Reliant EMC

IT-XX Isolation Transformers

Schlöder IT-06 / IT-16 / IT-20 Isolation-Transformers with double shield winding

Schlöder IT-06 IT-16 IT-20 Isolation-Transformers

Specifications
IT-06
IT-16
IT-20
Primary
230 V
230V
230V
Secondary
230 V / 6 A
230 V / 16 A
230 V / 20 A
Power
1380 VA
3680 VA
4600 VA
Asymmetric damping
(15 Hz - 150 kHz)
60 dB
60 dB
60 dB
Isolation
> 1 kV (50/60 Hz)
> 1 kV (50/60 Hz)
> 1 kV (50/60 Hz)
 
Dimensions (L x W x H)
330 mm x 230 mm x 111 mm
400 mm x 310 mm x 181 mm
400 mm x 310 mm x 181 mm
Weight
~18 kg
~34 kg
~45 kg
 
  • IT-16, IT-20 as a three-phase system
    A three-phase network consisting of three 120-degree phase-shifted conductors can be galvanically isolated by means of three individual insulation transformers of the same type with high common-mode rejection. Prerequisite is a symmetrical load, since a three-phase system of three individual transformers should not be unbalanced i. the zero conductor should not carry any current!
    The three IT-16 (max. 16 A) or IT-20 (max 20A) transformers are operated in star connection both on the input side and on the output side. The neutral conductor (blue) should not be routed to the test object for safety reasons.

    Model
    Decription
    IT-06
    Isolation transformer 1380VA acc.EN 61558 with shield winding between Primary and
    Secondary; Primary: 230 V / 50-60 Hz; Secondary: 230 V / 6 A; Aluminum casing
    IT-16
    Isolation transformer 3680VA acc.EN 61558 with shield winding between Primary and
    Secondary; Primary: 230 V / 50-60 Hz; Secondary: 230 V / 16 A; Aluminum casing
    IT-20
    Isolation transformer 4600VA acc.EN 61558 with shield winding between Primary and
    Secondary; Primary: 230 V / 50-60 Hz; Secondary: 230 V / 20 A; Aluminum casing
  •  

Aaronia_AG_BicoLOG_5070_Biconical_Antenna_Data_Sheet Schlöder IT-06 / IT-16 / IT-20 Isolation-Transformers with double shield winding Data Sheet

 

Accessories
Coupling Networks - 3 Phase
SFT 415 Capacitive Coupling Clamp
SFT 415 - CS: Calibration Set for CCC
SFT 450-1 (50 Ohm) and SFT 450-2 (1000 Ohm) Attenuators
SFT 470 Probe Set - Magnetic Field
SESD 30 S 100 ESD-Soft 6 ESD Remote Control Software
 
Request a Quote / Contact Us!

 

Schlöder
 

SchlÖder Product Line

Schlöder Company Information
 
Schlöder ESD Simulators and ESD Test System
Schlöder EMC Generators / Measurement Systems

Schlöder CDN - Coupling Decoupling Network


Schlöder Coupling Networks for Burst & Surge
CN 1240-32 and CN 1240-125 Coupling Switchable Networks
Schlöder Current Monitoring Probes
Schlöder Accessories
Schlöder Helmholtz Coils

Schlöder Signal Generator SG 0282

Schlöder Isolation-Transformers with double shield winding

Schlöder Power Frequency Magnetic Field Immunity Tests
Schlöder MGA_BC-500 Field Coil acc. to EN 55103-2
Schlöder MGA 1030 Magnetic Field System Data Sheet
Schlöder MGA 1030 Magnetic Field Generator and Analyzer Additional Equipment Data Sheet
 
Schlöder Products by Standards

Reliant EMC Product Lines