Reliant EMC

V-LISN CISPR 16-1-2

Schwarzbeck Family of V-LISN's for CISPR 16-1-2
· NSLK 8117 2 path V-LISN, 9kHz - 30MHz
· NNLK 8121 V-LISN 9kHz-30MHz
· NSLK 8122 V-LISN 9kHz-30MHz
· NSLK 8126 V-LISN 9kHz-30MHz
· NSLK 8127 V-LISN 9kHz-30MHz
· NSLK 8128 V-LISN 9kHz-30MHz
· NNLK 8129 V-LISN (9kHz) 150kHz-30MHz
· NNLK 8129-2 HV V-LISN (9kHz) 150kHz-30MHz
· NNLK 8130 V-LISN (9) 150kHz-30MHz
· NNLK 8140 Single Path V-LISN (9) 150kHz–30MHz
· NSLK 8163 V-LISN 9kHz-30MHz
 
· Calibration adapters for V-LISN (V-AMN)

 

NSLK 8117 2 path V-LISN, 9kHz - 30MHz
Schwarzbeck V-LISN NSLK 8117

Schwarzbeck V-LISN NSLK 8117 - Rear View

· 2 path V-LISN, 9kHz - 30MHz
· 50 µH + 5 Ohm || 50 Ohm
· 2 x 16 A Schuko socket
· 4mm banana socket connector for Artificial Hand
· BNC Socket Connector to EMI Receiver
 

Schwarzbeck V-LISN NSLK 8117 Data Sheet NSLK 8117

 

NNLK 8121 V-LISN 9kHz-30MHz
Schwarzbeck V-LISN NNLK 8121
 
Schwarzbeck V-LISN NNLK 8121 
· V-LISN
· 9 kHz - 30 MHz
· 50 µH + 5 Ohm || 50 Ohm
· 4 x 50 (100) A
· wing terminals
(For continuously 100 A add the options cont. high current and cooling fans!)
 
Schwarzbeck V-LISN NSLK 8126 Data Sheet Data Sheet NNLK 8121
Schwarzbeck V-LISN NSLK 8126 Operating Time as a Function of CURRENT Data Sheet NSLK 8126 Operating Time as a Function of CURRENT Data Sheet
 
Options:
Option RC:
Option RC for LISN: Remote Control with built in power supply. LISN can be controlled by R&S or Schwarzbeck code, including remote control cable for your receiver type (Please specify your receiver type!). LISN can be selected from the R&S receiver menu or in the EMC32 software like an R&S LISN. No programming of the user interface necessary. Functions: path selection and PE grounded or via choke.
 
Schwarzbeck NSLK NNLK 81xx LISN with Option RC for EMI Measurement Receivers Data Sheet NSLK NNLK 81xx LISN with Option RC for EMI Measurement Receivers Data Sheet
 
Opt. PLC:
Option: Power Line Communication, according to EN 50065-1, selectable ranges: 3 - 9 kHz, 9 - 95 kHz, 95 kHz - 30 MHz.
 
Schwarzbeck Artificial Mains NSLK 8127 with option PLC Data Sheet Artificial Mains NSLK 8127 with option PLC Data Sheet

 

Option Hochstrom
Option: cont. high current, additional terminals to bypass
the 250 µH pre-filter chokes, provides less voltage drop
and less heating.
 
Schwarzbeck NNLK 8121 Option Continuous High Current  Data Sheet NNLK 8121 Option Hochstrom
 
Option 400/700V
Option: 400/700 V Voltage to Neutral / Voltage between lines
 
Option Lüfter
Option: Cooling Fans
 
Option TC
The temperature monitor module which is optional available for the NNLK LISN warns the user optical and acoustical when the temperature pets too high. It controls the fans of the LISN temperature-dependent, too and thus prevents overheating. If the critical temperature of 115°C is reached the temperature control module indicates this optical and acoustical.
 
