Reliant EMC

Clamps: Abosorbing, Injection and CCC

Schwarzbeck Clamps
• CCC 9224 Capacitive Coupling Clamp
• CCP 9225 Capacitive Coupling Plate
• CMAD 1614 Common Mode Absorption Clamp/Device
• CAL CMAD 1614 - Calibration Fixture for CMAD 1614
• EM 101 + FTC 101 
• EM 101 Cal Kit
• EM 101 Current Injection Clamp
FT 33X15 Surface Current Blocking Filter
FTC 101 Surface Current Blocking Filter Clamp
FTC40X15E Absorbing Clamp
MDS 21 B EMI Absorbing Clamp
SW 9605 Current Transformer Clamp
SW 9606 Current Injection Clamp

 

CCC 9224 Capacitive Coupling Clamp
Schwarzbeck CCP 9224 Capacitive coupling clamp for transients acc. to ISO 7637-3 or DC-10614
 · Capacitive coupling clamp for transients according to to ISO 7637-3 or DC-10614 B.5.
 
pdficon small Data Sheet CCC 9224

 

CCP 9225 Capacitive Coupling Plate
Schwarzbeck CCP 9225 Capacitive Coupling Plate 
· Capacitive coupling plate
· The main application is to conduct CV-tests (capacitive voltage measurements).
· The capacitive coupling plate CCP 9225 complies to the automotive manufacturer standard MBN 10284-2 2011-04, Annex B.

 

pdficon small Data Sheet CCP 9225

 

 

CMAD 1614 - Common Mode Absorption Clamp/Device
Schwarzbeck CMAD 1614 Common Mode Absorption Device

 

Schwarzbeck CMAD 1614 Common Mode Absorption Device open

The CMAD 1614 - Common Mode Absorption Device consists of many precision cut ferrite half-toroids, which are embedded in a grey plastic housing. The unique floating toroid bearing ensures a perfect fit of the ferrite surfaces. Two quick-locks at the long side allow opening and closing of the clamp within seconds.
Cable bundles or coaxial cables with a maximum diameter of 26 mm are accepted by the clamp without disassembling connectors or interrupting any circuitry.
The combination of short length and large cable hole diameter offer a broad variety of applications for the CMAD 1614.
 
Each common mode absorption device comes with an individually measured calibration certificate.
 
The CMAD 1614 can be used for both, coaxial cables and unshielded cable bundles, in order to suppress unwanted common mode currents (also called braid currents). Since these unwanted common mode currents are very often a reason for poor repeatability of measurements, the new CISPR 16-1-4 standard recommends the use of absorbing clamps.

 

Frequency Range:
30 MHz - 200 MHz
Specified in:
CISPR 16-1-4
Usable Frequency Range:
10 MHz - 1 GHz
S11 (30 MHz):
0.6 - 0.75
S11 (200 MHz):
0.4 - 0.55
S21:
< 0.25
Max. Cable Diameter:
26 mm
Housing Material:
PVC
Housing Dimensions:
66 x 70 x 414 mm
Weight:
3.2 kg
 
pdficon small Schwarzbeck CMAD 1614 - Common Mode Absorption Clamp/Device Data Sheet

 

CAL CMAD 1614 - Calibration Fixture for CMAD 1614
CAL CMAD 1614 - Calibration Fixture for CMAD 1614
The CAL CMAD 1614 calibration fixture is used to calibrate / verify the performance of the common mode absorption device CMAD 1614. The fixture consists of an aluminium base plate with two sideplates, adjustable in height and position and each of them equipped with N-connector and inner conductor fixture. A variety of inner conductors with 4 mm diameter is part of the delivery. The calibration fixture was designed for measurements acc. to CISPR 16-1-4 sections 9.5 and 9.6.

 

Frequency Range:
30 MHz - 200 MHz
Specified in:
CISPR 16-1-4
Useable Frequency Range:
10 MHz - 1 GHz
Material:
Aluminium
Dimensions:
113 x 150 x 788 mm
Weight:
2.2 kg

 

pdficon small Schwarzbeck CAL CMAD 1614 - Calibration Fixture for CMAD 1614 Data Sheet

 

EM 101 + FTC 101 
· System injection clamp EM 101 with braid current blocking clamp FTC 101
· FT14X15 Surface current blocking filter 100 - 1000 MHz

 

pdficon small Schwarzbeck FG14x15 Injection and Braid Current Blocking Data Sheet

 

EM 101 Cal Kit  
· Calibration kit for EM 101
· consisting of 2ea CR 100
· 1 safety lab cable 10 cm
· 1ea cable 80 cm
· both sides banana

 

EM 101 Current Injection Clamp 
· Current Injection Clamp
· 0.15 - 1000 MHz
· 100 W
· 4kV max.
· max. cable diameter 22mm
 
pdficon small Schwarzbeck EM 101 Current Injection Clamp Data Sheet
pdficon small Schwarzbeck EM 101 Current Injection Clamp Manual
pdficon small Schwarzbeck EM 101 Current Injection Clamp Data

 

· FT34X15 Surface current blocking filter 1 - 1000 MHz

 

· FT 32 Surface current blocking filter 0.01 - 1000 MHz
pdficon small Schwarzbeck FT 32 Surface Current Blocking Filter Data Sheet
· FTC40X15C Absorbing Clamp 10 - 1000 MHz

 

FT33X15  
· Surface current blocking filter
· 10 - 1000 MHz
pdficon small Schwarzbeck FG 33X15 Surface Current Blocking Filter Data Sheet

 

FTC 101  
· Surface current blocking filter clamp
· (in combination w. EM 101)
 
pdficon small Schwarzbeck FTC 101 Surface Current Blocking Filter Clamp Data Sheet

 

FTC40X15E  
· Absorbing Clamp
· 1 - 1000 MHz
· CISPR 22

 

pdficon small Data Sheet FTC40X15E

 

MDS 21 B EMI Absorbing Clamp
Schwarzbeck MDS 21 B Absorbing Clamps

 

Schwarzbeck MDS 21 B Absorbing Clamps 2

· EMI Absorbing Clamp
· 30 - 1000 MHz
· according to CISPR 16 for interference power with silicon coated rolls
Also for shielding measurements on coax. cables
pdficon small Schwarzbeck MDS 21 B EMI Absorbing Clamp Data Sheet

 

 

SW 9605 Current Transformer Clamp  
Schwarzbeck SW 9605 Current Transformer
 · Current Transformer Clamp
 · CISPR 22
 · 9 kHz - 80 MHz
 · Transfer Impedance: 1 Ohm for wires up to 23 mm
 
Data Sheet SW 9605

 

 

 
SW 9606 Current injection clamp  
 · Current injection clamp for RF current injection into harnesses
up to 23 mm diameter
 · transducer 18 dB
 
Data Sheet SW 9606

 

 

Request a Quote / Contact Us!
Schwarzbeck Mess-Elektronik

Schwarzbeck Products