4-Quadrant Amplifier PAS 25000 | ||
01: | IEEE 488 Interface | Not required in combination with control unit type SyCore |
06: | Output voltage monitor | (electrically isolated) |
07: | Output current monitor | (electrically isolated) |
10: | Internal resistance compensation | |
11-33Z: | Additional voltage range | V:0 … 33Vrms (±47VDC ) |
11-56Z: | Additional voltage range | V:0 … 56Vrms (±79VDC ) |
11-240Z: | Additional voltage range | V:0 … 240Vrms (±339VDC ) |
11-300: | Special voltages | V:0 … 150Vrms (±212VDC )/0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-300Z: | Special voltage and additional voltage range | V:0 … 60Vrms (±85VDC )/0 … 150Vrms (±212VDC )/ 0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-630DC: | Additional DC-voltage range | V:0 … +630VDC /In combination with option 11-300 or 11-300Z |
13-15: | Special frequency range DC | 15kHz (-3dB) |
17-300: | Floating output | Max. voltage between earth and ground of the output of the amplifier:<300Vrms |
21: | Parallel operation mode (DC … 5kHz/Only with SyCore) | To increase the output power of an amplifier, up to three similar amplifiers may be connected in parallel |
24-P: | Programmable internal impedance | R:10mΩ … 1Ω/Resolution:10mΩ/ L:10µH … 1.6mH/Resolution:10µH |
28-540/C: | Voltage transformer type UT 20000/540/C | Pcont:20000VA/VInput:0 … 270Vrms / VOutput:0 … 400Vrms /0 … 540Vrms /f:45Hz … 5kHz(-3dB)/ With measurement adaptation to PAS 20000 |
Options for oscillator DDS 2 | ||
D03: | DC-control input 0 | 10V control of amplitude and frequency |
D09: | Adjustable current limit with switch-off | |
Options for control unit SyCore | ||
Analyzer 2 channel (voltage and current) | ||
Additional measurements: | – P, W, VA and power factor; – Frequency; – Crest factor; – Oscilloscope function |
|
SyCore – Upgrade (Event-Trigger) | – Oscilloscope trigger signal at voltage interruptions and/or voltage changes; – 2 x trigger inputs for interactive monitoring (pause and break-off) with reply to the software |
|
D09: | Adjustable current limit with switch-off | |
Option for personal computer | ||
GPIB-USB | IEEE 488 Interface type GPIB-USB-HS | Manufacturer: National Instruments |
optionally: | ||
PCI-GPIB: | IEEE 488 Interface type PCI-GPIB | Manufacturer: National Instruments |
optionally: | ||
KPC 488: | IEEE 488 Interface type KPC 488.2 | Manufacturer: Keithley |
Spitzenberger & Spies GmbH & Co. KG Price List | ||
April 8 2013 | ||
Category | Product | Product Descriptions |
4-Quadrant Amplifier, type PAS 30000 | ||
A) Power unit | 4-Quadrant Amplifier type PAS 30000 | Pcont:30000VA/Pshort-time:60000VA/Ppeak:252000VA/ V:0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC )/ f:DC … 5kHz(-3dB)/Incl. 4 line display with voltage and current indication/4pad-keyboard for manual control |
B1) Control unit – DDS | Variable Oscillator, type DDS 2 | DC and sine-wave/f:100mHz … 5kHz/Frequency resolution:100mHz/ Amplitude resolution:<100mV/Operation software |
C) Housing and integration | 19″-Laboratory rack 46U, with forklift movable | Color light Grey (RAL7035)/H=2320mm; W=600mm; D=1050mm |
Integration and wiring | ||
Basic configuration PAS 30000 with DDS 2: | (DC and sine-wave) | |
B2) Control unit SyCore (instead of DDS 2) | Control unit type SyCore 2M1 | – Basic unit, incl. display, keyboard and incremental unit; – Synthesizer (single-phase – 1MB RAM); – Synthesizer (single-phase – 1MB RAM) incl. adder AD-11; – Multiplier unit single-phase; – IEEE 488 Interface; – Software SPS SignalManager for Windows |
Basic configuration PAS 30000 with SyCore: | (Free programmable wave shape/External specification of voltage courses is possible) | |
Options for 4-Quadrant Amplifier PAS 25000 | ||
01: | IEEE 488 Interface | Not required in combination with control unit type SyCore |
06: | Output voltage monitor | (electrically isolated) |
07: | Output current monitor | (electrically isolated) |
10: | Internal resistance compensation | |
11-33Z: | Additional voltage range | V:0 … 33Vrms (±47VDC ) |
11-56Z: | Additional voltage range | V:0 … 56Vrms (±79VDC ) |
11-240Z: | Additional voltage range | V:0 … 240Vrms (±339VDC ) |
11-300: | Special voltages | V:0 … 150Vrms (±212VDC )/0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-300Z: | Special voltage and additional voltage range | V:0 … 60Vrms (±85VDC )/0 … 150Vrms (±212VDC )/ 0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-630DC: | Additional DC-voltage range | V:0 … +630VDC /In combination with option 11-300 or 11-300Z |
13-15: | Special frequency range DC | 15kHz (-3dB) |
17-300: | Floating output | Max. voltage between earth and ground of the output of the amplifier:<300Vrms |
21: | Parallel operation mode (DC … 5kHz/Only with SyCore) | To increase the output power of an amplifier, up to three similar amplifiers may be connected in parallel |
24-P: | Programmable internal impedance | R:10mΩ … 1Ω/Resolution:10mΩ/ L:10µH … 1.6mH/Resolution:10µH |
28-540/C: | Voltage transformer type UT 20000/540/C | Pcont:20000VA/VInput:0 … 270Vrms / VOutput:0 … 400Vrms /0 … 540Vrms /f:45Hz … 5kHz(-3dB)/ With measurement adaptation to PAS 20000 |
Options for oscillator DDS 2 | ||
D03: | DC-control input 0 | 10V control of amplitude and frequency |
D09: | Adjustable current limit with switch-off | |
Options for control unit SyCore | ||
Analyzer 2 channel (voltage and current) | ||
Additional measurements: | – P, W, VA and power factor; – Frequency; – Crest factor; – Oscilloscope function |
|
SyCore – Upgrade (Event-Trigger) | – Oscilloscope trigger signal at voltage interruptions and/or voltage changes; – 2 x trigger inputs for interactive monitoring (pause and break-off) with reply to the software |
|
D09: | Adjustable current limit with switch-off | |
Option for personal computer | ||
GPIB-USB | IEEE 488 Interface type GPIB-USB-HS | Manufacturer: National Instruments |
optionally: | ||
PCI-GPIB: | IEEE 488 Interface type PCI-GPIB | Manufacturer: National Instruments |