Schwarzbeck V-LISN NNLK Temperature Monitor Module Data Sheet NNLK Temperature Monitor Module Data Sheet

 

NSLK 8122 V-LISN 9kHz-30MHz
Schwarzbeck V-LISN NNLK 8122
 
 
· Topology: V-LISN
· Frequency Range: 9 kHz - 30 MHz
· Pre-filter choke: 250 µH
· Impedance simulation: 50 Ω || (50 µH + 5 Ω)
· Max. Voltage: 1000 VDC 750 VAC 50/60 Hz
· Max. Current: 50 A

 

 
Schwarzbeck V-LISN NSLK 8126 Data Sheet Data Sheet NSLK 8122
 

 

 

NSLK 8126 V-LISN 9kHz-30MHz
Schwarzbeck V-LISN NSLK 8126
· V-LISN
· 9 kHz - 30 MHz
· 50 µH + 5 Ohm || 50 Ohm
· 4 x 16/25 A
· 2 x 16 A Schuko and 4 x 16 A CEKON socket
· Artificial Hand
 

Schwarzbeck V-LISN NSLK 8126 Operating Manual Schwarzbeck V-LISN NSLK 8126 Operating Manual

 
Options:
Option RC:
Option RC for LISN: Remote Control with built in power supply. LISN can be controlled by R&S or Schwarzbeck code, including remote control cable for your receiver type (Please specify your receiver type!). LISN can be selected from the R&S receiver menu or in the EMC32 software like an R&S LISN. No programming of the user interface necessary. Functions: path selection and PE grounded or via choke.
 

Schwarzbeck NSLK NNLK 81xx LISN with Option RC for EMI Measurement Receivers Data Sheet NSLK 8126 Option RC

 

NSLK 8127 V-LISN 9kHz-30MHz
Schwarzbeck V-LISN NSLK 8127
· V-LISN, 9 kHz - 30 MHz
· 50 µH + 5 Ohm || 50 Ohm
· 2 x 16 A Schuko socket
· Artificial Hand
 

Schwarzbeck V-LISN NSLK 8127 Data Sheet NSLK 8127

 
Options:
Option RC:
Option RC for LISN: Remote Control with built in power supply. LISN can be controlled by R&S or Schwarzbeck code, including remote control cable for your receiver type (Please specify your receiver type!). LISN can be selected from the R&S receiver menu or in the EMC32 software like an R&S LISN. No programming of the user interface necessary. Functions: path selection and PE grounded or via choke.
 

Schwarzbeck NSLK NNLK 81xx LISN with option RC for EMI measurement receivers NSLK 8127 Option RC

 
 Option PLC:
Option: Power Line Communication, according to EN 50065-1, selectable ranges: 3 - 9 kHz, 9 - 95 kHz, 95 kHz - 30 MHz.
 

Schwarzbeck Artificial Mains NSLK 8127 with option PLC NSLK 8127 Option PLC

 

NSLK 8128 V-LISN 9kHz-30MHz
Schwarzbeck V-LISN NSLK 8128
· V-LISN, 9 kHz - 30 MHz
· 50 µH + 5 Ohm || 50 Ohm
· 4 x 32/50 A
· 2 x 16 A Schuko and 4 x 32 A CEKON socket
· Artificial Hand
 

Schwarzbeck V-LISN NSLK 8128 Data Sheet Data Sheet NSLK 8128

 
Options:
Option RC:
Option RC for LISN: Remote Control with built in power supply. LISN can be controlled by R&S or Schwarzbeck code, including remote control cable for your receiver type (Please specify your receiver type!). LISN can be selected from the R&S receiver menu or in the EMC32 software like an R&S LISN. No programming of the user interface necessary. Functions: path selection and PE grounded or via choke.
 

Schwarzbeck NSLK NNLK 81xx LISN with Option RC for EMI Measurement Receivers Data Sheet NSLK 8128 Option RC Data Sheet

 

NNLK 8129 V-LISN (9) 150kHz-30MHz
Schwarzbeck V-LISN NNLK 8129 
· V-LISN
· (9) 150 kHz - 30 MHz
· 50 µH || 50 Ohm
· 4 x 200 (300) A
· wing terminals
· low voltage drop.
 
