Reliant EMC

FRANKONIA GROUP Product List

 

Frankonia Product List August 1 2016

 

 
Frankonia
Model #
Product Description
 
Frankonia EMV - RF-Power Amplifiers
RF-Power Amplifiers: 10 kHz - 300 MHz Frequency Range
 
FLL-25
RF-Power-Amplifier
Frequency-range: 100kHz to 250MHz
Output Power: 25 Watt
FLL-25A
RF-Power Amplifier
Frequency-range: 10kHz to 230MHz
Output Power: 25 Watt
FLL-75
RF-Power Amplifier
Frequency-range: 100kHz to 300MHz
Output Power: 75 Watt
FLL-75A
RF-Power Amplifier
Frequency-range: 150kHz to 230MHz
Output Power: 75 Watt
FLL-100A
RF-Power Amplifier
Frequency-range: 10kHz to 250MHz
Output-Power: 100W
VLL-140
RF-Power Amplifier
Frequency-range: 10kHz to 250MHz
Output Power: 140 Watt
VLL-300
RF-Power Amplifier
Frequency-range: 10kHz to 250MHz
Output Power: 300 Watt
VLL-500L
RF-Power Amplifier
Frequency-range: 100kHz to 200MHz
Output Power: 500 Watt
VLL-600
RF-Power Amplifier
Frequency-range: 10kHz to 250MHz
Output Power: 600 Watt
VLL-1000L
RF-Power Amplifier
Frequency-range: 100kHz to 200MHz
Output Power: 1000 Watt
VLL-1300
RF-Power Amplifier
Frequency-range: 10kHz to 250MHz
Output Power: 1300 Watt
VLL-2000L
RF-Power Amplifier
Frequency-range: 100kHz to 200MHz
Output Power: 2000 Watt
VLL-2500
RF-Power Amplifier
Frequency-range: 10kHz to 250MHz
Output Power: 2500 Watt
VLL-3500L
RF-Power Amplifier
Frequency-range: 100kHz to 200MHz
Output Power: 3500 Watt
VLL-5000
RF-Power Amplifier
Frequency-range: 10kHz to 250MHz
Output Power: 5000 Watt
VLL-7000L
RF-Power Amplifier
Frequency-range: 100kHz to 200MHz
Output Power: 7000 Watt
VLL-10000
RF-Power Amplifier
Frequency-range: 10kHz to 250MHz
Output Power: 10000 Watt
VLL-12000L
RF-Power Amplifier
Frequency-range: 100kHz to 200MHz
Output Power: 12000 Watt
RF-Power Amplifiers: 10 kHz - 400 MHz Frequency Range
VLC-60
RF-Power Amplifier
Frequency-range: 10kHz to 400MHz
Output Power: 60 Watt
FLC-75
RF-Power Amplifier
Frequency range:  100kHz to 400MHz
Output Power: 75 Watt
VLC-110
RF-Power Amplifier
Frequency-range: 10kHz to 400MHz
Output Power: 110 Watt
FLC-180
RF-Power Amplifier
Frequency range:  1MHz to 400MHz
Output Power: 180 Watt
VLC-220
RF-Power Amplifier
Frequency-range: 10kHz to 400MHz
Output Power: 220 Watt
VLC-400
RF-Power Amplifier
Frequency-range: 10kHz to 400MHz
Output Power: 400 Watt
VLC-600
RF-Power Amplifier
Frequency-range: 10kHz to 400MHz
Output Power: 600 Watt
VLC-1200
RF-Power Amplifier
Frequency-range: 10kHz to 400MHz
Output Power: 1200 Watt
VLC-2000
RF-Power Amplifier
Frequency-range: 10kHz to 400MHz
Output Power: 2000 Watt
RF-Power Amplifiers: 10 kHz - 1000 MHz Frequency Range
VLLH-25
RF-Power Amplifier
Frequency-range: 10kHz to 1000MHz
Output Power: 25 Watt
VLLH-70
RF-Power Amplifier
Frequency-range: 10kHz to 1000MHz
Output Power: 70 Watt
VLLH-150
RF-Power Amplifier
Frequency-range: 10kHz to 1000MHz
Output Power: 150 Watt
VLLH-260
RF-Power Amplifier
Frequency-range: 10kHz to 1000MHz
Output Power: 260 Watt
VLLH-800
RF-Power Amplifier
Frequency-range: 10kHz to 1000MHz
Output Power: 800 Watt
RF-Power Amplifiers: 1 MHz - 1000 MHz
FLH-4A
RF-Power Amplifier
Frequency-range: 1MHz to 1000MHz
Output Power: 4 Watt
FLH-50A
RF-Power Amplifier
Frequency-range: 1MHz to 1000MHz
Output Power: 50 Watt
FLH-100A
RF-Power Amplifier
Frequency-range: 1MHz - 1000 MHz
Output Power: 100 Watts
FLH-100C
RF-Power Amplifier
Frequency-range: 20MHz - 500MHz
Power-output: 100W
FLH-200C
RF-Power Amplifier
Type: FLH-200C
Frequency-range: 20MHz - 500MHz
Power-output: 200W
RF-Power Amplifiers: 20 MHz - 1 GHz
FLH-20B
RF-Power Amplifier
Frequency-range: 20MHz - 1GHz
Output Power: 20 Watts
FLH-70B
RF-Power Amplifier
Frequency-range: 20MHz - 1GHz
Output Power: 70 Watts
VLH-90B
RF-Power Amplifier
Frequency-range: 20MHz to 1GHz
Output Power: 90 Watt
VLH-160B
RF-Power Amplifier
Frequency-range: 20MHz to 1GHz
Output Power: 160 Watt
FLH-200B
RF-Power Amplifier
Frequency-range: 20MHz - 1GHz
Power-output: 200W
VLH-320B
RF-Power Amplifier
Frequency-range: 20MHz to 1GHz
Output Power: 320 Watt
VLH-600B
RF-Power Amplifier
Frequency-range: 20MHz to 1GHz
Output Power: 600 Watt
RF-Power Amplifiers: 80 MHz - 1 GHz
VLH-100B1
RF-Power Amplifier
Frequency range: 80MHz to 1000MHz
Output Power: 100 Watt
FLH-200B1
RF-Power Amplifier
Frequency-range: 80MHz - 1000MHz
Power-output: 200W
VLH-400B1
RF-Power Amplifier
Frequency-range: 80MHz to 1000MHz
Output Power: 400 Watt
FLH-500B1
RF-Power Amplifier
Frequency-range: 80MHz - 1000MHz
Output Power: 500W
VLH-700B1
RF-Power Amplifier
Frequency-range: 80MHz to 1000MHz
Output Power: 700 Watt
VLH-1200B1
RF-Power Amplifier
Frequency-range: 80MHz to 1000MHz
Output Power: 1200 Watt
VLH-1400B1
RF-Power Amplifier
Frequency-range: 80MHz to 1000MHz
Output Power: 1400 Watt
VLH-1700B1
RF-Power Amplifier
Frequency-range: 80MHz to 1000MHz
Output Power: 1700 Watt
VLH-2000B1
RF-Power Amplifier
Frequency-range: 80MHz to 1000MHz
Output Power: 2000 Watt
VLH-3500B1
RF-Power Amplifier
Frequency-range: 80MHz to 1000MHz
Output Power: 3000 Watt
RF-Power Amplifiers: 0.8 GHz - 2 GHz
FLG-7A
RF-Power Amplifier
Frequency Range: 0.8GHz - 2GHz
Maximum Output: 7W
FLG-12A
RF-Power Amplifier
Frequency Range: 0.8GHz - 2GHz
Maximum Output: 12W
FLG-25A
RF-Power Amplifier
Frequency Range: 0.8GHz - 2GHz
Maximum Output: 25W
FLG-50A
RF-Power Amplifier
Frequency Range: 0.8GHz - 2GHz
Maximum Output: 50W
FLG-120A
RF-Power Amplifier
Frequency Range: 0.8GHz - 2GHz
Maximum Output: 120W
FLG-200A
RF-Power Amplifier
Frequency Range: 0.8GHz - 2GHz
Maximum Output: 200W
FLG-300A
RF-Power Amplifier
Frequency Range: 0.8GHz - 2GHz
Maximum Output: 300W
FLG-500A
RF-Power Amplifier
Frequency Range: 0.8GHz - 2GHz
Maximum Output: 500W
RF-Power Amplifiers: 0.8 GHz - 3.6 GHz
FLG-10C
RF-Power Amplifier
Frequency Range: 1GHz - 3GHz
Maximum Output: 10W
FLG-30C
RF-Power Amplifier
Frequency Range: 1GHz - 3GHz
Maximum Output: 30W
VLG-40CA
RF-Power Amplifier
Frequency range: 0.8GHz to 3.2GHz
Output Power: 40 Watt
VLG-70CA
RF-Power Amplifier
Frequency range: 0.8GHz to 3.2GHz
Output Power: 70 Watt
VLG-120CA
RF-Power Amplifier
Frequency-range: 0.8GHz to 3.2GHz
Output Power: 120 Watt
VLG-220CA
RF-Power Amplifier
Frequency-range: 0.8GHz to 3.2GHz
Output Power: 220 Watt
VLG-450CA
RF-Power Amplifier
Frequency-range: 0.8GHz to 3.2GHz
Output Power: 450 Watt
VLG-1000CA
RF-Power Amplifier
Frequency-range: 0.8GHz to 3.2GHz
Output Power: 1000 Watt
FLG-9F
RF-Power Amplifier
Frequency Range: 2GHz - 6GHz
Maximum Output: 9W
FLG-15F
RF-Power Amplifier
Frequency Range: 2GHz - 6GHz
Maximum Output: 15W
FLG-30F
RF-Power Amplifier
Frequency Range: 2GHz - 6GHz
Maximum Output: 30W
FLG-50F
RF-Power Amplifier
Frequency Range: 2GHz - 6GHz
Maximum Output: 50W
FLG-100F
RF-Power Amplifier
Frequency Range: 2GHz - 6GHz
Maximum Output: 100W
RF-Power Amplifiers: 2 GHz - 6 GHz
VLG-15F
RF-Power Amplifier
Frequency range: 2GHz to 6GHz
Output Power: 15 Watt
VLG-30F
RF-Power Amplifier
Frequency range: 2GHz to 6GHz
Output Power: 30 Watt
VLG-55F
RF-Power Amplifier
Frequency range: 2GHz to 6GHz
Output Power: 55 Watt
VLG-100F
RF-Power Amplifier
Frequency-range: 2GHz to 6GHz
Output Power: 100 Watt
VLG-180F
RF-Power Amplifier
Frequency-range: 2GHz to 6GHz
Output Power: 180 Watt
RF-Power Amplifiers: 0.7 GHz - 6 GHz
FLG-15G
RF-Power Amplifier
Frequency Range: 0,7GHz - 6GHz
Power output:: 15W
FLG-25G
RF-Power Amplifier
Frequency Range: 0,7GHz - 6GHz
Power output:: 25W
FLG-50G
RF-Power Amplifier
Frequency Range: 0,7GHz - 6GHz
Power output:: 50W
FLG-100G
RF-Power Amplifier
Frequency Range: 0,7GHz - 6GHz
Power output:: 100W
FLG-200G
RF-Power Amplifier
Frequency Range: 0,7GHz - 6GHz
Power output:: 200W
RF-Power Amplifiers: 0.8 GHz - 6 GHz
VLG-40/15G
RF-Power Amplifier
Frequency-range: 0.8GHz to 6GHz
Output Power: 40/15 Watt
VLG-40/30G
RF-Power Amplifier
Frequency-range: 0.8GHz to 6GHz
Output Power: 40/30 Watt
VLG-70/15G
RF-Power Amplifier
Frequency-range: 0.8GHz to 6GHz
Output Power: 70/15 Watt
VLG-70/30G
RF-Power Amplifier
Frequency-range: 0.8GHz to 6GHz
Output Power: 70/30 Watt
VLG-70/55G
RF-Power Amplifier
Frequency-range: 0.8GHz to 6GHz
Output Power: 70/55 Watt
VLG-120/30G
RF-Power Amplifier
Frequency-range: 0.8GHz to 6GHz
Output Power: 120/30 Watt
VLG-120/55G
RF-Power Amplifier
Frequency-range: 0.8GHz to 6GHz
Output Power: 120/55 Watt
VLG-120/100G
RF-Power Amplifier
Frequency-range: 0.8GHz to 6GHz
Output Power: 120/55 Watt
VLG-220/55G
RF-Power Amplifier
Frequency-range: 0.8GHz to 6GHz
Output Power: 220/55 Watt
VLG-220/100G
RF-Power Amplifier
Frequency-range: 0.8GHz to 6GHz
Output Power: 220/100 Watt
Absorbers
PF30
PF30 61x61cm
PF40
PF40 61x61cm
PF60
PF60 61x61cm
Flat Absorbers
Flat absorbers 61x61cmx10cm
Floor walkable absorbers
Floor walk able absorbers 122x61cmx48cm Attenuation: 23 dB min at 500 MHz and 30 dB min at 1GHz
AUDIO- AND VIDEO SYSTEMS
FAS 3.1
EMC hardened Audio system as duplex intercom and audio monitoring for electrical field-strength up to 225V/m, Frequency: 50Hz to 20kHz (HiFi-quality)
FDR-4
DVD-Video Recorder
DVD-Recorder for up to 4 cameras of Type  ECS or FCS
Stores on internal, external HD or on DVD
Possibility to access through Ethernet
Possibility to store videos in dependence of events or special details.
includes  Software
FMC-03
EMC hardened Video system for electrical field strength up to 200V/m, consisting of:
- 1 pc. Color Camera, type FMC-03
- Image format PAL 4:3
- Optical zoom, 40x,
- Resolution 570K Pixel
- Integrated microphone
- 1 pc. Camera-controller, type FBC-03
- optical input for the Video signal
- VGA/DVI-output for the monitor
- Control-buttons for the PAN/TILT unit 
-  1 pc. PAN/TILT-unit type FPT-03, remote-controlled by
camera-controller, type FBC-03
- 2 pc. Battery-pack, type FPB-03 with power-supply
optional: Power-supply, type FPS-03 for fixed installation
- 1 pc. 4,3" Set-up monitor
-  20m optical fiber, simplex, FSMA-FSMA
- 1 pc. Camera tripod
- 1 pc. fiber-optic feed-through for shielded rooms
The Monitor is not included in the delivery. Useable are any VGA/DVI-monitors.
FMC-03HD
EMC hardened Video system for electrical field strength up to 200V/m, consisting of:
'- 1 pc. Color Camera, type FMC-03HD
- Image format PAL 16:9, 30fps
- Optical zoom, 20x,
- Resolution 2 M Pixel
- Integrated microphone
- 1 pc. Camera-controller, type FBC-03
- optical input for the Video signal
- VGA/DVI-output for the monitor
- Control-buttons for the PAN/TILT unit 
-  1 pc. PAN/TILT-unit type FPT-03, remote-controlled by camera-controller, type FBC-03
- 2 pck Battery-pack, type FPB-03 with power-supply
optional: Power-supply, type FPS-03 for fixed installation
- 1 pc. 4,3" Set-up monitor
-  20m optical fiber, simplex, FSMA-FSMA
- 1 pc. Camera tripod
- 1 pc. fiber-optic feed-through for shielded rooms
The Monitor is not included in the delivery. Useable are any VGA/DVI-monitors.
FMC-03/M
EMC hardened Video system for electrical field-strength up to 200V/m, consisting of:
- 1 pc. Color Camera, type FMC-03
- Image format PAL 4:3
- Optical zoom, 40x,
- Resolution 570K Pixel
- Integrated microphone
- 1 pc. Camera-controller, type FBC-03
- optical input for the Video signal
- VGA/DVI-output for the monitor
- Control-buttons for the PAN/TILT unit 
-  1 pc. PAN/TILT-unit type FPT-03, remote-controlled by
camera-controller, type FBC-03
- 2 pc. Battery-pack, type FPB-03 with power-supply
optional: Power-supply, type FPS-03 for fixed installation
- 1 pc. 4,3" Set-up monitor
-  20m optical fiber, simplex, FSMA-FSMA
- 1 pc. Camera tripod
- 1 pc. fiber-optic feed-through for shielded rooms
The Monitor is not included in the delivery. Useable are any VGA/DVI-monitors.
FMC-03HD/M
EMC hardened Video system for electrical field-strength up to 200V/m, consisting of:
- 1 pc. Color Camera, type FMC-03HD
- Image format PAL 16:9, 30fps
- Optical zoom, 20x,
- Resolution 2 M Pixel
- Integrated microphone
-  1 pc. PAN/TILT-unit type FPT-03, remote-controlled by camera-controller, type FBC-03
- 2 pc. Battery-pack, type FPB-03 with power-supply
optional: Power-supply, type FPS-03 for fixed installation
- 1 pc. 4,3" Set-up monitor
-  10m optical fiber, simplex, FSMA-FSMA
-  20m optical fiber, simplex, FSMA-FSMA
- 1 pc. Camera tripod
- 1 pc. fiber-optic feed-through for shielded rooms
The Monitor is not included in the delivery. Useable are any VGA/DVI-monitors.
FMC-TV42
Flat screen TV 42"
inputs: VGA, HDMI, a.o.
resolution: Full-HD (1920x1080)
integrated stereo speakers
TEST-SYSTEM ACC. TO IEC/EN 61000-4-6: CIT-10
CIT-10
Compact Immunity Test System acc. to IEC/ EN 61000-4-6 and similar standards.
Type: CIT-10/25
Frequency range:
Signal Generator:10kHz to 400MHz, resolution: 1Hz
RF-Power-Amplifier: 100kHz to 250MHz
Amplitude modulation:
1Hz to 100kHz, 0 to 100%, resolution 0,5%
Pulse modulation:
1Hz to 100kHz, 10% to 90%, resolution 1%
Amplifier output power: 25W
The compact instrument includes:
- Signal generator
- Function generator
- RF-power amplifier
- RF-Voltage meter
- Cable set
- Control software for tests according EN 61000-4-6
Integrated front panel display
Connection by USB
CIT-10/75
Compact Immunity Test System
acc. to IEC/ EN 61000-4-6 and BCI-tests acc. to ISO 11452-4, MIL-STD-461E CS114, and similar standards
Type: CIT-10/75
Frequency range: 10kHz to 400MHz, resolution: 1Hz
Amplitude modulation:
1Hz to 100kHz, 0 to 100%, resolution 0,5%
Pulse modulation:
1Hz to 100kHz, 10% to 90%, resolution 1%
Amplifier output power: 100kHz - 400MHz, 75W
Integrated front panel display
The compact instrument includes:
- Signal generator
- Function generator
- RF-power amplifier
- RF-Voltage meter
- Directional coupler (optional) and 2-channel power meter for measurement of forward and reverse power
- Cable set
- Control software for tests  acc. to EN 61000-4-6
Connection by USB
CIT-10/75A
Compact Immunity Test System
acc. to IEC/ EN 61000-4-6 and BCI-tests acc. to ISO 11452-4, MIL-STD-461E CS114, and similar standards
Type: CIT-10/75
Frequency range: 10kHz to 400MHz, resolution: 1Hz
Amplitude modulation:
1Hz to 100kHz, 0 to 100%, resolution 0,5%
Pulse modulation:
1Hz to 100kHz, 10% to 90%, resolution 1%
Amplifier output power: 10kHz-250MHz, 75W
Integrated front panel display
The compact instrument includes:
- Signal generator
- Function generator
- RF-power amplifier
- RF-Voltage meter
- Directional coupler (optional) and 2-channel power meter for measurement of forward and reverse power
- Cable set
- Control software for tests  acc. to EN 61000-4-6
Connection by USB
CIT-10/75MIL
Compact Immunity Test System
acc. to IEC/ EN 61000-4-6, Namur, and BCI-tests acc. to MIL-STD-461E CS114, and similar standards
Type: CIT-10/75
Frequency range: 10kHz to 400MHz, resolution: 1Hz
Amplitude modulation:
1Hz to 100kHz, 0 to 100%, resolution 0,5%
Pulse modulation:
1Hz to 100kHz, 10% to 90%, resolution 1%
Amplifier output power: 10kHz-250MHz, 75W
Integrated front panel display
The compact instrument includes:
- Signal generator
- Function generator
- RF-power amplifier
- RF-Voltage meter
- Directional coupler (optional) and 2-channel power meter for measurement of forward and reverse power
- Cable set
- Control software for tests  acc. to EN 61000-4-6
Connection by USB
CIT-10/W
CIT-10/W
acc. to IEC/EN 61000-4-6 and BCI-Tests
acc. to  ISO 11452-4, MIL-STD-461E CS114, and similar standards
Type: CIT-10/ W
(without RF-amplifier, without directional coupler, without 6dB-attenuator)
Frequency range: 10kHz to 400MHz, resolution: 1Hz
Amplitude modulation:
1Hz to 100kHz, 0 to 100%, resolution 0,5%
Pulse modulation:
1Hz to 100kHz, 10% to 90%, resolution 1%
The compact tester contains:
- Signal generator
- Function generator
- RF-voltage meter
- 2-channel power meter for measurement of forward and reverse power
- Cable kit
- Control software for testing acc. to EN 61000-4-6
Display of test data
USB-interface
CIT-DC
Directional Coupler for CIT-10  (internally installed)  for measurement of forward and reverse power.
acc. to standard IEC/ EN 61000-4-6 (V4.0).
For evaluation of compression/ saturation of the test system
Frequency: 10kHz-400MHz
Power: 200W
Coupling: 40dB
DÄM 25W
Attenuator 6dB, 25W consisting of:
1 pc. Attenuator
1 pc. RF-cable BNC (m) - N (m)
1 pc. Adapter BNC (f) - N (m)
DAM 75W
Attenuator 6dB, 75W consisting of:
1 pc. Attenuator
1 pc. RF-cable BNC (m) - N (m)
1 pc. Adapter BNC (f) - N (m)
DAM 100W
Attenuator 6dB, 100W
consisting of:
1 pc. Attenuator
1 pc. RF-cable BNC (m) - N (m)
1 pc. Adapter BNC(f) - N (m)
Additional Attenuator Models on Request
 