optionally: | ||
KPC 488: | IEEE 488 Interface type KPC 488.2 | Manufacturer: Keithley |
Spitzenberger & Spies GmbH & Co. KG Price List | ||
April 8 2013 | ||
Category | Product | Product Descriptions |
4-Quadrant Amplifier, type PAS 40000 | ||
A) Power unit | 4-Quadrant Amplifier type PAS 40000 | Pcont:40000VA/Pshort-time:80000VA/Ppeak:400000VA/ V:0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC )/ f:DC … 5kHz(-3dB)/Incl. 4 line display with voltage and current indication/4pad-keyboard for manual control |
B1) Control unit – DDS | Variable Oscillator, type DDS 2 | DC and sine-wave/f:100mHz … 5kHz/Frequency resolution:100mHz/ Amplitude resolution:<100mV/Operation software |
C) Housing and integration | 19″-Laboratory rack 42U, with forklift movable | Color light Grey (RAL7035)/H=2120mm; W=1200mm; D=1050mm |
19″-Laboratory rack 42U, with forklift movable | Color light Grey (RAL7035)/H=2120mm; W=800mm; D=1050mm | |
Integration and wiring | ||
Basic configuration PAS 40000 with DDS 2: | (DC and sine-wave) | |
B2) Control unit SyCore (instead of DDS 2) | Control unit type SyCore 2M1 | – Basic unit, incl. display, keyboard and incremental unit; – Synthesizer (single-phase – 1MB RAM); – Synthesizer (single-phase – 1MB RAM) incl. adder AD-11; – Multiplier unit single-phase; – IEEE 488 Interface; – Software SPS SignalManager for Windows |
Basic configuration PAS 40000 with SyCore: | (Free programmable wave shape/External specification of voltage courses is possible) | |
Options for 4-Quadrant Amplifier PAS 40000 | ||
01: | IEEE 488 Interface | Not required in combination with control unit type SyCore |
06: | Output voltage monitor | (electrically isolated) |
07: | Output current monitor | (electrically isolated) |
10: | Internal resistance compensation | |
11-33Z: | Additional voltage range | V:0 … 33Vrms (±47VDC ) |
11-56Z: | Additional voltage range | V:0 … 56Vrms (±79VDC ) |
11-240Z: | Additional voltage range | V:0 … 240Vrms (±339VDC ) |
11-300: | Special voltages | V:0 … 150Vrms (±212VDC )/0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-300Z: | Special voltage and additional voltage range | V:0 … 60Vrms (±85VDC )/0 … 150Vrms (±212VDC )/ 0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-630DC: | Additional DC-voltage range | V:0 … +630VDC /In combination with option 11-300 or 11-300Z |
17-300: | Floating output | Max. voltage between earth and ground of the output of the amplifier:<300Vrms |
24-P: | Programmable internal impedance | R:10mΩ … 1Ω/Resolution:10mΩ/ L:10µH … 1.6mH/Resolution:10µH |
28-540/C: | Voltage transformer type UT 20000/540/C | Pcont:20000VA/VInput:0 … 270Vrms / VOutput:0 … 400Vrms /0 … 540Vrms /f:45Hz … 5kHz(-3dB)/ With measurement adaptation to PAS 20000 |
Options for oscillator DDS 2 | ||
D03: | DC-control input 0 | 10V control of amplitude and frequency |
D09: | Adjustable current limit with switch-off | |
Options for control unit SyCore | ||
Analyzer 2 channel (voltage and current) | ||
Additional measurements: | – P, W, VA and power factor; – Frequency; – Crest factor; – Oscilloscope function |
|
SyCore – Upgrade (Event-Trigger) | – Oscilloscope trigger signal at voltage interruptions and/or voltage changes; – 2 x trigger inputs for interactive monitoring (pause and break-off) with reply to the software |
|
D09: | Adjustable current limit with switch-off | |
Option for personal computer | ||
GPIB-USB | IEEE 488 Interface type GPIB-USB-HS | Manufacturer: National Instruments |
optionally: | ||
PCI-GPIB: | IEEE 488 Interface type PCI-GPIB | Manufacturer: National Instruments |
optionally: | ||
KPC 488: | IEEE 488 Interface type KPC 488.2 | Manufacturer: Keithley |
Spitzenberger & Spies GmbH & Co. KG Price List | ||
April 8 2013 | ||
Category | Product | Product Descriptions |
4-Quadrant Amplifier, type PAS 50000 | ||
A) Power unit | 4-Quadrant Amplifier type PAS 50000 | Pcont:50000VA/Pshort-time:100000VA/Ppeak:420000VA/ V:0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC )/ f:DC … 5kHz(-3dB)/Incl. 4 line display with voltage and current indication/4pad-keyboard for manual control |
B1) Control unit – DDS | Variable Oscillator, type DDS 2 | DC and sine-wave/f:100mHz … 5kHz/Frequency resolution:100mHz/ Amplitude resolution:<100mV/Operation software |
C) Housing and integration | 19″-Laboratory rack 42U, with forklift movable | Color light Grey (RAL7035)/H=2120mm; W=1200mm; D=1050mm |
19″-Laboratory rack 42U, with forklift movable | Color light Grey (RAL7035)/H=2120mm; W=800mm; D=1050mm | |
Integration and wiring | ||
Basic configuration PAS 50000 with DDS 2: | (DC and sine-wave) | |
B2) Control unit SyCore (instead of DDS 2) | Control unit type SyCore 2M1 | – Basic unit, incl. display, keyboard and incremental unit; – Synthesizer (single-phase – 1MB RAM); – Synthesizer (single-phase – 1MB RAM) incl. adder AD-11; – Multiplier unit single-phase; – IEEE 488 Interface; – Software SPS SignalManager for Windows |
Basic configuration PAS 50000 with SyCore: | (Free programmable wave shape/External specification of voltage courses is possible) | |
Options for 4-Quadrant Amplifier PAS 50000 | ||
01: | IEEE 488 Interface | Not required in combination with control unit type SyCore |
06: | Output voltage monitor | (electrically isolated) |
07: | Output current monitor | (electrically isolated) |
10: | Internal resistance compensation | |
11-33Z: | Additional voltage range | V:0 … 33Vrms (±47VDC ) |
11-56Z: | Additional voltage range | V:0 … 56Vrms (±79VDC ) |
11-240Z: | Additional voltage range | V:0 … 240Vrms (±339VDC ) |
11-300: | Special voltages | V:0 … 150Vrms (±212VDC )/0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-300Z: | Special voltage and additional voltage range | V:0 … 60Vrms (±85VDC )/0 … 150Vrms (±212VDC )/ 0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-630DC: | Additional DC-voltage range | V:0 … +630VDC /In combination with option 11-300 or 11-300Z |
