The Hilo-Test CCITT Test Equipment, Series K is designed for the testing of gas discharge tubes for the protection of telecommunication installations. 
Data Sheet
 
Description
 
Measurement of dc- and impulse spark-over voltage of gas discharge tubes:
IPG 506
Front-chopped-wave Generator
Measurement of spark-over voltage of gas discharge tubes, according to CCITT.K12 / ITU-T, K44 Impulse voltage 5 kV: dU/dt = 100 V/µs - 5000 V/µs
DC-voltage      637 V: dU/dt = 100 V/s
 
 
Surge current testing of over-voltage protectors:
PG 6-200
Surge current generator: 5.0 kA, 8/20 µs
PG 6-400
Surge current generator: 10.0 kA, 8/20 µs
EMC 2015
Pulse Generator System
Mainframe with various pulse forming plug-in`s.
Pulse currents: 
8 / 20 µs,
 
 
20 kA,
1500 J
10 / 50 µs,
5 kA,
1500 J
10 / 350 µs,
600 A,
1500 J
10 / 700 µs,
300 A,
1500 J
10 / 1000 µs,
200 A,
1500 J
PG 6-2402
Surge current generator:  2 * 25 kA, 8/20 µs
PG 6-432
Impulse Life Test Generator
Designed for testing two-gap over-voltage protectors, specified in CCITT 12 TR 1, K12
Surge current : 
10 / 700 µs,
 
 
2 * 100 A,
360 J
10 / 1000 µs,
2 * 100 A,
360 J
HVTG 2/10
High-Voltage Test Unit
Designed for cw-testing of over-voltage protectors, specified in CCITT, 12 TR 1, K17
Open circuit output voltage : 2 kV-rms
Short circuit output current: 10 A-rms
> Test interval: CW or 0-999 cycles
High-voltage Pulse Generators designed for
testing telecom equipment:
PG 2-750
Surge current generator:  
according to FCC, Part 68, ANSI/TIA 968-A-2002
current wave : 
10 / 160 µs,
 
 
1600 V,
4 * 100 A
10 / 560 µs,
800 V,
2 * 100 A
Option 2:       
10 / 1000 µs,
 
 
1000 V,
 
2 * 100 A,
 
GR-1089-CORE
PG 6-500
Surge current generator:  
2/10 µs wave, according to GR-1089-CORE
first level lightning surge:
 
± 2500 V,
 
 
500 A,  2/10 µs,
 
 
4 wires
second level lightning surge:
 
± 5000 V,
500 A,  2/10 µs,
4 wires
intra building lightning surge:
 
±   800 V,
 
 
100 A,  2/10 µs,
 
 
4 wires
intra building lightning surge:
 
± 1500 V,
 
 
100 A,  2/10 µs,
 
 
4 wires
IPG 620
High-voltage Pulse Generator
Lightning surge: 1.2/50µs, 6 kV, 20 J, CCITT K22; ITU-T- K44 
IPG 1050
High-voltage Pulse Generator
Lightning surge: 1.2/50µs, 10 kV, 50J, CCITT K22; ITU-T- K44
PG 5-200-1
High-voltage Pulse Generator
Switching surge: 10/700 µs, 5 kV, 200 J, specified in 
CCITT K17-K22; ITU-T- K44
PG 5-200-2
High-voltage Pulse Generator
Lightning surge: 1.2/50 µs, 5 kV, 10 J, specified in
CCITT K17-K22; ITU-T- K44
Switching surge: 10/700 µs, 5 kV, 200 J, specified in
CCITT K17-K22; ITU-T- K44
PG 6-364
High-voltage Pulse Generator
Lightning surge: 1.2/50 µs, 6 kV, 20 J, specified in
CCITT K17-K22; ITU-T- K44
Switching surge 10/700 µs, 6 kV, 360 J, specified in
CCITT K17-K22; ITU-T- K44
One additional wave form available: 100/700 µs, 0.5/700 µs oder 1/1000 µs.
PG 10-1000
High-voltage Pulse Generator
Lightning surge: 1.2/50 µs, 10 kV, 50 J, specified in 
CCITT K17-K22; ITU-T- K44
Switching surge 10/700 µs, 10kV, 1000 J, specified in 
CCITT K17-K22; ITU-T- K44
PG 12-1440
High-voltage Pulse Generator
Lightning surge: 1.2/50 µs, 12 kV, 72 J, specified in CCITT 12 TR 1, K17, K20
Switching surge 10/700 µs, 12kV, 1440 J, specified in CCITT 12 TR 1, K17, K20
PG 14-1960
High-voltage Pulse Generator
Switching surge 10/700 µs, 14 kV, 2000 J, specified in 
CCITT K17-K22; ITU-T- K44
PG 20-4000
High-voltage Pulse Generator
Switching surge 10/700 µs, 20 kV, 4000 J, specified in 
CCITT K17-K22; ITU-T- K44
PG 4-640
High-voltage Pulse Generator
Switching surge 10/700 µs, 4 kV, 640 J, specified in ITU-T Spec. K44
PIG 1500
Power Induction Generator
designed for testing telecommunication ports, specified in CCITT, 12 TR 1, K20
Open circuit output voltage : 20 - 1500 V-rms, test time: 0.1 - 2.5 sec
Coupling impedance: + 0,5µF, + 1.0µF, //100 Ohm
Accessories
KN 100-4
Coupling Network
4 decoupling resistors 100 Ohm, specified in CCITT 12 TR1, K17, K20
CDN 5-64
Coupling Network
64 outputs, max. test voltage 5 kV, 10/700µs
designed for coupling to ISDN-Ports, output selectable: one of 64
CDN 5-80
Coupling Network
80 outputs, max. test voltage 5 kV, 10/700µs
designed for coupling to ISDN-Ports, outputs selectable: 20 of 80
 
 
Request a Quote / Contact Us!

 

 

Hilo-Test product Line

HILO-TEST Company Information

HILO-TEST Product Categories:
AC DC Test Equipment
Accessories
Automotive EMC Test Systems
Burst (EFTG) Simulators / Burst Calibration Kit
Coupling Network (CDN)
ESD Generators
High Voltage Dividers
Impulse Current Generators
Impulse Voltage Generators
Miscellaneous Products
Multifunction Generators
Oscillatory wave generator systems
Power Fail Generators
Ring-wave Generators
Shunts
Software
Surge (Hybrid) Generators
Telecom Generators

HILO-TEST PRODUCTS BY STANDARDS CATAGORIES
EMC Test Equipment
CCITT Test Equipment, Series K
 
Component Test Generators
  • • High Voltage Pulse Generators
    • • PG 10-200/PG 12-360 Accessories
    • High Current Pulse Generator
High Voltage Test and Measurement Equipment
  • • AC and DC
    • High Voltage Measurement Equipment
    • Calibration Equipment
Other Products

Reliant EMC Product Lines