CDN´S ACC. TO IEC/EN 61000-4-6 
AF3
Coupling unit acc. to IEC 61000-4-6 for unscreened, non-balanced lines.
Frequency range: 150kHz to 230MHz,
Number of lines: 3
Connector: terminal block
Maximum current:    0,5A
Maximum Voltage: AC 100V, DC 150V
AF3-MC
Coupling unit acc. to IEC 61000-4-6, for unscreened, non-balanced lines.
Frequency range: 150kHz to 230MHz,
Number of lines: 3
Connector: 4mm safety banana jack
Maximum current:    0,5A
Maximum Voltage: AC 100V, DC 150V
AF3-N
Coupling unit acc. to IEC 61000-4-6 for unscreened, non-balanced lines,
Frequency range: 10kHz to 80MHz,
Number of lines: 3
Connector: terminal block
Maximum current:    0,5A
Maximum Voltage: AC 100V, DC 150V
AF4
Coupling unit acc. to IEC 61000-4-6, for unscreened, non-balanced lines,
Frequency range: 150kHz to 230MHz, (Emission 300MHz),
Number of lines: 4
Connector: terminal block
Maximum current:    0,5A
Maximum Voltage: AC 40V, DC 50V
AF4-MC
Coupling unit acc. to IEC 61000-4-6 for unscreened, non-balanced lines,
Frequency range: 150kHz to 230MHz,
Number of lines: 4
Connector: 4mm safety banana jack
Maximum current:  0,5A
Maximum Voltage: AC 40V, DC 50V
AF5
Coupling unit acc. to IEC 61000-4-6 for unscreened, non-balanced lines.
Frequency range: 150kHz to 230MHz, (Emission 300MHz)
Number of lines: 5
Maximum current:    0,5A
Maximum Voltage: AC 40V, DC 50V
AF5-MC
Coupling unit acc. to IEC 61000-4-6 for unscreened, non-balanced lines.
Frequency range: 150kHz to 230MHz,
Number of lines: 5
Connector: 4mm safety banana jack
Maximum current:    1A
Maximum Voltage: 100VAC
AF6
Coupling unit acc. to IEC 61000-4-6 for unscreened, non-balanced lines.
Frequency range: 150kHz to 230MHz, (Emission 300MHz)
Number of lines: 6
Maximum current:    0,5A
Maximum Voltage: AC 40V, DC 50V
AF8
Coupling unit acc. to IEC 61000-4-6 for unscreened, non-balanced lines.
Frequency range: 150kHz to 230MHz, (Emission 300MHz)
Number of lines: 8
Connector: terminal block
Maximum current:    0,5A
Maximum Voltage: AC 40V, DC 50V
AF8-MC
Coupling unit acc. to IEC 61000-4-6 for unscreened, non-balanced lines.
Frequency range: 150kHz to 80MHz,
Number of lines: 8
Connector: safety banana jack
Maximum current: 16A
Maximum Voltage: 250 VAC
CAN-4
Coupling unit acc. to IEC 61000-4-6 for CAN-Bus (4 lines)
Frequency range: 150kHz to 230MHz,
Number of lines: 4
CAN-5
Coupling unit acc. to IEC 61000-4-6 for CAN-Bus (5 lines)
Frequency range: 150kHz to 230MHz,
Number of lines: 5
Maximum Voltage: 50V AC, 50V DC
DVI
Coupling unit acc. to IEC 61000-4-6 for screened cables.
Frequency range: 150kHz to 230MHz,
Number of lines: DVI 24+5pin
EUT/ AE: DVI-f
FIREWIRE
Coupling unit for IEEE 1394 devices (firewire)
Frequency range: 150kHz to 230MHz
Number of lines: 6 + shielding
HDMI
Coupling unit acc. to IEC 61000-4-6 for screened cables.
Frequency range: 150kHz to 230MHz,
Number of lines: HDMI
Maximum current:    0,5A
Maximum Voltage: AC 150V, DC 200V
EUT/ AE: 19-pin HDMI 1.3A
ISN S8
ISN for screened RJ45 or RJ11 connections.
1, 4 or 8 wire, acc. D.11 CISPR 22 Ed.5.2
ISN T8
ISN T8 CAT5 (LCL=65dB) acc. CISPR 22 ed.5.2
figure D.3 for up to 4 pairs UTP
KAL
Universal Calibration Set for CDN's, including 150/50 Ohm converter, standard version useable for CDN's type M1, M2, M3
KAL-AD
Connector adapter in addition to Universal Calibration Set, for CDN Type xx.
KAL-
Connector adapter in addition to universal calibration set, for CDN type AF8-MC
KAL-AE
Universal Calibration Set
includes  50Ohm termination  for CDN's, including 150/50 Ohm converter,  standard version useable for CDN's type  M1, M2, M3
KAL-ANG
Metal Angle. Additional metal angle for calibration set KAL
includes  150/50 Ohm converter for calibration set KAL
KAL-HC
Calibration adapter for CDN´s with high current.
63A/100A including 150/50 Ohm converter
KAL-RES
150/50 Ohm Converter. Additional 150/50 Ohm converter for calibration set KAL
L1
Coupling- Decoupling Unit for unscreened power supply lines, acc. to IEC 61000-4-6
Frequency range: 150kHz to 230MHz,
Number of lines: 1
Maximum current:    16 A
Maximum voltage: AC 250V, DC 400V
Connector: 4mm safety banana jack
L1/32
Coupling- Decoupling Unit for ground lines or supply lines.
Frequency range: 150kHz to 230MHz,
Number of lines: 1
Maximum current:    32 A
Maximum voltage: AC 250V, DC 400V
L2+N/32
Coupling unit acc. to IEC 61000-4-6, for power supply lines.
L1 + L2 + N
Frequency range: 150kHz to 230MHz,
Number of lines: 3
Maximum current:    32A
Maximum Voltage: AC 250V, DC 400V
L3/32
Coupling unit acc. to IEC 61000-4-6, for power supply lines.
L1 + L2 + L3
Frequency range: 150kHz to 230MHz,
Number of lines: 3
Maximum current:    32A
Maximum Voltage: AC 250V, DC 400V
M1
Coupling unit acc. to IEC 61000-4-6, for unscreened power supply lines.
Frequency range: 150kHz to 230MHz,
Number of lines: 1
Connector:         4mm safety banana jack
Maximum current:       0,5 A
Maximum Voltage:      AC 250V, DC 400V
M2/100-HV
Coupling unit acc. to IEC 61000-4-6, for unscreened power supply lines,
Frequency range: 150kHz to 80MHz,
Number of lines: 2
Maximum current:       100A
Maximum Voltage:      600VAC
Connector:          6mm safety banana jack
M2/32
Coupling unit acc. to IEC 61000-4-6, for unscreened power supply lines,
Frequency range: 150kHz to 230MHz,
Number of lines: 2
Maximum current:       32A
Maximum Voltage:      AC 250V, DC 400V
M2/32-HV
Coupling unit acc. to IEC 61000-4-6, for unscreened power supply lines.
Frequency range: 150kHz to 80MHz,
Number of lines: 2
Maximum current:       32A
Maximum Voltage:      600VAC
Connector:          4mm safety banana jack
M2/63-HV
Coupling unit acc. to IEC 61000-4-6, for unscreened power supply lines.
Frequency range: 150kHz to 80MHz,
Number of lines: 2
Maximum current:      63A
Maximum Voltage:     600VAC
Connector:         6mm safety banana jack
M2+M3/32
Coupling unit acc. to IEC 61000-4-6, for power supply lines.
Frequency range: 150kHz to 230MHz,
Number of lines: 2/3 (switchable)
Maximum current:       32A
Maximum Voltage:      AC 250V, DC 400V
M3/100-HV
Coupling unit acc. to IEC 61000-4-6, for unscreened power supply lines.
Frequency range: 150kHz to 80MHz,
Number of lines: 3
Maximum current:    100A
Maximum Voltage:  600VAC
Connector: 6mm safety banana jack
M3/32
Coupling unit acc. to IEC 61000-4-6 for unscreened power supply lines.
Frequency range: 150kHz to 230MHz,
Number of lines: 3
Maximum current:    32A
Maximum Voltage: AC 250V, DC 400V
M3/32-HV
Coupling unit acc. to IEC 61000-4-6 for unscreened power supply lines.
Frequency range: 150kHz to 80MHz,
Number of lines: 3
Maximum current:    32A
Maximum Voltage:  600VAC
Connector: 4mm safety banana jack
M3/32-L
Coupling unit acc. to IEC 61000-4-6 for unscreened power supply lines, L1/L2/L3.
Frequency range: 150kHz to 230MHz,
Number of lines: 3
Maximum current:    32A
Maximum Voltage: AC 250V
Connector: 4mm safety banana jack
M3/32-LN
Coupling unit acc. to IEC 61000-4-6 for unscreened power supply lines, L1/L2/N
Frequency range: 150kHz to 230MHz,
Number of lines: 3
Maximum current:    32A
Maximum Voltage: AC 250V
Connector: 4mm safety banana jack
M3/32-VHV
Coupling unit acc. to IEC 61000-4-6 for unscreened power supply lines.
Frequency range: 150kHz to 80MHz,
Number of lines: 3
Maximum current:    32A
Maximum Voltage:  1000VAC
Connector: 4mm safety banana jack
M3/63-HV
Coupling unit acc. to IEC 61000-4-6 for unscreened power supply lines.
Frequency range: 150kHz to 80MHz,
Number of lines: 3
Maximum current:    63A
Maximum Voltage:  600VAC
Connector: 6mm safety banana jack
M3/32
Coupling unit acc. to IEC 61000-4-6 for power supply lines.
Frequency range: 150kHz to 230MHz,
Number of lines: 3
Maximum current:    32A
Maximum Voltage: AC 250V, DC 400V
M3-L
Coupling unit acc. to IEC 61000-4-6,for unscreened power supply lines, L1/L2/L3
Frequency range: 150kHz to 230MHz
Number of lines: 3
Maximum current:    16A
Maximum Voltage: AC 250V
Connector: 4mm safety banana jack
M4
Coupling unit acc. to IEC 61000-4-6,for unscreened power supply lines,
Frequency range: 150kHz to 230MHz,
Number of lines: 4
Maximum current:    16A
Maximum Voltage: AC 250V
Connector: 4mm safety banana jack
M4/100-HV
Coupling unit acc. to IEC 61000-4-6, for unscreened power supply lines,
Maximum voltage: 600VAC
Frequency range: 150kHz to 80MHz,
Number of lines: 4
Maximum current:    100A
Connector: 6mm safety banana jack
M4/100-LN-HV
Coupling unit acc. to IEC 61000-4-6, for unscreened power supply lines, L1-L2-L3-N
Maximum voltage: 600VAC
Frequency range: 150kHz to 80MHz,
Number of lines: 4
Maximum current:    100A
Connector: 6mm safety banana jack
M4/32
Coupling unit acc. to IEC 61000-4-6, for unscreened power supply lines,
Maximum voltage: 600VAC
Frequency range: 150kHz to 80MHz,
Number of lines: 4
Maximum current:    32A
Connector: 4mm safety banana jack
M4/32-HV
Coupling unit acc. to IEC 61000-4-6 for unscreened power supply lines.
Frequency range: 150kHz to 80MHz,
Number of lines: 4
Maximum current:    32A
Maximum Voltage:  1000VAC
Connector: 4mm safety banana jack
M4/32-LN
Coupling unit acc. to IEC 61000-4-6, for unscreened power supply lines, L1-L2-L3-N
Frequency range: 150kHz to 230MHz,
Number of lines:4
Maximum current:    32A
Maximum Voltage: AC 250V
Connector: 4mm safety banana jack
M4/32-VHV
Coupling unit acc. to IEC 61000-4-6 for unscreened power supply lines.
Frequency range: 150kHz to 80MHz,
Number of lines: 4
Maximum current:    32A