17-300: | Floating output | Max. voltage between earth and ground of the output of the amplifier:<300Vrms |
24-P: | Programmable internal impedance | R:10mΩ … 1Ω/Resolution:10mΩ/ L:10µH … 1.6mH/Resolution:10µH |
28-540/C: | Voltage transformer type UT 20000/540/C | Pcont:20000VA/VInput:0 … 270Vrms / VOutput:0 … 400Vrms /0 … 540Vrms /f:45Hz … 5kHz(-3dB)/ With measurement adaptation to PAS 20000 |
Options for oscillator DDS 2 | ||
D03: | DC-control input 0 | 10V control of amplitude and frequency |
D09: | Adjustable current limit with switch-off | |
Options for control unit SyCore | ||
Analyzer 2 channel (voltage and current) | ||
Additional measurements: | – P, W, VA and power factor; – Frequency; – Crest factor; – Oscilloscope function |
|
SyCore – Upgrade (Event-Trigger) | – Oscilloscope trigger signal at voltage interruptions and/or voltage changes; – 2 x trigger inputs for interactive monitoring (pause and break-off) with reply to the software |
|
D09: | Adjustable current limit with switch-off | |
Option for personal computer | ||
GPIB-USB | IEEE 488 Interface type GPIB-USB-HS | Manufacturer: National Instruments |
optionally: | ||
PCI-GPIB: | IEEE 488 Interface type PCI-GPIB | Manufacturer: National Instruments |
optionally: | ||
KPC 488: | IEEE 488 Interface type KPC 488.2 | Manufacturer: Keithley |
Spitzenberger & Spies GmbH & Co. KG Price List | ||
April 8 2013 | ||
Category | Product | Product Descriptions |
Three-Phase Mains Simulation System, Type DM 3000/PAS | ||
A) Power unit | 4-Quadrant Amplifier type PAS 1000 | Pcont:1000VA/Pshort-time:2000VA/Ppeak:6400VA/ V:0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC )/ f:DC … 5kHz(-3dB)/With 4 line display and voltage and current indication/4pad-keyboard for manual control |
B) Control unit | Control unit type SyCore 2M4 | – Basic unit, incl. display, keyboard and incremental unit; – Synthesizer (four-phase – 1MB RAM); – Synthesizer (four-phase – 1MB RAM) incl. adder AD-44; – Multiplier unit four-phase; – IEEE 488 Interface with Bus Isolator; – Software SPS SignalManager for Windows |
C) Housing and integration | 19″-Laboratory rack 24U, movable | Color light Grey (RAL7035)/H=1320mm; W=600mm; D=850mm |
Integration and wiring | Incl. connection panel for contacting the EUT | |
Grid simulator DM 3000/PAS: | ||
Options for 4-Quadrant Amplifier PAS 1000 | ||
06: | Output voltage monitor | (electrically isolated) |
07: | Output current monitor | (electrically isolated) |
10: | Internal resistance compensation | |
11-56Z: | Additional voltage range | V:0 … 56Vrms (±79VDC ) |
11-240Z: | Additional voltage range | V:0 … 240Vrms (±339VDC ) |
11-300: | Special voltages | V:0 … 150Vrms (±212VDC )/0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-300Z: | Special voltage and additional voltage range | V:0 … 60Vrms (±85VDC )/0 … 150Vrms (±212VDC )/ 0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-630DC: | Additional DC-voltage range | V:0 … +630VDC /In combination with option 11-300 or 11-300Z |
13-15: | Special frequency range DC | 15kHz (-3dB) |
13-30: | Special frequency range DC | 30kHz (-3dB) |
17-300: | Floating output | Max. voltage between earth and ground of the output of the amplifier:<300Vrms |
21: | Parallel operation mode (DC … 5kHz) | To increase the output power of an amplifier, up to three similar amplifiers may be connected in parallel |
24-P: | Programmable internal impedance | R:10mΩ … 1Ω/Resolution:10mΩ/ L:10µH … 1.6mH/Resolution:10µH |
28-540/C: | Voltage transformer type UT 20000/540/C | Pcont:20000VA/VInput:0 … 270Vrms / VOutput:0 … 400Vrms /0 … 540Vrms /f:45Hz … 5kHz(-3dB)/ With measurement adaptation to PAS 20000 |
Options for control unit SyCore | ||
1 | SyCore – Upgrade (Event-Trigger) | – Oscilloscope trigger signal at voltage interruptions and/or voltage changes; – 2 x trigger inputs for interactive monitoring (pause and break-off) with reply to the software |
1 | Analyzer 2 channel (voltage and current) | Switch-selectable to phase L1, L2 and L3 |
Additional measurements: | – P, W, VA and power factor; – Frequency; – Crest factor; – Oscilloscope function |
|
D09: | Adjustable current limit with switch-off | |
Option for personal computer | ||
GPIB-USB | IEEE 488 Interface type GPIB-USB-HS | Manufacturer: National Instruments |
optionally: | ||
PCI-GPIB: | IEEE 488 Interface type PCI-GPIB | Manufacturer: National Instruments |
optionally: | ||
KPC 488: | IEEE 488 Interface type KPC 488.2 | Manufacturer: Keithley |
Spitzenberger & Spies GmbH & Co. KG Price List | ||
April 8 2013 | ||
Category | Product | Product Descriptions |
Three-Phase Mains Simulation System, Type DM 7500/PAS | ||
A) Power unit | 4-Quadrant Amplifier type PAS 2500 | Pcont:2500VA/Pshort-time:5000VA/Ppeak:21000VA/ V:0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC )/ f:DC … 5kHz(-3dB)/Incl. one common power supply for all three amplifiers/With 4 line display and voltage and current indication/4pad-keyboard for manual control |
B) Control unit | Control unit type SyCore 2M4 | – Basic unit, incl. display, keyboard and incremental unit; – Synthesizer (four-phase – 1MB RAM); – Synthesizer (four-phase – 1MB RAM) incl. adder AD-44; – Multiplier unit four-phase; – IEEE 488 Interface with Bus Isolator; – Software SPS SignalManager for Windows |
C) Housing and integration | 19″-Laboratory rack 37U, movable | Color light Grey (RAL7035)/H=1920mm; W=600mm; D=850mm |
Integration and wiring | Incl. connection panel for contacting the EUT | |
Grid simulator DM 7500/PAS: | ||
Options for 4-Quadrant Amplifier PAS 2500 | ||
06: | Output voltage monitor | (electrically isolated) |
07: | Output current monitor | (electrically isolated) |
10: | Internal resistance compensation | |
11-33Z: | Additional voltage range | V:0 … 33Vrms (±47VDC ) |
11-56Z: | Additional voltage range | V:0 … 56Vrms (±79VDC ) |
11-240Z: | Additional voltage range | V:0 … 240Vrms (±339VDC ) |
