CHC – Compact Hybrid Chamber

Frankonia CHC – Compact Hybrid Chamber, 3m test distance

CHC – Compact Hybrid Chamber, 3m test distance
Frankonia CHC – Compact Hybrid Chamber, 3m test distance
 
The CHC is the optimal solution for immunity tests according to the standard IEC/EN 61000-4-3 for a measuring distance of 3m and offers in this size the best characteristics for pre-acceptance emission measurements.
The installation of ferrite and partially of hybrid absorbers allows measurements in the frequency range from 30 MHz to at least 18 GHz.
The CHC can be delivered optionally as a semi-anechoic chamber (with ground plane) or as a fully anechoic chamber (floor absorbers on the whole floor surface).
For immunity tests, floor absorbers are required in each case between transmitting antenna and EUT and are therefore included in the standard delivery volume.
 
Performance:
SHIELDING EFFECTIVENESS (SE)
Acc. to EN 50147-1 from 10kHz to 18GHz the following values are guaranteed: see table paragraph 1
EMISSION - pre-compliance
According to CISPR 16-1-4
Test distance: 3,0m
Frequency range: 30MHz- 200MHz (pre-compliance)
Frequency range: 200MHz- 1GHz (compliance)
Quiet Zone: Ø1,2m (2m H)
 
IMMUNITY - pre-compliance
According to IEC/EN 61000-4-3/ ISO 11452-2
Test distance: 3,0m
Frequency range: 80MHz- 18GHz
Uniform area: 0,5m x 0,5m
Guaranteed FU: -0/+6dB for 12 of 16 test points (75%)
 
Outside shielding dimensions (LxWxH): 7,355 x 3,755 x 3,300m
Shielding and structure
Quantity
Unit
Shielding modules PAN type
1
Set
Ceiling/ wall reinforcement
1
Set
Rubber membrane under the chamber for humidity protection
1
Set
Absorber ferrite tiles F006
Floor lined with F006 (7,2m²) for EMS (FU)
1
Set
Walls and ceiling lined with F006
1
Set
Rail substructure for ferrite tile plates
1
Set
Absorber Frankosorb® pyramids – fire class B2 DIN 4102/ DIN EN 13501-1 (2010-01)
Floor with H600 B2 (7,2m²) for EMS (FU)
1
Set
Small wall behind the turntable lined with H450 B2
1
Set
Side walls partially lined with H450 B2 (approx. half of the chamber)
1
Set
Ceiling partially lined with H450 B2 (approx. half of the chamber)
1
Set
 
Personal door type 2011 - External leaf painted RAL 9002 (light grey)
SLD 10/20/M Personal door with clear opening 1013 x 2043mm with manual latching, prepared for receiving absorbers
1
Pc
Door stopper
1
Pc
Manual wooden ramp, load capacity 200kg

1

Pc

Penetration panels, feed throughs & connectors
Penetration panel (PP) 400 x 400mm, including C-frame
1
Pc
N connector
4
Pcs
N+BNC adaptor
4
Pcs
FSMA connector
4
Pcs
Floor connection panels & connectors
Connection panel (CP) 600 x 600mm - automatic with jacks
2
Pcs
N connector
4
Pcs
BNC connector
4
Pcs
FSMA connector
4
Pcs
 
 
Power filter and grounding point
Insertion loss high performance filters: 100dB from 14kHz to 40GHz
Power filter 2x6A - 250V AC - 50/60Hz for the chamber
1
Pc
Power filter 2x32A - 250V AC - 50/60Hz for the EUT
1
Pc
Electrical installation
Electrical installation
1
Set
Lighting Halogen 230W
4
Pcs
Shielded access box to the electrical distribution box with access from inside
1
Pc
Electrical ducts in raised floor
1
Set
Socket: 1phase 60Hz 32A (US type)
1
Pc
Socket: Duplex single phase 16A (US type)
3
Pcs
Emergency lighting low noise with 3 lights and outside UPS with filter
1
Set
Honeycombs
Honeycombs 400 x 400mm - 18GHz
2
Pcs
Floor
Height: 150mm
Raised floor modular standard up to 500 kg/m² with hot galvanized ground plane 2,0mm
1
Set
 
Standard Equipment
· 1 access door, 1.013 x 2.043 mm
· 1 honeycomb insert for ventilation
· 1 mains filter 250 VAC, 2 x 16 A
· 1 penetration panel
· Feed-throughs: 4 x “N”, 4 x “BNC” and 1 x for fibre optics
· Electric installation
· Illumination
· Raised floor
· Absorber lining
 
Options
· 3 phase mains filter
· Signal and / or data line filter
· Fan · Antenna tripod
· Video and / or audio system
· Verification of the chamber
· Measuring equipment
· Other extras

 

For more detail, please download the following pdf file

 
Request a Quote / Contact Us!

 