Maximum Voltage:  1000VAC
Connector: 4mm safety banana jack
M4/63-HV
Coupling unit acc. to IEC 61000-4-6, for unscreened power supply lines,
Maximum voltage: 600VAC
Frequency range: 150kHz to 80MHz,
Number of lines: 4
Maximum current:    63A
Connector: 6mm safety banana jack
M4/63-LN-HV
Coupling unit acc. to IEC 61000-4-6, for unscreened power supply lines, L1-L2-L3-N
Maximum voltage: 600VAC
Frequency range: 150kHz to 80MHz,
Number of lines: 4
Maximum current:    63A
Connector: 6mm safety banana jack
M4-LN
Coupling unit acc. to IEC 61000-4-6, for unscreened power supply lines, L1-L2-L3-N
Frequency range: 150kHz to 230MHz,
Number of lines: 4
Maximum current:    16A
Maximum Voltage: AC 250V
Connector: 4mm safety banana jack
M5
Coupling unit acc. to IEC 61000-4-6, for unscreened power supply lines,
Frequency range: 150kHz to 230MHz,
Number of lines: 5
Maximum current:    16A
Connector: 4mm safety banana jack
M5/100-HV
Coupling unit acc. to IEC 61000-4-6, for unscreened power supply lines,
Maximum voltage: 600VAC
Frequency range: 150kHz to 80MHz,
Number of lines: 5
Maximum current:    100A
Connector: 6mm safety banana jack
M5/32
Coupling unit acc. to IEC 61000-4-6, for unscreened power supply lines,
Frequency range: 150kHz to 230MHz,
Number of lines: 5
Maximum current:    32A
Connector: 4mm safety banana jack
M5/32-HV
Coupling unit acc. to IEC 61000-4-6, for unscreened power supply lines,
Maximum voltage: 600VAC
Frequency range: 150kHz to 80MHz,
Number of lines: 5
Maximum current:    32A
Connector: 4mm safety banana jack
M5/32-VHV
Coupling unit acc. to IEC 61000-4-6, for unscreened power supply lines,
Maximum voltage: 1000VAC
Frequency range: 150kHz to 80MHz,
Number of lines: 5
Maximum current:    32A
Connector: 4mm safety banana jack
M5/63-HV
Coupling unit acc. to IEC 61000-4-6, for unscreened power supply lines,
Maximum voltage 600VAC
Frequency range: 150kHz to 80MHz,
Number of lines: 5
Maximum current:    63A
Connector: 6mm safety banana jack
RJ11
Coupling unit acc. to IEC 61000-4-6, with connector RJ11
for unscreened, symmetrical lines;
Frequency range: 150kHz to 230MHz,
Number of lines: 6
Maximum current:    0.25 A
Maximum Voltage: AC 100V eff, DC 150V
RJ45
Coupling unit acc. to IEC 61000-4-6, with connector RJ45
for unscreened, symmetrical used lines;
Frequency range: 150kHz to 230MHz;
Number of lines: 8;
Maximum current:    0.25 A;
Maximum Voltage: AC 100V eff, DC 150V
RJ45-S
Coupling unit acc. to IEC 61000-4-6, with connector RJ45 (8 lines + screen)
for screened lines;
Frequency range: 150kHz to 230MHz,
Maximum current:    0.25 A
Maximum Voltage: AC 100V eff, DC 150V
S1
Coupling unit acc. to IEC 61000-4-6, for screened cables.
Frequency range: 150kHz to 230MHz,
Number of lines: 1
Maximum current:    0,25A
Maximum Voltage: AC 100V, DC 150V
S1/75
Coupling unit acc. to IEC 61000-4-6, for screened cables.
Frequency range: 150kHz to 230MHz,
Number of lines: 1
Maximum current:    0,25A
Maximum Voltage: AC 100V, DC 150V
Impedance: 75 Ohm
Connector: BNC
S15
Coupling unit acc. to IEC 61000-4-6, for screened cables.
Frequency range: 150kHz to 230MHz,
Number of lines: 15
Maximum current:    0,5A
Maximum Voltage: AC 250V, DC 400V
Connector: 15-pol Sub D
S2
Coupling unit acc. to IEC 61000-4-6, for screened cables.
Frequency range: 150kHz to 230MHz,
Number of lines: 2
Maximum current:    0,5A
Maximum Voltage: AC 150V, DC 200V
Connector: XLR
S25
Coupling unit acc. to IEC 61000-4-6, for screened cables.
Frequency range: 150kHz to 230MHz,
Number of lines: 25
Maximum current:    0,5A
Maximum Voltage: AC 250V, DC 400V
Connector: 25 pin Sub-D
S4
Coupling unit acc. to IEC 61000-4-6, for screened cables.
Frequency range: 150kHz to 230MHz,
Number of lines: 4
Maximum current:    0,5A
Maximum Voltage: AC 250V
Con.: 5 pin XLR
S8
Coupling unit acc. to IEC 61000-4-6, for screened cables.
Frequency range: 150kHz to 230MHz,
Number of lines: 8
Maximum current:    0,5A
Maximum Voltage: AC 250V, DC 400V
S9
Coupling unit acc. to IEC 61000-4-6, for screened cables.
Frequency range: 150kHz to 230MHz,
Number of lines: 9
Maximum current:    0,5A
Maximum voltage: AC 150V, DC 200V
Connector: 9 pin Sub-D
S-DIR
Direct coupling on screened cables.
Frequency range: 150kHz to 230MHz,
Connectors: BNC/ crocodile clamp
T2
Coupling unit acc. to IEC 61000-4-6, for unscreened, balanced lines,
Frequency range: 150kHz to 230MHz
Number of lines: 2
Maximum current:    0.5A
Maximum Voltage: AC 150V, DC 200V
Connector: terminal block
T4
Coupling unit acc. to IEC 61000-4-6, for unscreened, balanced lines,
Frequency range: 150kHz to 230MHz,
Number of lines: 4
Maximum current:    0.5A
Maximum Voltage: AC 150V, DC 200V
Connector: terminal block
T6
Coupling unit acc. to IEC 61000-4-6, for unscreened, balanced lines.
Frequency range: 150kHz to 230MHz,
Number of lines: 6
Max. current:    0.5A
Max. Voltage: AC 150V, DC 200V
Connector: RJ45
T8
Coupling unit acc. to IEC 61000-4-6, for unscreened, balanced lines,
Frequency range: 150kHz to 230MHz,
Number of lines: 8
Maximum current:    0.5A
Maximum Voltage: AC 150V, DC 200V
Connector: terminal block
USB-3.0
Coupling unit acc. to IEC 61000-4-6, for test of devices with USB (Compatible to all USB standards up to 3.0)
Frequency range: 150kHz to 230MHz
Maximum Current:          0.9A
Maximum Voltage: AC 100V ; DC 150V
Connectors:
EUT: USB-socket Type A
AE: USB-socket Type A
USB-C
Coupling unit acc. to IEC 61000-4-6, for test of central  devices with USB
Frequency range: 150kHz to 230MHz
Maximum Current:          0.5A
Maximum Voltage: AC 250V ; DC 400V
Connectors:
EUT: USB-socket Type B
AE: USB-socket Type A
USB-P
Coupling unit acc. to IEC 61000-4-6, for test of peripheral  devices with USB
Frequency range: 150kHz to 230MHz
Maximum Current:          0.5A
Maximum Voltage: AC 250V ; DC 400V
Connectors:
EUT: USB-socket Type A
AE: USB-socket Type B
CDN´S ACC. TO IEC/EN 61000-4-6 - NAMUR
AF2-N
Coupling network acc. to IEC 61000-4-6 Namur for unscreened, non-balanced lines,
Frequency range (Coupling): 10kHz - 230MHz,
Number of lines: 2, Maximum Current: 0,5 A,
Maximum Voltage: AC 40V, DC 50V
Connector: Safety banana jack
AF4-N
Coupling network acc. to IEC 6100-4-6 Namur for unscreened, non-balanced lines,
Frequency range (Coupling): 10kHz - 80MHz,
Number of lines: 4,
Maximum Current: 0.5 A,
Maximum Voltage: AC 40V, DC 50V
Connector: 4mm safety banana jack
AF8-N
Coupling network acc. to IEC 6100-4-6 Namur for unscreened, non-balanced lines,
Frequency range (Coupling): 10kHz - 230MHz,
Number of lines: 8,
Connector: 9-pol Sub-D
M1-N
Coupling network acc. to IEC 61000-4-6 Namur for unscreened power supply lines,
Frequency range (Coupling): 10kHz - 230MHz,
Number of lines: 1,
Maximum Current: 0.5A,
Maximum Voltage: AC 250V, DC 400V
Connector: 4mm safety banana jack
M2+M3-N
Coupling network acc. to IEC 6100-4-6 Namur for unscreened power supply lines,
Frequency range (Coupling): 10kHz - 230MHz,
Number of lines: 2/ 3, switchable
Maximum Current: 16A,
Maximum Voltage: AC 250V, DC 400V
Connector: 4mm safety banana jack
M2-N
Coupling network acc. to IEC 61000-4-6 Namur for unscreened power supply lines,
Frequency range (Coupling): 10kHz - 230MHz,
Number of lines: 2,
Maximum Current: 16A,
Maximum Voltage: AC 250V, DC 400V
Connector: 4mm safety banana jack
M3-N
Coupling network acc. to IEC 6100-4-6 Namur for power supply lines,
Frequency range (Coupling): 10kHz - 80MHz,
Number of lines: 3, Maximum Current: 16A,
Maximum Voltage: AC 250V, DC 400V
M4/32-N
Coupling network acc. to IEC 61000-4-6 Namur for unscreened power supply lines,
Frequency range (Coupling): 10kHz - 230MHz,
Number of lines: 4,
Maximum Current: 32A,
Maximum Voltage: AC 250V
Connector: 4mm safety banana jack
M5-N
Coupling network acc. to IEC 61000-4-6 Namur for power supply lines,
Frequency range: 10kHz to 80MHz,
Number of lines: 5
Maximum current:    16A
RJ45-S-N
Coupling unit acc. to IEC 61000-4-6, acc. Namur for screened cables.
Frequency range: 10kHz to 230MHz,
Number of lines: 8 + screen
Maximum current:    0,5A
Maximum Voltage: AC 150V, DC 200V
S2-N
Coupling unit acc. to IEC 61000-4-6 acc. Namur for screened cables.
Frequency range: 10kHz to 230MHz,
Number of lines: 8 + screen
Maximum current:    0,5A
Maximum Voltage: AC 150V, DC 200V
S9-N
Coupling unit acc. to IEC 61000-4-6, Namur for screened cables.
Frequency range: 10kHz to 230MHz,
Number of lines: 9
Maximum current:    0.5A
Maximum Voltage: AC 150V, DC 200V
Connector: 9 pin Sub-D
T2-N
Coupling network acc. to IEC 61000-4-6 for unscreened, balanced lines.
Frequency range: 10kHz - 80MHz,
Number of lines: 2, Maximum Current: 0.5 A,
Maximum Voltage: AC 150V, DC 200V
Connector: terminal block
T4-N
Coupling network acc. to IEC 61000-4-6 Namur for unscreened, balanced lines,
Frequency range (Coupling): 10kHz - 80MHz,
Number of lines: 4, Maximum Current: 0.5 A,
Connector: terminal block
USB-C-N
Coupling unit acc. to IEC 61000-4-6, acc. to Namur for test of central devices with USB
Frequency range: 10kHz - 230MHz
Maximum Current:          0.5A
Maximum Voltage: AC 150V ; DC 200V
Connector:
EUT: USB-socket Type B
AE: USB-socket Type A
USB-P-N
Coupling unit acc. to IEC 61000-4-6, acc. to Namur for test of peripheral  devices with USB
Frequency range: 10kHz - 230MHz
Maximum Current:          0,5A
Maximum Voltage: AC 150V ; DC 200V
Connectors:
EUT: USB-socket Type A
AE: USB-socket Type B
CDN´S ACC. TO IEC/EN 61000-4-6 + EN 55015 / EN 55022
 