11-300: | Special voltages | V:0 … 150Vrms (±212VDC )/0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-300Z: | Special voltage and additional voltage range | V:0 … 60Vrms (±85VDC )/0 … 150Vrms (±212VDC )/ 0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-630DC: | Additional DC-voltage range | V:0 … +630VDC /In combination with option 11-300 or 11-300Z |
13-15: | Special frequency range DC | 15kHz (-3dB) |
13-30: | Special frequency range DC | 30kHz (-3dB) |
17-300: | Floating output | Max. voltage between earth and ground of the output of the amplifier:<300Vrms |
21: | Parallel operation mode (DC … 5kHz) | To increase the output power of an amplifier, up to three similar amplifiers may be connected in parallel |
24-P: | Programmable internal impedance | R:10mΩ … 1Ω/Resolution:10mΩ/ L:10µH … 1.6mH/Resolution:10µH |
28-540/C: | Voltage transformer type UT 20000/540/C | Pcont:20000VA/VInput:0 … 270Vrms / VOutput:0 … 400Vrms /0 … 540Vrms /f:45Hz … 5kHz(-3dB)/ With measurement adaptation to PAS 20000 |
Options for control unit SyCore | ||
1 | SyCore – Upgrade (Event-Trigger) | – Oscilloscope trigger signal at voltage interruptions and/or voltage changes; – 2 x trigger inputs for interactive monitoring (pause and break-off) with reply to the software |
1 | Analyzer 2 channel (voltage and current) | Switch-selectable to phase L1, L2 and L3 |
Additional measurements: | – P, W, VA and power factor; – Frequency; – Crest factor; – Oscilloscope function |
|
D09: | Adjustable current limit with switch-off | |
Digital Oscilloscope | Digital Real-Time – Oscilloscope, Type TDS 2014/C | 4 channel/100MHz bandwidth/1Gs/s/With IEEE 488 Interface/ 19“-plug-in frame/Incl. matching to software SPS EMC Manufacturer: Tektronix |
Option for personal computer | ||
GPIB-USB | IEEE 488 Interface type GPIB-USB-HS | Manufacturer: National Instruments |
optionally: | ||
PCI-GPIB: | IEEE 488 Interface type PCI-GPIB | Manufacturer: National Instruments |
optionally: | ||
KPC 488: | IEEE 488 Interface type KPC 488.2 | Manufacturer: Keithley |
Spitzenberger & Spies GmbH & Co. KG Price List | ||
April 8 2013 | ||
Category | Product | Product Descriptions |
Three-Phase Mains Simulation System, Type DM 15000/PAS | ||
A) Power unit | 4-Quadrant Amplifier type PAS 5000 | Pcont:5000VA/Pshort-time:10000VA/Ppeak:42000VA/ V:0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC )/ f:DC … 5kHz(-3dB)/Incl. one common power supply for all three amplifiers/With 4 line display and voltage and current indication/4pad-keyboard for manual control |
B) Control unit | Control unit type SyCore 2M4 | – Basic unit, incl. display, keyboard and incremental unit; – Synthesizer (four-phase – 1MB RAM); – Synthesizer (four-phase – 1MB RAM) incl. adder AD-44; – Multiplier unit four-phase; – IEEE 488 Interface with Bus Isolator; – Software SPS SignalManager for Windows |
C) Housing and integration | 19″-Laboratory rack 37U, movable | Color light Grey (RAL7035)/H=1920mm; W=600mm; D=850mm |
Integration and wiring | Incl. connection panel for contacting the EUT | |
Grid simulator DM 7500/PAS: | ||
Options for 4-Quadrant Amplifier PAS 2500 | ||
06: | Output voltage monitor | (electrically isolated) |
07: | Output current monitor | (electrically isolated) |
10: | Internal resistance compensation | |
11-33Z: | Additional voltage range | V:0 … 33Vrms (±47VDC ) |
11-56Z: | Additional voltage range | V:0 … 56Vrms (±79VDC ) |
11-240Z: | Additional voltage range | V:0 … 240Vrms (±339VDC ) |
11-300: | Special voltages | V:0 … 150Vrms (±212VDC )/0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-300Z: | Special voltage and additional voltage range | V:0 … 60Vrms (±85VDC )/0 … 150Vrms (±212VDC )/ 0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-630DC: | Additional DC-voltage range | V:0 … +630VDC /In combination with option 11-300 or 11-300Z |
13-15: | Special frequency range DC | 15kHz (-3dB) |
13-30: | Special frequency range DC | 30kHz (-3dB) |
17-300: | Floating output | Max. voltage between earth and ground of the output of the amplifier:<300Vrms |
21: | Parallel operation mode (DC … 5kHz) | To increase the output power of an amplifier, up to three similar amplifiers may be connected in parallel |
24-P: | Programmable internal impedance | R:10mΩ … 1Ω/Resolution:10mΩ/ L:10µH … 1.6mH/Resolution:10µH |
28-540/C: | Voltage transformer type UT 20000/540/C | Pcont:20000VA/VInput:0 … 270Vrms / VOutput:0 … 400Vrms /0 … 540Vrms /f:45Hz … 5kHz(-3dB)/ With measurement adaptation to PAS 20000 |
Options for control unit SyCore | ||
1 | SyCore – Upgrade (Event-Trigger) | – Oscilloscope trigger signal at voltage interruptions and/or voltage changes; – 2 x trigger inputs for interactive monitoring (pause and break-off) with reply to the software |
1 | Analyzer 2 channel (voltage and current) | Switch-selectable to phase L1, L2 and L3 |
Additional measurements: | – P, W, VA and power factor; – Frequency; – Crest factor; – Oscilloscope function |
|
D09: | Adjustable current limit with switch-off | |
Digital Oscilloscope | Digital Real-Time – Oscilloscope, Type TDS 2014/C | 4 channel/100MHz bandwidth/1Gs/s/With IEEE 488 Interface/ 19“-plug-in frame/Incl. matching to software SPS EMC Manufacturer: Tektronix |
Option for personal computer | ||
GPIB-USB | IEEE 488 Interface type GPIB-USB-HS | Manufacturer: National Instruments |
optionally: | ||
PCI-GPIB: | IEEE 488 Interface type PCI-GPIB | Manufacturer: National Instruments |
optionally: | ||
KPC 488: | IEEE 488 Interface type KPC 488.2 | Manufacturer: Keithley |
Spitzenberger & Spies GmbH & Co. KG Price List | ||
April 8 2013 | ||
Category | Product | Product Descriptions |
Three-Phase Mains Simulation System, Type DM 22500/PAS | ||
A) Power unit | 4-Quadrant Amplifier type PAS 7500 | Pcont:7500VA/Pshort-time:15000VA/Ppeak:63000VA/ V:0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC )/ f:DC … 5kHz(-3dB)/Incl. one common power supply for all three amplifiers/With 4 line display and voltage and current indication/4pad-keyboard for manual control |