Schwarzbeck V-LISN NNLK 8129 Data Sheet Data Sheet NNLK 8129
Schwarzbeck A Circuit Diagram RF Section Data Sheet A Circuit Diagram RF Section Data Sheet
 
Options:
Option RC:
Option RC for LISN: Remote Control with built in power supply. LISN can be controlled by R&S or Schwarzbeck code, including remote control cable for your receiver type (Please specify your receiver type!). LISN can be selected from the R&S receiver menu or in the EMC32 software like an R&S LISN. No programming of the user interface necessary. Functions: path selection and PE grounded or via choke. 
 
Schwarzbeck NSLK NNLK 81xx LISN with Option RC for EMI Measurement Receivers Data Sheet NSLK NNLK 81xx LISN with Option RC for EMI Measurement Receivers Data Sheet
 
Option 400/700V:
400/700 V Voltage to Neutral / Voltage between lines
 
Option Lüfter:
Cooling Fans
 
Option TC
The temperature monitor module which is optional available for the NNLK LISN warns the user optical and acoustical when the temperature pets too high. It controls the fans of the LISN temperature-dependent, too and thus prevents overheating. If the critical temperature of 115°C is reached the temperature control module indicates this optical and acoustical.
 
Schwarzbeck V-LISN NNLK Temperature Monitor Module Data Sheet NNLK Temperature Monitor Module Data Sheet
 
NNLK 8129-2 HV - LISN (9kHz) 150kHz-30MHz

Schwarzbeck NNLK 8129-2 HV LISN

Schwarzbeck NNLK 8129-2 HV LISN Rear

Topology:
V-LISN
Frequency Range:
(9 kHz) 150 kHz - 30 MHz
Impedance simulation:
50 µH || 50 Ω
Max. Voltage:
1000 VAC 50/60 Hz
1000 VDC
Max. Current: 
2 x 200 (300) A 
 
Mains terminals:
Wing terminals 12 mm, removable
 
Terminals for E.u.T.:
Wing terminals 12 mm, removable
 
Length:
520 mm
 
Width:
445 mm
 
Height:
385 mm
 
Weight:
~22 kg
 
Standard:
CISPR 16-1-2
Schwarzbeck V-LISN NNLK 8130 Data Sheet Data Sheet NNLK 8129-2 HV

 

Option RC for LISN:
Remote Control with built in power supply. LISN can be controlled by R&S or Schwarzbeck code, including remote control cable for your receiver type (Please specify your receiver type!). LISN can be selected from the R&S receiver menu or in the EMC32 software like an R&S LISN. No programming of the user interface necessary. Functions: path selection and PE grounded or via choke.
Schwarzbeck V-LISN NNLK 8130 Data Sheet Option RC for NNLK 8129-2 HV LISN

 

Option TC for LISN:
The temperature monitor modul which is optional available for the NNLK LISN warns the user optical and acoustical when the temperature gets too high. It controls the fans of the LISN temperature-dependent, too and thus prevents overheating. If a critical temperature is reached the temperature control modul indicates this optically and acoustically.
Schwarzbeck V-LISN NNLK 8130 Data Sheet Option TC for NNLK 8129-2 HV LISN

 

NNLK 8130 V-LISN (9kHz) 150kHz-30MHz
Schwarzbeck V-LISN NNLK 8130
 
Schwarzbeck V-LISN NNLK 8130 
· V-LISN
· (9) 150 kHz - 30 MHz
· 50 µH || 50 Ohm
· 4 x 400 (500) A
· wing terminals
· low voltage drop
· cooling fans
 
Schwarzbeck V-LISN NNLK 8130 Data Sheet Data Sheet NNLK 8130
Schwarzbeck A Circuit Diagram RF Section Data Sheet A Circuit Diagram RF Section Data Sheet
 
Options:
Option RC
Option RC for LISN: Remote Control with built in power supply. LISN can be controlled by R&S or Schwarzbeck code, including remote control cable for your receiver type (Please specify your receiver type!). LISN can be selected from the R&S receiver menu or in the EMC32 software like an R&S LISN. No programming of the user interface necessary. Functions: path selection and PE grounded or via choke.
 