AF2
Coupling unit acc. to IEC 61000-4-6, EN 55015 and EN 55022 for unscreened, non-balanced lines.
Frequency range: 150kHz to 300MHz
Number of lines: 2
Connector: terminal block
Maximum current:    0,5A
Maximum Voltage: AC 40V, DC 50V
AF2-MC
Coupling unit acc. to IEC 61000-4-6, EN 55015 and EN 55025 for unscreened, non-balanced lines.
Frequency range: 150kHz to 300MHz,
Number of lines: 2
Connectors: 4mm safety banana jack
Maximum current:    0,5A
Maximum Voltage: AC 40V, DC 50V
M2
Coupling unit acc. to IEC 61000-4-6, EN 55015 and EN 55022 for unscreened power supply lines.
Frequency range: 150kHz to 230MHz (Emission up to 300MHz),
Number of lines: 2
Maximum current:    16A
Maximum Voltage: AC 250V, DC 400V
Connector: 4mm safety banana jack
M2+M3
Coupling unit acc. to IEC 61000-4-6, EN55022 and EN55015 for unscreened power supply lines.
Frequency range: 150kHz to 230MHz (Emission up to 300MHz),
Number of lines: 2/3 (switchable)
Maximum current:    16A
Maximum Voltage: AC 250V, DC 400V
Connector: 4mm safety banana jack
M3
Coupling unit acc. to IEC 61000-4-6, EN 55015 and EN 55022 for unscreened power supply lines.
Frequency range: 150kHz to 230MHz (Emission up to 300MHz),
Number of lines: 3
Maximum current:    16A
Maximum Voltage: AC 250V, DC 400V
Connector: 4mm safety banana jack
EM COUPLING CLAMP / DECOUPLING CLAMP - BCI CLAMP
EMCL
Coupling clamp acc. to IEC 61000-4-6
Frequency range: 100kHz to 1000MHz,
Maximum diameter: 20mm
Connector: N-female
Maximum RF input power:
150KHz to 100MHz: 100W Maximum 15 min.
100MHz to  230MHz: 100W  Maximum  5 min.
230MHz to 1000MHz:  50W Maximum   3 min.
includes  calibration kit type KAL-EMCL
2 pc. (150/50 Ohm adapter)
1 pc. calibration cable
1 pc. 50 ohms- termination (N)
1 pc. adapter BNC (f)-N(m)
EMCL-35
Coupling clamp acc. to IEC 61000-4-6
Frequency range: 100kHz to 1000MHz (10kHz as an option)
Maximum diameter: 37mm
Connector: N-female
Maximum RF input power:
150KHz to 100MHz: 100W Maximum 15 min.
100MHz to  230MHz: 100W  Maximum  5 min.
230MHz to 1000MHz:  50W Maximum   3 min.
includes  calibration kit type KAL-EMCL
2 pc. (150/50 Ohm adapter)
1 pc. calibration cable
1 pc. 50 ohms- termination (N)
1 pc. adapter BNC (f)-N(m)
EMCL-MN10K
Matching network for EM coupling clamp  type EMCL.
Frequency range: 10kHz - 150kHz
KAL-EMCL
Calibration unit for coupling clamp, acc. to IEC 61000-4-6
Frequency range: 150kHz to 1000MHz,
Maximum diameter: 20mm
Maximum RF input power:
150KHz to 1000MHz: 100W Maximum 15 min.
100MHz to  230MHz: 100W  Maximum  3 min.
230MHz to 1000MHz:  50W Maximum   3 min.
includes  calibration kit type KAL-EMCL
2 pc. (150/50 Ohm adapter)
1 pc. calibration cable
1 pc. 50 ohms- termination (N)
1 pc. adapter BNC (f)-N(m)
BCI-CLAMP-2
Current Injection Clamp 10kHz-400MHz for BCI-tests acc. to ISO 11452-4,
MIL-STD-461, ...
Frequency range:
10kHz - 400MHz
Frequency/ Insertion loss
10kHz/ 45dB, 100kHz/ 25dB, 800kHz/ 9dB, 1MHz/ 7,5dB, 10MHz/ 6dB, 100MHz/6dB, 200MHz/ 7dB, 300MHz/ 9dB, 400MHz/ 11dB
Maximum input power:
45 min @ 100W
90 min @ 70W
Diameter (outer): 120mm
Diameter (inner): 40mm
Width: 40mm
Clamp can be opened/ closed
includes  calibration jig
BCI-ACC
BCI-Accessories
1pc TER 50: Termination 50 ohms
1 pc ATT30: Attenuator 30dB, 50ohms
MP-50
Current monitoring probe MP-50 for conducted immunity measurements acc. to IEC/EN 61000-4-6, BCI-tests acc. to ISO 11452-4, RTCA/DO-160 section 20, MIL-STD-461 and various automotive standards
Frequency range: 10 kHz - 400 MHz
Insertion impedance: < 2.5 Ohm
Maximum signal current (10 kHz - 400 MHz): 1 A
Inner cable diameter: 46 mm
Outer diameter of the probe: 115 mm
Thickness of the probe: 30 mm
Overall length of the probe: 136 mm
Weight: 0.55 kg
Individual calibration data are delivered with each probe.
TEST-SYSTEM ACC. TO IEC/EN 61000-4-16 / PSG-300
PSG-300
Power Signal Generator
Type PSG-300/ 260W
DC, 0.05Hz - 300kHz, sine, rectangle, ramp.
100V/us; +-50V; +-5A; k<0.1%; for continuous and short disturbing voltages up to 50V
acc. to EN/ IEC 61000-4-16.
External Generator input for optional connection of external voltage sources for generation of higher test voltage levels.
USB;
System software: WIN NT/2000/XP.
PSG-300A
Power Signal Generator
Type: PSG-300/ 600W
DC, 0.05Hz - 300kHz, sine, rectangle, ramp.
100V/us; +-50V; +-12A (typ. 15A); k<0.1%;
Maximum output power: 600W typ. 800W for continuous and short disturbing voltages up to 50V
acc. to EN/ IEC 61000-4-16.
External Generator input for optional connection of external voltage sources for generation of higher test voltage levels.
USB;
System software: WIN NT/2000/XP.
PSG-E300
Option: Extension to 300V of PSG-300
DC (0Hz), 16 2/3Hz, 50Hz, 60Hz
External voltage source for generation of short term levels of  IEC/ EN 61000-4-16 in connection with instruments of series PSG/ MTS at technical frequencies DC (0Hz),16 2/3Hz, 50Hz, 60Hz up to 300V. Maximum time 10s.
USB
includes  system software
PSG-EXT
Input connector for phase controlled switching of external power source (any brand)
ITU-16
Coupling network acc. to ITU_T K54/fig.1
Fused at power frequencies 16 2/3Hz,50Hz, 60Hz
Connector: terminal block
PSG-SHUNT
Current shunt acc. to IEC/EN 61543
PSG-U/I
Option: Voltage/ Current Measurement for Magnetic Field Tests
acc. to MIL-STD-461 CS101 and EN55103-2
includes  application software
PSG-ZDDIFF
Current shunt acc. to EN 61000-4-19 (Draft) Annex C; Figure C3
CDN´S ACC. TO IEC/EN 61000-4-16
AF2-16
Coupling unit acc. to IEC 61000-4-16, for unscreened, non-balanced lines.
Frequency range: DC/15Hz to 150kHz,
Number of lines: 2
Maximum current:    0.5A
Maximum Voltage: AC 40V, DC 50V
Connector: terminal block
AF4-16
Coupling unit acc. to IEC 61000-4-16, for unscreened, non-balanced lines.
Frequency range: DC/15Hz to 150kHz,
Number of lines: 4
Maximum current:    0.5A
Maximum Voltage: AC 40V, DC 50V
Connector: terminal block
AF8-16
Coupling unit acc. to IEC 61000-4-16, for unscreened, non-balanced lines.
Frequency range: DC/15Hz to 150kHz,
Number of lines: 8
Maximum current:    0,5A
Maximum Voltage: AC 40V, DC 50V
Connector: terminal block
CN-50065-2-1
Coupling unit acc. to EN 50065-2-1, 7.2.2
Frequency range: 3kHz bis 30MHz
Test level: 134dBµV (5V) cont.
Number of lines: 2 (N+L)
Maximum voltage: AC 250V
Connection ports:
Input: BNC
Output: 4mm MC
M2/DC-16
Coupling unit acc. to IEC 61000-4-6 for unscreened power supply lines.
Frequency range: DC
Test level: 50V cont.
Number of lines: 2
Voltage/Current: 50V/32A
Connector: 4mm banana safety jack
M2+M3-16
Coupling unit acc. to IEC 61000-4-16, for unscreened power supply lines.
Frequency range: DC/ 15Hz to 150kHz
Number of lines: 2/3 switchable
Maximum current:    32A
Maximum Voltage: 520VAC / 620 VDC
Connector: 4mm safety banana jack
 
