PA 503 Safety Test Cabinet
PA 505 Safety Test Cabinet
PA 525 Safety Test Cabinet
PU 12 A-B DUT Switchover
Safety Test Cabinets

 

PA 503 Safety Test Cabinet
PA 503 Safety test cabinet
 
Summary:
• Safety test cabinet
• Test voltage: 6 kV / 12 kV
• Dimensions W*H*D: 470 * 280 * 490 mm³
 
The safety test cabinet PA 503 is designed for high-voltage testing of components and PCB's etc. The transparent cabinet prevents accidental contact with live parts of the test object, yet allows observation of the test object during testing.
 

 

 
PA 505 Safety Test Cabinet
PA 505 Safety test cabinet
 
Summary:
• Safety test cabinet
• Test voltage: 10 kV
• Dimensions W*H*D: 440*250*500 mm³
 
The safety test cabinet PA 505/ PA 525 is designed for high-voltage testing of components and PCB's etc. The transparent cabinet prevents accidental contact with live parts of the test object, yet allows observation of the test object during testing.
 
 

 

PA 525 Safety Test Cabinet

PA 525 Safety test cabinet

Summary:
• Safety test cabinet
• Test voltage: 12 kV
• Dimensions W*H*D: 440*250*500 mm³
 
The safety test cabinet PA 505/ PA 525 is designed for high-voltage testing of components and PCB's etc. The transparent cabinet prevents accidental contact with live parts of the test object, yet allows observation of the test object during testing.
 

 

PU 12 A-B DUT Switchover
HILO-TEST PU 12 A-B DUT Switchover
 
Summary:
• DUT switchover
• High voltage test of devices
 
For high-voltage testing of components, a DUT switchover is available for different pulse generators.
 
By using the PU 12 A-B DUT Switchover the testing time be significantly reduced and increased the throughput significantly. The specimens are contacted via test adapter that new line during the test can be fitted and replaced quickly. Direct testing of 8/10/12 or 15 individual specimens or the "Differential / common mode" testing the a / b wires of IT equipment can be realized will. The control of the PU 12 A-B DUT Switchover done from the test generator.
The specimens are covered during the test by a safety test.
Of the Following the test generator is carried coaxially on the back of the units. To this Thus achieved a high degree of personal safety for the operating personnel.
Block diagram, by way of example:

To monitor the test quantities can pulse voltage divider and / or Current viewing resistors are integrated into the PU 12 A-B DUT Switchover.
 
 

 

Safety Test Cabinets
Data Sheet
 
Description
 
PA 503
Safety test cabinet
Test space ca. W*H*D: 400 / 140 / 250 
PA 501/502
Safety test cabinet
Test space ca. W*H*D: 440 / 180 / 300           
PA 505/525
Safety test cabinet
Test space ca. W*H*D: 400 / 250 / 400 
PA 504
Safety test cabinet
Test space ca. W*H*D: 490 / 300 / 300 
 
 
Request a Quote / Contact Us!

 

 

Hilo-Test product Line

HILO-TEST Company Information

HILO-TEST Product Categories:
AC DC Test Equipment
Accessories
Automotive EMC Test Systems
Burst (EFTG) Simulators / Burst Calibration Kit
Coupling Network (CDN)
ESD Generators
High Voltage Dividers
Impulse Current Generators
Impulse Voltage Generators
Miscellaneous Products
Multifunction Generators
Oscillatory wave generator systems
Power Fail Generators
Ring-wave Generators
Shunts
Software
Surge (Hybrid) Generators
Telecom Generators

HILO-TEST PRODUCTS BY STANDARDS CATAGORIES
EMC Test Equipment
CCITT Test Equipment, Series K
 
Component Test Generators
  • • High Voltage Pulse Generators
    • • PG 10-200/PG 12-360 Accessories
    • High Current Pulse Generator
High Voltage Test and Measurement Equipment
  • • AC and DC
    • High Voltage Measurement Equipment
    • Calibration Equipment
Other Products

Reliant EMC Product Lines