Schwarzbeck NSLK NNLK 81xx LISN with Option RC for EMI Measurement Receivers Data Sheet NSLK NNLK 81xx LISN with Option RC for EMI Measurement Receivers Data Sheet
 
Option TC
The temperature monitor module which is optional available for the NNLK LISN warns the user optical and acoustical when the temperature pets too high. It controls the fans of the LISN temperature-dependent, too and thus prevents overheating. If the critical temperature of 115°C is reached the temperature control module indicates this optical and acoustical.
 
Schwarzbeck V-LISN NNLK Temperature Monitor Module Data Sheet NNLK Temperature Monitor Module Data Sheet

 

NNLK 8140 Single Path V-LISN (9) 150kHz–30MHz
Schwarzbeck V-LISN NNLK 8140
Schwarzbeck V-LISN NNLK 8140 
· Single Path V-LISN
· (9) 150 kHz – 30 MHz
· 50 µH || 50 Ohm
· 1 x 800 A continuously (1000 A short time)
· wing terminals
· low voltage drop
· High power resistors
· cooling fans.
· Max. Voltage: 1000 V DC or 650 V AC 50/60 Hz.
 
Schwarzbeck CISPR 16-1-2 High Current High Voltage V-LISN NNLK Data Sheet CISPR 16-1-2 High Current High Voltage V-LISN NNLK Data Sheet
 
 
Option TC
 
The temperature monitor module which is optional available for the NNLK LISN warns the user optical and acoustical when the temperature pets too high. It controls the fans of the LISN temperature-dependent, too and thus prevents overheating. If the critical temperature of 115°C is reached the temperature control module indicates this optical and acoustical.
 
Schwarzbeck V-LISN NNLK Temperature Monitor Module Data Sheet NNLK Temperature Monitor Module Data Sheet

 

NSLK 8163 9KHz–30MHz

Schwarzbeck LISN NSLK 8163

Schwarzbeck NSLK 8163 Back

Topology
V-LISN
Frequency Range:
9 kHz - 30 MHz
Pre-filter choke:
250 µH
Impedance simulation:
50 Ω || (50 µH + 5 Ω)
Max. continuous current CEE:
4 x 63 A
max. Voltage:
400 / 700 VAC
630 VDC
Supply cable:
CEE plug (IEC 60309)
Connector for EuT:
CEE socket (IEC 60309  3L+N+PE 63 A)
Connector for "artificial hand":
4 mm laboratory socket with screw terminal 6 mm,
not removable
Connector to EMI-receiver:
BNC socked, 50 Ω
 
 
Length:
650 mm
Width:
450 mm
Height:
480 mm
Weight:
40.8 kg
 
 
Standard:
CISPR 16-1-2

 

Schwarzbeck V-LISN NNLK Temperature Monitor Module Data Sheet NSLK 8163 Data Sheet

 

Options:
Opt. RC:
Option RC for LISN: Remote Control with built in power supply. LISN can be controlled by R&S or Schwarzbeck code, including remote control cable for your receiver type (Please specify your receiver type!). LISN can be selected from the R&S receiver menu or in the EMC32 software like an R&S LISN. No programming of the user interface necessary. Functions: path selection and PE grounded or via choke.