M2-16
Coupling unit acc. to IEC 61000-4-16, for unscreened power supply lines.
Frequency range: 15Hz to 150kHz
Test level: 50V cont.
300V (1s) at energetically used frequencies
Number of lines: 2
Maximum current:    32A
Maximum Voltage: AC 250V
(50VDC, 32A)
Connector: 4mm safety banana jack
M2345/125-16
Coupling unit acc. to IEC/ EN 61000-4-16
Switchable between modes M2/ M3/ M4/ M5 for power supply lines.
Frequency range: DC, 15Hz to 150kHz
Maximum test level: 300V cont.
Number of lines: 2, 3, 4, 5 switchable
Maximum current:    125A
Connection: 6mm MC socket
Stand-alone and remote controllable
M2345/32-16
Coupling unit acc. to IEC/ EN 61000-4-16
Switchable between modes M2/ M3/ M4/ M5 for power supply lines.
Frequency range: DC, 15Hz to 150kHz
Maximum test level: 300V cont.
Number of lines: 2, 3, 4, 5 switchable
Maximum current:    32A
Stand-alone and remote controllable
M3/DC-16
Coupling unit acc. to IEC 61000-4-16, for unscreened power supply lines.
Frequency range: DC
Test level: 50V cont.
Number of lines: 3
Voltage/Current: 50V/32A
Connector: 4mm safety banana jack
M3-16
Coupling unit acc. to IEC 61000-4-16, for unscreened power supply lines.
Frequency range: 15Hz to 150kHz,
Number of lines: 3
Maximum current: 32A
Connector: 4mm safety banana jack
M4-16
Coupling unit acc. to IEC 61000-4-6 for unscreened power supply lines.
Frequency range: 15Hz to 150kHz
Test level: 50V cont.
300V (1s) at energetically used frequencies
Number of lines: 4
Maximum current:    32A
Connector: 4mm terminal block
M5-16
Coupling unit acc. to IEC 61000-4-16, for power supply lines.
Frequency range:15Hz to 150kHz
Test level: 50V cont.
300V (1s) at energetically used frequencies
Number of lines: 5
Maximum current:    32A
Connector: 4mm terminal block
RJ45-16
Coupling unit acc. to IEC 61000-4-16, with connector RJ45; for unscreened, non-balanced lines
Frequency range: DC/15Hz to 150kHz
Number of lines: 8;
Maximum current:  0.5 A;
Maximum voltage: AC 40V, DC 50V
T2-16
Coupling unit acc. to IEC 61000-4-16, for unscreened, balanced lines.
Frequency range: DC/15Hz to 150kHz,
Number of lines: 2
Maximum current:    0,5A
Maximum Voltage: AC 150V, DC 200V
Connector: terminal block
T4-16
Coupling unit acc. to IEC 61000-4-16, for unscreened, balanced lines.
Frequency range: DC/15Hz to 150kHz,
Number of lines: 4
EUT / AE-port: Maximum current 0.5A
Maximum voltage: 50V
Connector: terminal block
T8-16
Coupling unit acc. to IEC 61000-4-16, for unscreened, balanced lines.
Frequency range: DC/15Hz to 150kHz,
Number of lines: 8
EUT / AE-port: Maximum current 0.5A
Maximum voltage: 50V
Connector: terminal block
MAGNETIC FIELD TEST SYSTEM - MTS-800 & ACCESSORIES
HC-VER
Transport box for Helmholtz coil
IT-16
Isolation Transformer
Power: 3680VA
Primary voltage: 230V
Secondary voltage: 230V
Secondary current: 16A
Differential/ Common-Mode attenuation
(15Hz ..150kHz): 60dB
Isolation: -1kV (50Hz/ 60Hz)
acc. to IEC/ EN 61000-4-16
IT-20
Isolation Transformer
Power: 4600VA
Primary voltage: 230V
Secondary voltage: 230V
Secondary current: 20A
Differential/ Common-Mode attenuation
(15Hz ..150kHz): 60dB
Isolation: -1kV (50Hz/ 60Hz)
acc. to IEC/ EN 61000-4-16
Weight: 50kg
IT-6
Isolation Transformer
Power: 1380VA
Primary voltage: 230V
Secondary voltage: 230V
Secondary current: 6A
Differential/ Common-Mode attenuation
(15Hz ..150kHz): 60dB
Isolation: -1kV (50Hz/ 60Hz)
acc. to IEC/ EN 61000-4-16
LS-040
40mm Coil
acc. to MIL-STD-461E (RE101)
includes  cable, 3m
LS-133
133mm Coil
acc. to MIL-STD-461E (RE101)
includes  cable 3m
BC-500
Large field coil for immunity tests acc. to EN 55103
Diameter: 500mm
includes  cable 3m
MTS-KN
Calibration network acc. to  EN55103-2, picture B2
MTS-KOM
Compensation board for MTS-800
(add-on kit)
for compensation of the coil inductivity
of optional available Helmholtz-coils
HCS-50/28 and HCST-50/28
to meet 1000A/m at 1kHz.
MTS-KUR
Option: Short time field
Maximum input 25A
MTS-PA
Common mode test adapter
acc. to  EN55103-2, picture B1
MTS-ST
Current transducer includes  correction network
acc. to  EN55103-2, picture B4
MTS-STE
External Transformer
for the generation of short term fields
according to IEC/EN 61000-4-8