B) Control unit | Control unit type SyCore 2M4 | – Basic unit, incl. display, keyboard and incremental unit; – Synthesizer (four-phase – 1MB RAM); – Synthesizer (four-phase – 1MB RAM) incl. adder AD-44; – Multiplier unit four-phase; – IEEE 488 Interface with Bus Isolator; – Software SPS SignalManager for Windows |
C) Housing and integration | 19″-Laboratory rack 37U, movable | Color light Grey (RAL7035)/H=1920mm; W=600mm; D=850mm |
Integration and wiring | Incl. connection panel for contacting the EUT | |
Grid simulator DM 7500/PAS: | ||
Options for 4-Quadrant Amplifier PAS 7500 | ||
06: | Output voltage monitor | (electrically isolated) |
07: | Output current monitor | (electrically isolated) |
10: | Internal resistance compensation | |
11-33Z: | Additional voltage range | V:0 … 33Vrms (±47VDC ) |
11-56Z: | Additional voltage range | V:0 … 56Vrms (±79VDC ) |
11-240Z: | Additional voltage range | V:0 … 240Vrms (±339VDC ) |
11-300: | Special voltages | V:0 … 150Vrms (±212VDC )/0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-300Z: | Special voltage and additional voltage range | V:0 … 60Vrms (±85VDC )/0 … 150Vrms (±212VDC )/ 0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-630DC: | Additional DC-voltage range | V:0 … +630VDC /In combination with option 11-300 or 11-300Z |
13-15: | Special frequency range DC | 15kHz (-3dB) |
17-300: | Floating output | Max. voltage between earth and ground of the output of the amplifier:<300Vrms |
21: | Parallel operation mode (DC … 5kHz) | To increase the output power of an amplifier, up to three similar amplifiers may be connected in parallel |
24-P: | Programmable internal impedance | R:10mΩ … 1Ω/Resolution:10mΩ/ L:10µH … 1.6mH/Resolution:10µH |
28-540/C: | Voltage transformer type UT 20000/540/C | Pcont:20000VA/VInput:0 … 270Vrms / VOutput:0 … 400Vrms /0 … 540Vrms /f:45Hz … 5kHz(-3dB)/ With measurement adaptation to PAS 20000 |
Options for control unit SyCore | ||
1 | SyCore – Upgrade (Event-Trigger) | – Oscilloscope trigger signal at voltage interruptions and/or voltage changes; – 2 x trigger inputs for interactive monitoring (pause and break-off) with reply to the software |
1 | Analyzer 2 channel (voltage and current) | Switch-selectable to phase L1, L2 and L3 |
Additional measurements: | – P, W, VA and power factor; – Frequency; – Crest factor; – Oscilloscope function |
|
D09: | Adjustable current limit with switch-off | |
Digital Oscilloscope | Digital Real-Time – Oscilloscope, Type TDS 2014/C | 4 channel/100MHz bandwidth/1Gs/s/With IEEE 488 Interface/ 19“-plug-in frame/Incl. matching to software SPS EMC Manufacturer: Tektronix |
Option for personal computer | ||
GPIB-USB | IEEE 488 Interface type GPIB-USB-HS | Manufacturer: National Instruments |
optionally: | ||
PCI-GPIB: | IEEE 488 Interface type PCI-GPIB | Manufacturer: National Instruments |
optionally: | ||
KPC 488: | IEEE 488 Interface type KPC 488.2 | Manufacturer: Keithley |
Spitzenberger & Spies GmbH & Co. KG Price List | ||
April 8 2013 | ||
Category | Product | Product Descriptions |
Three-Phase Mains Simulation System, Type DM 30000/PAS | ||
A) Power unit | 4-Quadrant Amplifier type PAS 10000 | Pcont:10000VA/Pshort-time:20000VA/Ppeak:87500VA/ V:0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC )/ f:DC … 5kHz(-3dB)/Incl. one common power supply for all three amplifiers/With 4 line display and voltage and current indication/4pad-keyboard for manual control |
B) Control unit | Control unit type SyCore 2M4 | – Basic unit, incl. display, keyboard and incremental unit; – Synthesizer (four-phase – 1MB RAM); – Synthesizer (four-phase – 1MB RAM) incl. adder AD-44; – Multiplier unit four-phase; – IEEE 488 Interface with Bus Isolator; – Software SPS SignalManager for Windows |
C) Housing and integration | 19″-Laboratory rack 37U, movable | Color light Grey (RAL7035)/H=1920mm; W=600mm; D=850mm |
Integration and wiring | Incl. connection panel for contacting the EUT | |
Grid simulator DM 30000/PAS: | ||
Options for 4-Quadrant Amplifier PAS 10000 | ||
06: | Output voltage monitor | (electrically isolated) |
07: | Output current monitor | (electrically isolated) |
10: | Internal resistance compensation | |
11-33Z: | Additional voltage range | V:0 … 33Vrms (±47VDC ) |
11-56Z: | Additional voltage range | V:0 … 56Vrms (±79VDC ) |
11-240Z: | Additional voltage range | V:0 … 240Vrms (±339VDC ) |
11-300: | Special voltages | V:0 … 150Vrms (±212VDC )/0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-300Z: | Special voltage and additional voltage range | V:0 … 60Vrms (±85VDC )/0 … 150Vrms (±212VDC )/ 0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-630DC: | Additional DC-voltage range | V:0 … +630VDC /In combination with option 11-300 or 11-300Z |
13-15: | Special frequency range DC | 15kHz (-3dB) |
17-300: | Floating output | Max. voltage between earth and ground of the output of the amplifier:<300Vrms |
21: | Parallel operation mode (DC … 5kHz) | To increase the output power of an amplifier, up to three similar amplifiers may be connected in parallel |
24-P: | Programmable internal impedance | R:10mΩ … 1Ω/Resolution:10mΩ/ L:10µH … 1.6mH/Resolution:10µH |
28-540/C: | Voltage transformer type UT 20000/540/C | Pcont:20000VA/VInput:0 … 270Vrms / VOutput:0 … 400Vrms /0 … 540Vrms /f:45Hz … 5kHz(-3dB)/ With measurement adaptation to PAS 20000 |
Options for control unit SyCore | ||
1 | SyCore – Upgrade (Event-Trigger) | – Oscilloscope trigger signal at voltage interruptions and/or voltage changes; – 2 x trigger inputs for interactive monitoring (pause and break-off) with reply to the software |
1 | Analyzer 2 channel (voltage and current) | Switch-selectable to phase L1, L2 and L3 |
Additional measurements: | – P, W, VA and power factor; – Frequency; – Crest factor; – Oscilloscope function |
|
D09: | Adjustable current limit with switch-off | |
Digital Oscilloscope | Digital Real-Time – Oscilloscope, Type TDS 2014/C | 4 channel/100MHz bandwidth/1Gs/s/With IEEE 488 Interface/ 19“-plug-in frame/Incl. matching to software SPS EMC Manufacturer: Tektronix |
