Reliant EMC

sPECIAL - PV- / Tempest- LISN

PV- / Tempest- LISN from Schwarzbeck
ECSS LISN 1
ECSS LISN 2
ECSS LISN 3
NPLC 8500 for ITU-T G.9901
NDTV 8160
(discontinued)
Pilot ISN - Impedance Stabalisation Network
PVDC 8300 - DC-AMN (LISN)
PVDC 8301 - DC-AMN (LISN)
TEMP 8400 - Tempest LISN
TEMP 8401
 
ECSS LISN 1

Schwarzbeck ECSS LISN 1

The ECSS LISN 1 was developed following the „European Cooperation for Space Standardisation“. The ECSS LISN 1 is used for DC mains lines. The impedance characteristic of each path is basically realized by an inductor in parallel with the 50 Ohm resistor: 1.5 μH || 50 Ω.

 

Frequency Range:
10 Hz - 150 MHz

 

Max. cont. current:
10 A

 

Max. current (limited time):
15 A

 

Max. voltage (DC):
200 V

 

Impedance:
(1.5 µH ) || 50 Ω

 

DC-Recistance mains-EuT:
100 mΩ

 

EuT connectors:
screw terminals M7x0.75
unscrewable with 4 mm jacks

 

Dimensions (WxHxD):
160 x 165 x 210 mm

 

Weight
2.7 kg

 

Standard:
ECSS-E-ST-20-07 Rev1
 
pdficon small Schwarzbeck ECSS LISN 1 Double path AMN Data Sheet
 

 

ECSS LISN 2

Schwarzbeck ECSS LISN 2

The ECSS LISN 2 was developed following the „European Cooperation for Space Standardisation“. The ECSS LISN 2 is used for DC mains lines. The impedance characteristic of each path is basically realized by an inductor in parallel with the 50 Ohm resistor: 2 μH || 50 Ω.
 

 

Frequency Range:
10 Hz - 150 MHz

 

Max. cont. current:
10 A

 

Max. current (limited time):
15 A

 

Max. voltage (DC):
200 V

 

Impedance:
(2 µH ) || 50 Ω

 

DC-Resistance mains-EuT:
100 mΩ

 

EuT connectors:
screw terminals M7x0.75
unscrewable with 4 mm jacks

 

Dimensions (WxHxD):
160 x 165 x 210 mm

 

Weight
2.7 kg

 

Standard:
ECSS-E-ST-20-07 Rev1
 
pdficon small Schwarzbeck ECSS LISN 2 Double path AMN Data Sheet
 

 

ECSS LISN 3

Schwarzbeck ECSS LISN 3

The ECSS LISN 3 was developed following the „European Cooperation for Space Standardisation“. The ECSS LISN 3 is used for DC mains lines. The impedance characteristic of each path is basically realized by an inductor in parallel with the 50 Ohm resistor: 0.7 μH || 50 Ω.
 

 

Frequency Range:
10 Hz - 150 MHz

 

Max. cont. current:
10 A

 

Max. current (limited time):
15 A

 

Max. voltage (DC):
200 V

 

Impedance:
(0.7 µH ) || 50 Ω

 

DC-Resistance mains-EuT:
50 mΩ

 

EuT connectors:
screw terminals M7x0.75
unscrewable with 4 mm jacks

 

Dimensions (WxHxD):
160 x 165 x 210 mm

 

Weight
2.4 kg

 

Standard:
ECSS-E-ST-20-07 Rev1
 
pdficon small Schwarzbeck ECSS LISN 3 Double path AMN Data Sheet
 

 

NPLC 8500
Schwarzbeck LISN NPLC 8500
· The LISN NPLC 8500 has been designed especially for PLC measurements according to ITU-T G.9901.
· Frequency range: 3 kHz - 148.5 kHz
· Max. terminal voltage: 250 V AC / 50 Hz
· Max. current: 16 Arms
· AMN Impedance: 1 Ohm
 
Schwarzbeck NPLC 8500 Line Impedance Stabilization Network Data Sheet Data Sheet NPLC 8500
 

 

NDTV 8160
· Universal Delta-, T-, V-LISN
 
Schwarzbeck NDTV 8160 Data Sheet Data Sheet NDTV 8160
Schwarzbeck NDTV 8160 Manual Manual NDTV 8160
 

 

Pilot ISN - Impedance Stabilisation Network
Schwarzbeck Pilot ISN AE
Schwarzbeck Pilot ISN EUT
Pilot ISN is an impedance stabilization network which can be used to measure disturbance voltages of PLC (power line communication). Its design is based on IEC 61851-21-1 Electric vehicle conductive charging system.
 
The ISN provides decoupling from the equipment under test (EuT) and the communication device or load (AE). The Pilot ISN has an impedance of 150 Ω according to the standard as long as a PLC connection with an impedance of 100 Ω is established. The integrated attenuator improves the impedance matching and has to be switched on.
 
Frequency Range:
150 kHz - 30 MHz
Connector:
Safety laboratory jacks, 4 mm
Max. line current/path:
1.4 A DC
Max. voltage
Power line - ground:
200 V DC
140 V AC
Common mode impedance
EuT-side:
150 Ω ±20 Ω
Dimensions W x H x D:
125 mm x 55 mm x 105 mm
Weight:
480 g
According to standard:
IEC 61851-21-1 
Electric vehicle conductive charging system
 
Schwarzbeck DC AMN (LISN) PVDC 8300 Data Sheet Schwarzbeck Pilot ISN Impedance Stabilisation Network Data Sheet
 
 
PVDC 8300
Schwarzbeck LISN PVDC 8300
· PV LISN
· 1500 V
· 50 A
· common mode impedance 150 Ohm
· Z differential mode = 100 Ohm
· air coils 280 microhenry
· PVDC 8300 Opt. Fans
· Fans for a maximum continuous current of 100 A
 
Schwarzbeck DC AMN (LISN) PVDC 8300 Data Sheet Data Sheet PVDC 8300
 

 

PVDC 8301
Schwarzbeck LISN PVDC 8301
· PV-LISN for the DC side of grid connected power converters GCPC.
· 1500 V
· 200 A
· common mode impedance = 150 Ohm
· differential mode impedance = 100 Ohm
· air coils 280 microhenry
 
Schwarzbeck DC AMN (LISN) PVDC 8300 Data Sheet Data Sheet PVDC 8301
 

 

TEMP 8400
Schwarzbeck LISN TEMP 8400
· Tempest LISN
· 9 kHz to 1 GHz
· 2 path model 16 A
· N-connectors for DuT power supply and N-connectors for the 2 measurement ports.
· The unit allows to listen to even the smallest signals on power lines.
 
Schwarzbeck Tempest AMN (LISN) TEMP 8400 Data Sheet Data Sheet TEMP 8400
 
TEMP 8401
Schwarzbeck LISN TEMP 8401
· Adapter N-male to wing terminals for TEMP 8400
 
Request a Quote / Contact Us!
Schwarzbeck Mess-Elektronik

Schwarzbeck products