Primary: 230V
Secondary: 0-260V
Maximum Current: 20A
RL-120
120mm Coil
acc. to  MIL-STD-461E (RS101)
includes  Cable, 3m
RLS-133
133mm Coil
acc. to EN 55103
includes  Cable, 3m
Software
 
SW-4/16
Software module, EN 61000-4-16
Windows-Software for measurements according
to EN 61000-4-16.
Plug-in for MTS-800 system software.
SW-CE101
Software module, MIL-STD-461E (CE101)
Windows-Software for measurements according
to MIL-STD-461E / CE101.
Plug-in for MTS-800 system software.
SW-CS101
Software module, MIL-STD-461E (CS101)
Windows-software for measurements according to
MIL-STD-461E / CS101.
Plug in for MTS-800 system software.
Only usable with coupling transformer CT-50A/C
SW-CS109
Software module, MIL-STD-461E (CS109)
Windows-Software for measurements according
to MIL-STD-461E / CS109.
Plug-in for MTS-800 system software.
Coupling NetworkS
CT-2.5/50A/C
Coupling network for tests acc to
DO-160 Section 18
For these test MTS-800 (optional)  is requested.
includes
resistor (active cooled)
difference amplifier
connector power supply, cables,
and software modification in software of MTS-800
CT-50A/C
Coupling Transformer
Coupling Transformer, type CT2,5/50A
according to MIL-STD-461E (CS101)
for measurements with magnetic
field test system MTS-800.
Maximum current: 15A (primary),
50A (secondary).
Frequency range:
15Hz to 250kHz.
Inclusive Resistor 0,5 Ohm,
100W (active cooling) and
amplifier, with power adapter and cabling.
DO160 chapter 18, boxed , 4mm MC-sockets
CT-ISS-19
Coupling network for tests acc to

DO-160 Section 19 (19.3.1, 19.3.2, 19.3.3)

For these test MTS-800 (optional)  is requested.

includes  connector power supply, cables and software
EMC CONTROL UNIT - ECU
 
ECU-3
Compact EMC Control Unit - Basic Instrument
Frequency range: 9kHz - 3GHz
for radiated and conducted immunity tests and emission measurements
Supports test according following standards:
IEC/ EN 61000-4-3, -6, ISO 11452-2, -3, -4, -5,
MIL-STD 461, RS103, RE102 and emission Standards
Includes following instruments/ functions:
-Signal generator: 9kHz - 3GHz,
- Frequency resolution: 0,1Hz
- Signals output (modulation): CW, AM, PM
- Output level:-65dBm to +10dBm
- Resolution of output level: 0,1dB
-2 internal RF-switching relay (type: 1 I/O to 3 O/I)
for switching signal generator output to inputs of 3 amplifiers and outputs of 3 amplifiers to antenna load 1
-2 Monitoring inputs, type EUT-Fail, TTL/CMOS compatible
-2 Monitoring inputs, type analogue measuring input, 0-10V
-Interlock input connectable to an external switching relay,  with LED (Reset with or without manual confirmation at Reset button)
-switching to emission path and connection of 1 measuring receiver/ spectrum analyzer
-Display of set paths at front panel
-Display of frequency, generator level, modulation,
degree of modulation, modulation on/ off
-LED RF-generator on/ off
-3 USB sockets for connection of additional external instruments as for example field meters, millimeters, …
-driver for insertion into Control software
-Applicable with Frankonia software:
RF-LAB, CD-LAB, BCI-LAB
-Dimension: 449mm x 177mm (4 HE) x 580mm
-Weight: about 15kg
-PC-interface: USB, GPIB
-19"-Rack version
Optional available:
ECU-OUT2: Switching between 2 outputs Antenna/ Load
ECU-OUT3: Switching between 3 outputs Antenna/ Load
ECU-REC2: Switching to emission path and connection of 2 measuring receivers/ spectrum analyzers
Power meter/ RF-Millivoltmeter
ECU-PM1 Measuring inputs: 10kHz-500MHz (For/ Rev. Power)
ECU-PM1 Measuring input: 10kHz-500MHz  (RF-voltage)
ECU-PM2 Measuring inputs: 100kHz-6GHz (For/ Rev. Power)
Internal directional couplers (Maximum 3):
ECU-DC1A: 10kHz -250MHz, 30dB, 100W
ECU-DC1B: 10kHz-400MHz, 30dB, 100W
ECU-DC1C: 10kHz-250W, 40dB, 500W
ECU-DC2: 80MHz-1000MHz, 50dB, 1500W
ECU-DC3: 1GHz-4GHz, 40dB, 600W
ECU-EXPM: External modulation input for generation of pulsed signals
ECU-120dBm Output level from -120dBm
ECU-LAN: additional PC-interface LAN
ECU-6
Compact EMC Control Unit - Basic Instrument
Frequency range: 9kHz - 6GHz
for radiated and conducted immunity tests and
emission measurements
Supports test according following standards:
IEC/ EN 61000-4-3, -6, ISO 11452-2, -3, -4, -5,
MIL-STD 461, RS103, RE102 and emission standards
Includes following instruments/ functions:
-Signal generator: 9kHz - 6GHz,
- Frequency resolution: 0,001Hz
- Signals output (modulation): CW, AM, PM, FM
- Output level:-65dBm to +13dBm
- Resolution of output level: 0,1dB
-2 internal RF-switching relay (type: 1 I/O to 4 O/I)
for switching signal generator output to inputs of 4 amplifiers and outputs of 4 amplifiers to antenna load 1
-2 Monitoring inputs, type EUT-Fail, TTL/CMOS compatible
-2 Monitoring inputs, type analogue measuring input, 0-10V
-Interlock input connectable to an external switching relay,
with LED (Reset with or without manual confirmation at reset button)
-switching to emission path and connection of
1 measuring receiver/ spectrum analyzer
-Display of set paths at front panel
-Display of frequency, generator level, modulation,
degree of modulation, modulation on/ off
-LED RF-generator on/ off
-3 USB sockets for connection of additional external instruments as
for example field meters, millimeters, ...
-driver for insertion into Control software
-Applicable with Frankonia software:
RF-LAB, CD-LAB, BCI-LAB
-Dimension: 449mm x 177mm (4 HE) x 580mm
-Weight: about 15kg
-PC-interface: USB, GPIB
-19"-Rack version