Option for personal computer | ||
GPIB-USB | IEEE 488 Interface type GPIB-USB-HS | Manufacturer: National Instruments |
optionally: | ||
PCI-GPIB: | IEEE 488 Interface type PCI-GPIB | Manufacturer: National Instruments |
optionally: | ||
KPC 488: | IEEE 488 Interface type KPC 488.2 | Manufacturer: Keithley |
Spitzenberger & Spies GmbH & Co. KG Price List | ||
April 8 2013 | ||
Category | Product | Product Descriptions |
Three-Phase Mains Simulation System, Type DM 45000/PAS | ||
A) Power unit | 4-Quadrant Amplifier type PAS 15000 | Pcont:15000VA/Pshort-time:30000VA/Ppeak:140000VA/ V:0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC )/ f:DC … 5kHz(-3dB)/With 4 line display and voltage and current indication/4pad-keyboard for manual control |
B) Control unit | Control unit type SyCore 2M4 | – Basic unit, incl. display, keyboard and incremental unit; – Synthesizer (four-phase – 1MB RAM); – Synthesizer (four-phase – 1MB RAM) incl. adder AD-44; – Multiplier unit four-phase; – IEEE 488 Interface with Bus Isolator; – Software SPS SignalManager for Windows |
C) Housing and integration | 19″-Laboratory rack 37U, movable | Color light Grey (RAL7035)/H=1920mm; W=600mm; D=850mm |
Integration and wiring | Incl. connection panel for contacting the EUT | |
Grid simulator DM 45000/PAS: | ||
Options for 4-Quadrant Amplifier PAS 15000 | ||
06: | Output voltage monitor | (electrically isolated) |
07: | Output current monitor | (electrically isolated) |
10: | Internal resistance compensation | |
11-33Z: | Additional voltage range | V:0 … 33Vrms (±47VDC ) |
11-56Z: | Additional voltage range | V:0 … 56Vrms (±79VDC ) |
11-240Z: | Additional voltage range | V:0 … 240Vrms (±339VDC ) |
11-300: | Special voltages | V:0 … 150Vrms (±212VDC )/0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-300Z: | Special voltage and additional voltage range | V:0 … 60Vrms (±85VDC )/0 … 150Vrms (±212VDC )/ 0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-630DC: | Additional DC-voltage range | V:0 … +630VDC /In combination with option 11-300 or 11-300Z |
13-15: | Special frequency range DC | 15kHz (-3dB) |
17-300: | Floating output | Max. voltage between earth and ground of the output of the amplifier:<300Vrms |
21: | Parallel operation mode (DC … 5kHz) | To increase the output power of an amplifier, up to three similar amplifiers may be connected in parallel |
24-P: | Programmable internal impedance | R:10mΩ … 1Ω/Resolution:10mΩ/ L:10µH … 1.6mH/Resolution:10µH |
28-540/C: | Voltage transformer type UT 20000/540/C | Pcont:20000VA/VInput:0 … 270Vrms / VOutput:0 … 400Vrms /0 … 540Vrms /f:45Hz … 5kHz(-3dB)/ With measurement adaptation to PAS 20000 |
Options for control unit SyCore | ||
1 | SyCore – Upgrade (Event-Trigger) | – Oscilloscope trigger signal at voltage interruptions and/or voltage changes; – 2 x trigger inputs for interactive monitoring (pause and break-off) with reply to the software |
1 | Analyzer 2 channel (voltage and current) | Switch-selectable to phase L1, L2 and L3 |
Additional measurements: | – P, W, VA and power factor; – Frequency; – Crest factor; – Oscilloscope function |
|
D09: | Adjustable current limit with switch-off | |
Digital Oscilloscope | Digital Real-Time – Oscilloscope, Type TDS 2014/C | 4 channel/100MHz bandwidth/1Gs/s/With IEEE 488 Interface/ 19“-plug-in frame/Incl. matching to software SPS EMC Manufacturer: Tektronix |
Option for personal computer | ||
GPIB-USB | IEEE 488 Interface type GPIB-USB-HS | Manufacturer: National Instruments |
optionally: | ||
PCI-GPIB: | IEEE 488 Interface type PCI-GPIB | Manufacturer: National Instruments |
optionally: | ||
KPC 488: | IEEE 488 Interface type KPC 488.2 | Manufacturer: Keithley |
Spitzenberger & Spies GmbH & Co. KG Price List | ||
April 8 2013 | ||
Category | Product | Product Descriptions |
Three-Phase Mains Simulation System, Type DM 60000/PAS | ||
A) Power unit | 4-Quadrant Amplifier type PAS 20000 | Pcont:20000VA/Pshort-time:40000VA/Ppeak:200000VA/ V:0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC )/ f:DC … 5kHz(-3dB)/Incl. one common power supply for all three amplifiers/With 4 line display and voltage and current indication/4pad-keyboard for manual control |
B) Control unit | Control unit type SyCore 2M4 | – Basic unit, incl. display, keyboard and incremental unit; – Synthesizer (four-phase – 1MB RAM); – Synthesizer (four-phase – 1MB RAM) incl. adder AD-44; – Multiplier unit four-phase; – IEEE 488 Interface with Bus Isolator; – Software SPS SignalManager for Windows |
C) Housing and integration | 19″-Laboratory rack 42U, with forklift movable | Color light Grey (RAL7035)/H=2120mm; W=600mm; D=1050mm |
Integration and wiring | Incl. connection panel for contacting the EUT | |
Grid simulator DM 60000/PAS: | ||
Options for 4-Quadrant Amplifier PAS 20000 | ||
06: | Output voltage monitor | (electrically isolated) |
07: | Output current monitor | (electrically isolated) |
10: | Internal resistance compensation | |
11-33Z: | Additional voltage range | V:0 … 33Vrms (±47VDC ) |
11-56Z: | Additional voltage range | V:0 … 56Vrms (±79VDC ) |
11-240Z: | Additional voltage range | V:0 … 240Vrms (±339VDC ) |
11-300: | Special voltages | V:0 … 150Vrms (±212VDC )/0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-300Z: | Special voltage and additional voltage range | V:0 … 60Vrms (±85VDC )/0 … 150Vrms (±212VDC )/ 0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-630DC: | Additional DC-voltage range | V:0 … +630VDC /In combination with option 11-300 or 11-300Z |
13-15: | Special frequency range DC | 15kHz (-3dB) |
17-300: | Floating output | Max. voltage between earth and ground of the output of the amplifier:<300Vrms |
21: | Parallel operation mode (DC … 5kHz) | To increase the output power of an amplifier, up to three similar amplifiers may be connected in parallel |
24-P: | Programmable internal impedance | R:10mΩ … 1Ω/Resolution:10mΩ/ L:10µH … 1.6mH/Resolution:10µH |