 

Schwarzbeck V-LISN NNLK Temperature Monitor Module Data Sheet LISN NSLK 8163 RC Option Data Sheet

 

Calibration adapters for V-LISN (V-AMN)
KA 8127 
BNC female to Schuko male. Fits for all LISN types with Schuko socket. e.g. NSLK 8127, NSLK 8126, NSLK 8128, R&S ESH3-Z5, ENV216 
KA 8127 female 
BNC female to Schuko female. Fits for all LISN types with Schuko plug. e.g. NSLK 8127, R&S ESH3-Z5, ENV216 
KA 8126 
BNC female to CEE / CEKON 16 A male. Fits for all LISN with 16 A three-phase socket e.g. NSLK 8126. Diameter of Phase/Neutral rods: 5 mm. Diameter of Earth rod: 6,9 mm. 
KA 8126 female 
BNC female to CEE / CEKON 16 A female. Fits for all LISN with 16 A three-phase CEE /CEKON plug, e.g. NSLK 8126. Inner diameter of Phase/Neutral rods: 5 mm. Inner diameter of Earth rod: 6,9 mm. 
KA 8128 
BNC female to CEE / CEKON 32 A male. Fits for all LISN with 32 A CEE / CEKON three-phase socket e.g. NSLK 8128, R&S ENV432. Diameter of Phase/Neutral rods: 5,9 mm. Diameter of Earth rod: 8 mm. 
KA 8128 female 
BNC female to CEE / CEKON 32 A female. Fits for all LISN with 32 A three-phase CEE / CEKON plug, e.g. NSLK 8128, R&S ENV432. Inner diameter of Phase/Neutral rods: 5,9 mm. Inner Diameter of Earth rod: 8 mm 
KA 8163 
BNC female to CEE / CEKON 63 A male. Fits for all LISN with 63 A three-phase socket, e.g. NSLK 8163. Diameter of Phase/Neutral rods: 8 mm. Diameter of Earth rod: 10 mm 
KA 8163 female 
BNC female to CEE / CEKON 63 A female. Fits for all LISN with 63 A three-phase CEE / CEKON plug, e.g. NSLK 8163 Inner diameter of Phase/Neutral rods: 8 mm. Inner diameter of Earth rod: 10 mm 
KA 8121 
BNC female to 4 mm banana plug. Fits for NNLK 8121, NSLK 8122 and NDTV 8160. 
KA 8129 
BNC female to 4 mm banana plug. Fits for NNLK 8129. 
KA 8130 
BNC female to 4 mm banana plug. Fits for NNLK 8130, NNBL 8230, NNBL 8240 and NNLK 8140. 
KA 8125 
BNC female to wing terminals. Fits for NNBM 8124, NNBM 8125, NNBM 8126 A, NNBM 8125 BCI and NNBL 8225, NNHV 8123, NPLC 8500. Diameter of terminals: 8,5 mm, distance of terminals: 60 mm 
KA 8126 D 
BNC female to wing terminals. Fits for NNBM 8126 D, NNBL 8226-HV, NNBL 8226, NNBL 8226-2, NNBM 8125 BCI with Option 200 A, NNBM 8124-200, NNBM 8126 G, NNHV 8123-200. Diameter of terminals: 8,5 mm, distance of terminals: 90 mm 
KA 8126 F 
BNC female to wing terminals. Fits for NNBM 8126 E, NNBM 8126 F, NNBM 8126 F HYB up to S/N 148. Diameter of terminals: 12,4 mm, distance of terminals: 90 mm 
KA 8126 F HYB 
BNC female to wing terminals. Fits for NNBM 8124-400, NNBM 8124-800, NNBL 8229 HV, NNBM 8126 F HYB starting from S/N 149, NNHV 8123-400. Diameter of terminals: 16,4 mm, distance of terminals: 110 mm 
MSS 9630 
Braid current blocking cable to avoid coupling effects caused by braid currents. Standard configuration: N-male, N-female,  length ca. 0.2-0.3 m. Required for isolation measurements. 
KA 8127 NEMA 
BNC female to NEMA male.  Fits for all LISN types with NEMA socket. 
 

Request a Quote / Contact Us!
Schwarzbeck Mess-Elektronik

Schwarzbeck products