Optional available:
ECU-OUT2: Switching between 2 outputs Antenna/ Load
ECU-OUT3: Switching between 3 outputs Antenna/ Load
ECU-REC2: Switching to emission path and connection of
2 measuring receivers/ spectrum analyzers 
Power meter/ RF-Millivoltmeter
ECU-PM1 Measuring inputs: 10kHz-500MHz (For/ Rev. Power)
ECU-PM1 Measuring input: 10kHz-500MHz  (RF-voltage)
ECU-PM2 Measuring inputs: 100kHz-6GHz (For/ Rev. Power)
Internal directional couplers (Maximum 4):
ECU-DC1A: 10kHz -250MHz, 30dB, 100W
ECU-DC1B: 10kHz-400MHz, 30dB, 100W
ECU-DC1C: 10kHz-250W, 40dB, 500W
ECU-DC2: 80MHz-1000MHz, 50dB, 1500W
ECU-DC3: 1GHz-4GHz, 40dB, 600W
ECU-DC4: 2GHz-8GHz, 40dB, 600W
ECU-EXPM: External modulation input for generation of pulsed signals
ECU-120dBm: Output level from -120dBm
ECU-LAN: additional PC-interface LAN 
ECU-120DBM
Option for ECU-3/6
Output level from -120dBm
ECU-DC1A
Option for ECU-3/6
ECU-DC1A: Directional coupler,10kHz -250MHz, 30dB, 100W
ECU-DC1B
Option for ECU-3/6
ECU-DC1B: Directional coupler, 10kHz-400MHz, 30dB, 100W
ECU-DC1C
Option for ECU-3/6
ECU-DC1C: Directional coupler,10kHz-400MHz, 40dB, 500W
ECU-DC2
Option for ECU-3/6
ECU-DC2: Directional coupler, 80MHz-1000MHz, 50dB, 1500W
ECU-DC3
Option for ECU-3/6
ECU-DC3: Directional coupler,1GHz-4GHz, 40dB, 600W
ECU-DC34
Directional Coupler, type C8000
Frequency Range: 600MHz to 6GHz
Coupling: 30dB
Maximum Input Power: 100 Watt
ECU-DC3B
Option for ECU-3/6
ECU-DC3: Directional coupler,0,8GHz-4,2GHz, 40dB, 600W
ECU-DC4
Option for ECU-6
ECU-DC4: Directional coupler, 2GHz-8GHz, 40dB, 600W
ECU-EXPM
Option for ECU-3/6 ECU-EXPM: External modulation input for generation of pulsed signals
e.g. radar pulses acc. to automotive standards
(This option requires an optional external LF-generator)
ECU-KS2
Cable-set and GPIB-interface for immunity test systems with 2 amplifiers. Consisting of:
1pc. "National Instruments" GPIB-interface
1set  Bus cable and RF-cables
The Control-PC is not included.
ECU-KS3
Cable-set and GPIB-interface for immunity test systems with 3 amplifiers. Consisting of:
1pc. "National Instruments" GPIB-interface
1set  Bus cable and RF-cables
The Control-PC is not included.
ECU.KS4
Cable-set and GPIB-interface for immunity test systems with 4 amplifiers. Consisting of:
1pc. "National Instruments" GPIB-interface
1set  Bus cable and RF-cables
The Control-PC is not included.
ECU-LAN
Option for ECU-3/6
ECU-LAN: additional interface: LAN
ECU-LWL-U1
Fiber Optical Transmission Line for analogue voltage signals for connection with ECU-3/6
Especially hardened for application in EMI-measurements and EMS-tests
Transmitting voltage: 0 to 10V
consisting of
2 pcs transceiver (battery supplied) integrated into shielded box
with rubber protection
Channels: 1
Battery supply: 5 pc NiMH-batteries, 4Ah
Operation time: >30h
5-pin charging connector
Dimension per unit: 136mm x 86mm x 65mm
Weight: 800g
1 pc   20m optical fiber FSMA/ duplex multimode fiber 62.5/125µm
2 pc   Power charger
Optional available (not included):
PS-11E (no extra costs) Permanent power supply of transceiver, which is used outside the shielded room, instead of internal batteries and charger
PS-12E External RF-shielded power supply
PS-AKKU external battery pack
External filter depending on application
ECU-OUT2
Option for ECU-3/6
ECU-OUT2: Switching between 2 outputs antenna/ load
ECU-OUT3
Option for ECU-3/6
ECU-OUT3: Switching between 3 outputs Antenna/ Load
ECU-PM1
Option for ECU-3/6
ECU-PM1: Power meter/ RF-milli-voltmeter,
10kHz-500MHz, 2 channel
ECU-PM1A
Option for ECU-3/6
ECU-PM1A: Power meter/ RF-milli-voltmeter,
10kHz-500MHz, 1 channel
ECU-PM2
Option for ECU-3/6
ECU-PM2: Power meter/ RF-milli-voltmeter,
100kHz-6GHz, 2 channel
ECU-PM2A
Option for ECU-3/6 ECU-PM2: Power meter/ RF-milli-voltmeter,  100kHz-6GHz, 1 channel
ECU-PM2B
Option for ECU-3/6 ECU-PM2: Power meter/ RF-milli-voltmeter,  10kHz-1GHz, 1 channel
ECU-REC2
Option for ECU-3/6
ECU-REC2: Connection of
2 measuring receivers/ spectrum analyzer
ECU-SW6
Option for ECU-3/6 ECU-SW6: Standard-software for testing acc. to IEC/ EN 61000-4-6 
ECU-WARN
Option for ECU-3/6 ECU-WARN: Change circuit  for control of an optional red/ green light system to signalize following status:
1. status:  No test (Generator off)-Door opening allowed
2. status:
Test (Generator on)- Door opening forbidden/
XLR-Connector (1-COM-2)
Maximum rated values: 230V AC/DC, 200mA
RF-RELAY-SWITCHING UNITS - RSU
RSU 0213
RF Switching Box with 1 Relays (1x3) for computer-controlled switching of RF-signals for EMC-applications in the frequency-range DC...12GHz.
Operation:
1. Manual operation
2. PC-controlled by IEEE 488 and RS232-interface
LED-Display of switching status
Quantity of switching relays: 1
Switching from 1 input to 3 outputs (1x3)
RSU 0223
RF Switching Box with 2 Relays (1x3)
for computer-controlled switching
of RF-signals for EMC-applications
in the frequency-range DC...12GHz.
Operation:
1. Manual operation
2. PC-controlled by IEEE 488 and RS232-interface
LED-Display of switching status
Quantity of switching relays: 2
Switching from 1 input to 3 outputs (1x3)
RSU 0233
RF Switching Box with 3 Relays (1x3)
for computer-controlled switching
of RF-signals for EMC-applications
in the frequency-range DC...12GHz.
Operation:
1. Manual operation
2. PC-controlled by IEEE 488 and RS232-interface
LED-Display of switching status
Quantity of switching relays: 3
Switching from 1 input to 3 outputs (1x3)
RSU 0243
RF Switching Box with 4 Relays (1x3)
for computer-controlled switching
of RF-signals for EMC-applications
in the frequency-range DC...12GHz.
Operation:
1. Manual operation
2. PC-controlled by IEEE 488 and RS232-interface
LED-Display of switching status
Quantity of switching relays: 4
Switching from 1 input to 3 outputs (1x3)
RSU 1203
RF Switching Box with 1 Relay (1x2)
for computer-controlled switching
of RF-signals for EMC-applications
in the frequency-range DC...12GHz.
Operation:
1. Manual operation
2. PC-controlled by IEEE 488 and RS232-interface
LED-Display of switching status
Quantity of switching relays: 1
Switching from 1 input to 2 outputs (1x2)
RSU 1203-40
RF Switching Box with 1 Relay (1x2)
for computer-controlled switching
of RF-signals for EMC-applications
in the frequency-range DC...40GHz.
Connector: SMA 2.9 (10W@40GHz)
Operation:
1. Manual operation
2. PC-controlled by IEEE 488 and RS232-interface
LED-Display of switching status
Quantity of switching relays: 1
Switching from 1 input to 2 outputs (1x2)
RSU 1213
RF Switching Box with 4 Relays
1 (1x2), 1 (1x3)
for computer-controlled switching
of RF-signals for EMC-applications
in the frequency-range DC...12GHz.
Operation:
1. Manual operation
2. PC-controlled by IEEE 488 and RS232-interface
LED-Display of switching status
Quantity of switching relays: 1
1 is switching from 1 input to 2 outputs (1x2)
1 are switching from 1 input to 3 outputs (1x3)
RSU 1223
RF Switching Box with 5 Relay
1 (1x2), 2 (1x3)
for computer-controlled switching
of RF-signals for EMC-applications
in the frequency-range DC...12GHz.
Operation:
1. Manual operation
2. PC-controlled by IEEE 488 and RS232-interface
LED-Display of switching status
Quantity of switching relays: 3
1 are switching from 1 input to 2 outputs (1x2), 2 are switching from 1 input to 3 outputs (1x3)
RSU 1233
RF Switching Box with 4 Relays
for computer-controlled switching
of RF-signals for EMC-applications
in the frequency-range DC...12GHz.
Operation:
1. Manual operation
2. PC-controlled by IEEE 488 and RS232-interface
LED-Display of switching status
Quantity of switching relays: 4
from this:
1 is switching from 1 input to 2 outputs (1x2)
3 are switching from 1 input to 2 outputs (1x3)
RSU 2203
RF Switching Box with 2 Relays (1x2)
for computer-controlled switching
of RF-signals for EMC-applications
in the frequency-range DC...12GHz.
Operation:
1. Manual operation
2. PC-controlled by IEEE 488 and RS232-interface
LED-Display of switching status
Quantity of switching relays: 2
Switching from 1 input to 2 outputs (1x2)
RSU 2203-40
RF Switching Box with 2 Relays (1x2)
for computer-controlled switching
of RF-signals for EMC-applications
in the frequency-range DC...40GHz.
Connector: SMA 2.9 (10W @40GHz)
Operation:
1. Manual operation
2. PC-controlled by IEEE 488 and RS232-interface
LED-Display of switching status
Quantity of switching relays: 2
Switching from 1 input to 2 outputs (1x2)
RSU 2213
RF Switching Box with 3 Relays
2 (1x2), 1 (1x3)
for computer-controlled switching
of RF-signals for EMC-applications
in the frequency-range DC...12GHz.
Operation:
1. Manual operation
2. PC-controlled by IEEE 488 and RS232-interface
LED-Display of switching status
Quantity of switching relays: 3
2 are switching from 1 input to 2 outputs (1x2)
1 is switching from 1 input to 3 outputs (1x3)
RSU 2223
RF Switching Box with 5 Relay
2 (1x2), 3 (1x3)
for computer-controlled switching
of RF-signals for EMC-applications
in the frequency-range DC...12GHz.
Operation:
1. Manual operation
2. PC-controlled by IEEE 488 and RS232-interface
LED-Display of switching status
Quantity of switching relays: 4
2 are switching from 1 input to 2 outputs (1x2)
2 are switching from 1 input to 3 outputs (1x3)
RSU 3203
RF Switching Box with 3 Relays (1x2)
for computer-controlled switching
of RF-signals for EMC-applications
in the frequency-range DC...12GHz.
Operation:
1. Manual operation
2. PC-controlled by IEEE 488 and RS232-interface
LED-Display of switching status
Quantity of switching relays: 3
Switching from 1 input to 2 outputs (1x2)
RSU 3203-40
RF Switching Box with 3 relays
for computer-controlled switching
of RF-signals for EMC-applications
in the frequency-range DC...40GHz.
Connector: SMA 2,9 (10W@40GHz)
IEEE 488-interface
Quantity of switching relays: 3
RSU 3213
RF Switching Box with 4 Relays
3 (1x2), 1 (1x3)
for computer-controlled switching
of RF-signals for EMC-applications
in the frequency-range DC...12GHz.
Operation:
1. Manual operation
2. PC-controlled by IEEE 488 and RS232-interface
LED-Display of switching status
Quantity of switching relays: 4
1 is switching from 1 input to 2 outputs (1x2), 3 are switching from 1 input to 3 outputs (1x3)
RSU 4203
RF Switching Box with 4 Relays (1x4)
for computer-controlled switching
of RF-signals for EMC-applications
in the frequency-range DC...12GHz.
Operation:
1. Manual operation
2. PC-controlled by IEEE 488 and RS232-interface
LED-Display of switching status
Quantity of switching relays: 4
Switching from 1 input to 2 outputs (1x2)
RSU 4203-40
RF Switching Box with 4 Relays (1x4)
for computer-controlled switching
of RF-signals for EMC-applications
in the frequency-range DC...40GHz.
Connector: SMA 2,9 (10W@40GHz)
Operation:
1. Manual operation
2. PC-controlled by IEEE 488 and RS232-interface
LED-Display of switching status
Quantity of switching relays: 4
Switching from 1 input to 2 outputs (1x2)
RSU 5203
RF Switching Box with 5 Relays (1x2)
for computer-controlled switching
of RF-signals for EMC-applications
in the frequency-range DC...12GHz.
Operation:
1. Manual operation
2. PC-controlled by IEEE 488 and RS232-interface
LED-Display of switching status
Quantity of switching relays: 5
2 relays of them are coupled-switchable
Switching from 1 input to 2 outputs (1x2)
RSU 5203-40
RF Switching Box with 5 Relays (1x2)
for computer-controlled switching
of RF-signals for EMC-applications
in the frequency-range DC...40GHz.
Connector: SMA 2,9 (10W@40GHz)
Operation:
1. Manual operation
2. PC-controlled by IEEE 488 and RS232-interface
LED-Display of switching status
Quantity of switching relays: 5
2 relays of them are coupled-switchable
Switching from 1 input to 2 outputs (1x2)
RSU-IL
Option: Interlock-switch relay switching unit RSU
All relays 1/3 are switched into position neutral as soon as the contact is opened (No path connected)
Connector output: BNC
2/4 CHANNEL RF-POWER METERS
PMS 1084
2-Channel RF-Power-Meter
(4-channels optional)
Frequency range: 100kHz - 6GHz
Measuring range:
100kHz - 4GHz: -60dBm to +20dBm
4GHz - 6GHz:  -45dBm to + 20dBm
RF-impedance: 50 Ohms
Interfaces: RS 232, USB
Included are:
- power cord
- application software
- LabView-driver
- Manual
PMS 1084B
2-Channel RF-Power-Meter
(4-channels optional)
Frequency range: 10kHz - 500MHz
Measuring range: -50dBm to +27dBm
RF-impedance: 50 Ohms
Interfaces: RS 232, USB
Included are:
- power cord
- application software
- LabView-driver
- Manual
PMS-CHA
Expansion of 1 measuring channel of PMS-1084
(Optional expansion of PMS-1084 up to 4-channels is possible)
Frequency range: 100kHz - 6GHz
Measuring range:
100kHz - 4GHz: -60dBm to +20dBm
4GHz - 6GHz:  -45dBm to + 20dBm
RF-impedance: 50 Ohms
PMS-CHAB
Expansion of 1 measuring channel of PMS-1084B
Frequency range: 10kHz - 500MHz
Measuring range: -50dBm to +27dBm
RF-impedance: 50 Ohms
(Optional expansion of PMS-1084 up to 4-channels is possible
ANTENNAS & ACCESSORIES  
ALX-4000
Broadband Antenna
for emission and immunity measurements
Frequency-range: 25MHz - 4GHz
Maximum Input-power:
100MHz: 900W
500MHz: 300W
1000MHz: 210W
2000MHz: 140W
3000MHz: 100W
ALX-4000E
Broadband Antenna
for emission and immunity measurements
Especially optimized version with low antenna factor for emission measurements
Frequency-range: 25MHz - 4GHz
Maximum Input-power:
100W cw; 200W (modulated)
ALX-8000E
Broadband Antenna
for emission and immunity measurements
Especially optimized version with low antenna factor for emission measurements
Frequency-range: 25MHz - 8GHz
Maximum Input-power:
100W cw; 200W (modulated)
AXL-200
Double stacked log. Per. Antenna.
for tests acc. to automotive standards
Frequency range: 200MHz - 2500MHz
Typ. gain: 9dBi±2dBi
Maximum input: 1kW
N-socket
Shipping Container: 94x93x45cm. Weight 13.5 kg.
AXL-80
Stacked Broadband Antenna
Frequency range: 80MHz - 4GHz
Typ. gain: 9dBi±2dBi
Maximum input: 1kW
N-socket
Quick installation and deinstallation
AXL-80-6G
Stacked Broadband Antenna
Frequency range: 80MHz - 10,5GHz
Typ. gain: 9dBi±2dBi
Maximum input: 1kW
N-socket
Quick installation and deinstallation
Tip protected by radom
Especially recommended for tests according to EN61000-4-3
AXL-80S
Double Stacked Broadband Antenna
Special version reduced design compared to standard version AXL-80
Antenna diameter <150cm
also usable for automotive component tests
according to ISO 11452-2
Frequency-range: 80MHz - 4GHz
Typ. gain: 9dBi±3dBi
Maximum input: 1kW
N-input socket
Quick installation and de-installation
HAX-18
Horn Antenna
Frequency-range: 800MHz - 18GHz
Gain: 6dBi - 16dBi
Maximum input power: 300W cw (500W peak)
Input socket: N
HAX-40
Horn Antenna
Frequency-range: 14GHz - 40GHz
Gain:15dBi - 20dBi
Maximum input power: 1kW
Input socket: SMA-compatible
HAX-6
Horn Antenna
Frequency-range: 0.5-6GHz
Gain: >12dBi (from 1GHz)
Maximum input power: 300W cw, 500W interm.
Input socket: N
Other data: see catalogue
HAX-6-KFZ
Horn Antenna especially recommended for automotive components tests
Frequency-range: 1-6GHz
Gain: >12dBi
Maximum input power: 300W cw, 500W interm.
Input socket: N
LAX-10
Active Loop Antenna
for magnetic field measurement
Frequency range: 9kHz - 30MHz
Antenna factor for fictive E-field: 20dB/m
Antenna factor for H-field: -31,5 dB/ cm
Connector: BNC
Loop diameter: 0,5m
Battery pack
charger
MAX-18
Double stacked log-per antenna
for emission measurement and immunity tests
Frequency range: 0.7GHz - 18GHz
typ. gain: 8.6dBi
Maximum input power: 50W
Input socket: N
MAX-9
Double stacked log-per antenna
for emission measurement and immunity tests
acc. to IEC/ EN 61000-4-3
Frequency range: 0.7GHz - 10.5GHz
typ. gain: 10dBi
Maximum input power:
300W (at 1GHz), 150W (at 6GHz)
SAM-18
Biconical antenna for usage
in microwave range
for generation of electrical fields
under free space conditions
for example measurement of
SVSWR acc. to CISPR 16-4-1
Frequency range: 3GHz - 18GHz
typ. gain: 
Maximum input power:
Input socket:
SAM-6
Biconical antenna for usage
in microwave range
for generation of electrical fields
under free space conditions
for example measurement of
SVSWR acc. to CISPR 16-4-1
Frequency range: 1GHz - 6GHz
SAX-10
Active Rod Antenna
Vertical monopole antenna
Frequency range: 9kHz - 30MHz
typ. gain:  +10dB/m ±1,5dB
Connector: BNC
Battery pack
SAX-ACS110
Charger for usage with
SAX-10
SAX-CA
Calibration adapter for SAX-10
SAX-DIV
20dB -Divider for extension of E-measuring range
of SAX-10, including calibration data
SAX-GP
Ground plane 0.6m x 0.6m for usage with
SAX-MIL461
Bonding kit for SAX-10 acc. MIL-STD-461F consisting of a BNC cable double shielded ca. 70 cm, with braid current blocking ferrite in  the center, elbow aluminum angle with BNC bulkhead adapter.
PRE-AMPLIFIER 
 