28-540/C: | Voltage transformer type UT 20000/540/C | Pcont:20000VA/VInput:0 … 270Vrms / VOutput:0 … 400Vrms /0 … 540Vrms /f:45Hz … 5kHz(-3dB)/ With measurement adaptation to PAS 20000 |
Options for control unit SyCore | ||
1 | SyCore – Upgrade (Event-Trigger) | – Oscilloscope trigger signal at voltage interruptions and/or voltage changes; – 2 x trigger inputs for interactive monitoring (pause and break-off) with reply to the software |
1 | Analyzer 2 channel (voltage and current) | Switch-selectable to phase L1, L2 and L3 |
Additional measurements: | – P, W, VA and power factor; – Frequency; – Crest factor; – Oscilloscope function |
|
D09: | Adjustable current limit with switch-off | |
Digital Oscilloscope | Digital Real-Time – Oscilloscope, Type TDS 2014/C | 4 channel/100MHz bandwidth/1Gs/s/With IEEE 488 Interface/ 19“-plug-in frame/Incl. matching to software SPS EMC Manufacturer: Tektronix |
Option for personal computer | ||
GPIB-USB | IEEE 488 Interface type GPIB-USB-HS | Manufacturer: National Instruments |
optionally: | ||
PCI-GPIB: | IEEE 488 Interface type PCI-GPIB | Manufacturer: National Instruments |
optionally: | ||
KPC 488: | IEEE 488 Interface type KPC 488.2 | Manufacturer: Keithley |
Spitzenberger & Spies GmbH & Co. KG Price List | ||
April 8 2013 | ||
Category | Product | Product Descriptions |
Three-Phase Mains Simulation System, Type DM 75000/PAS | ||
A) Power unit | 4-Quadrant Amplifier type PAS 25000 | Pcont:25000VA/Pshort-time:50000VA/Ppeak:210000VA/ V:0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC )/ f:DC … 5kHz(-3dB)/Incl. one common power supply for all three amplifiers/With 4 line display and voltage and current indication/4pad-keyboard for manual control |
B) Control unit | Control unit type SyCore 2M4 | – Basic unit, incl. display, keyboard and incremental unit; – Synthesizer (four-phase – 1MB RAM); – Synthesizer (four-phase – 1MB RAM) incl. adder AD-44; – Multiplier unit four-phase; – IEEE 488 Interface with Bus Isolator; – Software SPS SignalManager for Windows |
C) Housing and integration | 19″-Laboratory rack 42U, with forklift movable | Color light Grey (RAL7035)/H=2120mm; W=600mm; D=1050mm |
19″-Laboratory rack 42U, with forklift movable | Color light Grey (RAL7035)/H=2120mm; W=800mm; D=1050mm | |
Integration and wiring | Incl. connection panel for contacting the EUT | |
Grid simulator DM 75000/PAS: | ||
Options for 4-Quadrant Amplifier PAS 25000 | ||
06: | Output voltage monitor | (electrically isolated) |
07: | Output current monitor | (electrically isolated) |
10: | Internal resistance compensation | |
11-33Z: | Additional voltage range | V:0 … 33Vrms (±47VDC ) |
11-56Z: | Additional voltage range | V:0 … 56Vrms (±79VDC ) |
11-240Z: | Additional voltage range | V:0 … 240Vrms (±339VDC ) |
11-300: | Special voltages | V:0 … 150Vrms (±212VDC )/0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-300Z: | Special voltage and additional voltage range | V:0 … 60Vrms (±85VDC )/0 … 150Vrms (±212VDC )/ 0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-630DC: | Additional DC-voltage range | V:0 … +630VDC /In combination with option 11-300 or 11-300Z |
13-15: | Special frequency range DC | 15kHz (-3dB) |
17-300: | Floating output | Max. voltage between earth and ground of the output of the amplifier:<300Vrms |
21: | Parallel operation mode (DC … 5kHz) | To increase the output power of an amplifier, up to three similar amplifiers may be connected in parallel |
24-P: | Programmable internal impedance | R:10mΩ … 1Ω/Resolution:10mΩ/ L:10µH … 1.6mH/Resolution:10µH |
28-540/C: | Voltage transformer type UT 20000/540/C | Pcont:20000VA/VInput:0 … 270Vrms / VOutput:0 … 400Vrms /0 … 540Vrms /f:45Hz … 5kHz(-3dB)/ With measurement adaptation to PAS 20000 |
Options for control unit SyCore | ||
1 | SyCore – Upgrade (Event-Trigger) | – Oscilloscope trigger signal at voltage interruptions and/or voltage changes; – 2 x trigger inputs for interactive monitoring (pause and break-off) with reply to the software |
1 | Analyzer 2 channel (voltage and current) | Switch-selectable to phase L1, L2 and L3 |
Additional measurements: | – P, W, VA and power factor; – Frequency; – Crest factor; – Oscilloscope function |
|
D09: | Adjustable current limit with switch-off | |
Digital Oscilloscope | Digital Real-Time – Oscilloscope, Type TDS 2014/C | 4 channel/100MHz bandwidth/1Gs/s/With IEEE 488 Interface/ 19“-plug-in frame/Incl. matching to software SPS EMC Manufacturer: Tektronix |
Option for personal computer | ||
GPIB-USB | IEEE 488 Interface type GPIB-USB-HS | Manufacturer: National Instruments |
optionally: | ||
PCI-GPIB: | IEEE 488 Interface type PCI-GPIB | Manufacturer: National Instruments |
optionally: | ||
KPC 488: | IEEE 488 Interface type KPC 488.2 | Manufacturer: Keithley |
Spitzenberger & Spies GmbH & Co. KG Price List | ||
April 8 2013 | ||
Category | Product | Product Descriptions |
Three-Phase Mains Simulation System, Type DM 90000/PAS | ||
A) Power unit | 4-Quadrant Amplifier type PAS 30000 | Pcont:30000VA/Pshort-time:60000VA/Ppeak:252000VA/ V:0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC )/ f:DC … 5kHz(-3dB)/Incl. one common power supply for all three amplifiers/With 4 line display and voltage and current indication/4pad-keyboard for manual control |
B) Control unit | Control unit type SyCore 2M4 | – Basic unit, incl. display, keyboard and incremental unit; – Synthesizer (four-phase – 1MB RAM); – Synthesizer (four-phase – 1MB RAM) incl. adder AD-44; – Multiplier unit four-phase; – IEEE 488 Interface with Bus Isolator; – Software SPS SignalManager for Windows |
C) Housing and integration | 19″-Laboratory rack 46U, with forklift movable | Color light Grey (RAL7035)/H=2320mm; W=600mm; D=1050mm |
19″-Laboratory rack 46U, with forklift movable | Color light Grey (RAL7035)/H=2320mm; W=800mm; D=1050mm | |
Integration and wiring | Incl. connection panel for contacting the EUT | |
Grid simulator DM 90000/PAS: | ||
Options for 4-Quadrant Amplifier PAS 30000 | ||
06: | Output voltage monitor | (electrically isolated) |
07: | Output current monitor | (electrically isolated) |
10: | Internal resistance compensation | |
11-33Z: | Additional voltage range | V:0 … 33Vrms (±47VDC ) |
11-56Z: | Additional voltage range | V:0 … 56Vrms (±79VDC ) |
11-240Z: | Additional voltage range | V:0 … 240Vrms (±339VDC ) |
11-300: | Special voltages | V:0 … 150Vrms (±212VDC )/0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-300Z: | Special voltage and additional voltage range | V:0 … 60Vrms (±85VDC )/0 … 150Vrms (±212VDC )/ 0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-630DC: | Additional DC-voltage range | V:0 … +630VDC /In combination with option 11-300 or 11-300Z |
17-300: | Floating output | Max. voltage between earth and ground of the output of the amplifier:<300Vrms |
21: | Parallel operation mode (DC … 5kHz) | To increase the output power of an amplifier, up to three similar amplifiers may be connected in parallel |
24-P: | Programmable internal impedance | R:10mΩ … 1Ω/Resolution:10mΩ/ L:10µH … 1.6mH/Resolution:10µH |
28-540/C: | Voltage transformer type UT 20000/540/C | Pcont:20000VA/VInput:0 … 270Vrms / VOutput:0 … 400Vrms /0 … 540Vrms /f:45Hz … 5kHz(-3dB)/ With measurement adaptation to PAS 20000 |
Options for control unit SyCore | ||
1 | SyCore – Upgrade (Event-Trigger) | – Oscilloscope trigger signal at voltage interruptions and/or voltage changes; – 2 x trigger inputs for interactive monitoring (pause and break-off) with reply to the software |
1 | Analyzer 2 channel (voltage and current) | Switch-selectable to phase L1, L2 and L3 |
Additional measurements: | – P, W, VA and power factor; – Frequency; – Crest factor; – Oscilloscope function |
|
D09: | Adjustable current limit with switch-off | |
Digital Oscilloscope | Digital Real-Time – Oscilloscope, Type TDS 2014/C | 4 channel/100MHz bandwidth/1Gs/s/With IEEE 488 Interface/ 19“-plug-in frame/Incl. matching to software SPS EMC Manufacturer: Tektronix |
Option for personal computer | ||
GPIB-USB | IEEE 488 Interface type GPIB-USB-HS | Manufacturer: National Instruments |
optionally: | ||
PCI-GPIB: | IEEE 488 Interface type PCI-GPIB | Manufacturer: National Instruments |
optionally: | ||
KPC 488: | IEEE 488 Interface type KPC 488.2 | Manufacturer: Keithley |
Spitzenberger & Spies GmbH & Co. KG Price List | ||
April 8 2013 | ||
Category | Product | Product Descriptions |
Three-Phase Mains Simulation System, Type DM 120000/PAS | ||
A) Power unit | 4-Quadrant Amplifier type PAS 40000 | Pcont:40000VA/Pshort-time:80000VA/Ppeak:400000VA/ V:0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC )/ f:DC … 5kHz(-3dB)/With 4 line display and voltage and current indication/4pad-keyboard for manual control |
B) Control unit | Control unit type SyCore 2M4 | – Basic unit, incl. display, keyboard and incremental unit; – Synthesizer (four-phase – 1MB RAM); – Synthesizer (four-phase – 1MB RAM) incl. adder AD-44; – Multiplier unit four-phase; – IEEE 488 Interface with Bus Isolator; – Software SPS SignalManager for Windows |
C) Housing and integration | 19″-Laboratory rack 46U, with forklift movable | Color light Grey (RAL7035)/H=2320mm; W=600mm; D=1050mm |
19″-Laboratory rack 42U, with forklift movable | Color light Grey (RAL7035)/H=2120mm; W=600mm; D=1050mm | |
19″-Laboratory rack 42U, with forklift movable | Color light Grey (RAL7035)/H=2120mm; W=800mm; D=1050mm | |
Integration and wiring | Incl. connection panel for contacting the EUT | |
Grid simulator DM 90000/PAS: | ||
Options for 4-Quadrant Amplifier PAS 40000 | ||
06: | Output voltage monitor | (electrically isolated) |
07: | Output current monitor | (electrically isolated) |
10: | Internal resistance compensation | |
11-33Z: | Additional voltage range | V:0 … 33Vrms (±47VDC ) |
11-56Z: | Additional voltage range | V:0 … 56Vrms (±79VDC ) |
11-240Z: | Additional voltage range | V:0 … 240Vrms (±339VDC ) |
11-300: | Special voltages | V:0 … 150Vrms (±212VDC )/0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-300Z: | Special voltage and additional voltage range | V:0 … 60Vrms (±85VDC )/0 … 150Vrms (±212VDC )/ 0 … 300Vrms (±424VDC )/Replaces standard range 0 … 135Vrms (±191VDC )/0 … 270Vrms (±382VDC ) |
11-630DC: | Additional DC-voltage range | V:0 … +630VDC /In combination with option 11-300 or 11-300Z |
17-300: | Floating output | Max. voltage between earth and ground of the output of the amplifier:<300Vrms |
21: | Parallel operation mode (DC … 5kHz) | To increase the output power of an amplifier, up to three similar amplifiers may be connected in parallel |
24-P: | Programmable internal impedance | R:10mΩ … 1Ω/Resolution:10mΩ/ L:10µH … 1.6mH/Resolution:10µH |
28-540/C: | Voltage transformer type UT 20000/540/C | Pcont:20000VA/VInput:0 … 270Vrms / VOutput:0 … 400Vrms /0 … 540Vrms /f:45Hz … 5kHz(-3dB)/ With measurement adaptation to PAS 20000 |
Options for control unit SyCore | ||
1 | SyCore – Upgrade (Event-Trigger) | – Oscilloscope trigger signal at voltage interruptions and/or voltage changes; – 2 x trigger inputs for interactive monitoring (pause and break-off) with reply to the software |
1 | Analyzer 2 channel (voltage and current) | Switch-selectable to phase L1, L2 and L3 |
Additional measurements: | – P, W, VA and power factor; – Frequency; – Crest factor; – Oscilloscope function |
|
D09: | Adjustable current limit with switch-off | |
Digital Oscilloscope | Digital Real-Time – Oscilloscope, Type TDS 2014/C | 4 channel/100MHz bandwidth/1Gs/s/With IEEE 488 Interface/ 19“-plug-in frame/Incl. matching to software SPS EMC Manufacturer: Tektronix |
Option for personal computer | ||
GPIB-USB | IEEE 488 Interface type GPIB-USB-HS | Manufacturer: National Instruments |
optionally: | ||
PCI-GPIB: | IEEE 488 Interface type PCI-GPIB | Manufacturer: National Instruments |
optionally: | ||
KPC 488: | IEEE 488 Interface type KPC 488.2 | Manufacturer: Keithley |