FPA-2
Broadband Preamplifier
Frequency range: 9kHz -  2GHz
typ. gain: 28dB
low noise
ESD-protected
Connector N/N
includes  power supply
FPA-26
Broadband Preamplifier
Frequency range: 18GHz - 26.5GHz
typ gain: 33dB
Adjustment on 22mm antenna pipe
includes  adapter cable SMA-N
includes  power supply  12V 250mA
Optional: battery pack with charger
FPA-40
Broadband Preamplifier
Frequency range: 18GHz - 40GHz
typ gain: 30dB
Adjustment on 22mm antenna pipe
includes  adapter cable SMA-N
includes  power supply  12V 600mA
Optional: battery pack with charger
FPA-6
Broadband Preamplifier
Frequency range: 10MHz -  6GHz
typ. gain: 30dB
low noise
Connector N/N
incl. power supply
FPA-6A
Broadband Preamplifier
Frequency range: 10MHz -  6GHz
typ. gain: 28dB
low noise
ESD-protected
Connector N/N
includes  power supply
FPA-6B
Broadband Preamplifier
Frequency range: 9kHz -  6GHz
typ. gain: 28dB
low noise
no ESD-protection
Connector N/N
includes  power supply
FPA-18
Broadband Preamplifier
Frequency range: 1GHz - 18GHz
typ gain: 33dB
Adjustment on 22mm antenna pipe
includes  adapter cable SMA-N
includes  power supply  12V 250mA
Optional: battery pack with charger
FPA-BAT
Battery pack for FPA-18 includes  charger
FPD-01PS
Polarization switch incl. Power supply kit for automatic polarization switching between vertical and horizontal polarization by means of an electrical drive.
Useable/mountable with/to any tripod or antenna stand with 3/8" thread.
Antenna tube fixture with a diameter of 22mm.
Max. antenna weight: 5kg
Recommended antenna tripod: Type FSM-1.6 or FSM-2.0
ANTENNA MASTS / ANTENNA ADAPTERS / POLARIZATION SWITCH / CONTROLLER
FSM-1.6
Antenna Stand
Height manual adjustable from 0.9m to 1.6m
Polarization: manual vertical/ horizontal
FSM-2.0
Antenna Stand
Height manual adjustable from 1.2m to 2.0m
Polarization: manual vertical/ horizontal
FSM-2.5
Antenna Stand. Height manual adjustable from 1.2m to 2.5m
Polarization: manual vertical/ horizontal
FSM-4.0
Manual Mast
Height manual adjustable from 0.9m to 4.0m
Polarization: manual vertical/ horizontal
FSM-EXT
Extension for Tripod FSM
PPS
Pneumatical switching of polarization of FSM-1.6 and FSM-2.0
Polarization: vertical/ horizontal
(an additional pneumatical switch is necessary)
MA
Mast adapter to Frankonia Mast/ Tripod for antenna with 22mm rod
MAD
Mast adapter for FSM-1.6 and FSM-2.0
for 22mm rod  double stacked antenna
MAS
Mast adapter for FSM-1.6 and FSM-2.0
for 22mm antenna rods
MAF
Mast adapter for FSM-1.6 and FSM-2.0 for 22mm antenna rods and FSM-EP1
FAM 2-4
Automatic Antenna Mast DIN EN 55022, CISPR 22 Class B
Type: FAM 2-4
Antenna Height Scan electrical: 0.9m - 4m
Polarization electric: 0°-90° vernier adjustment possible
Polarization accuracy: 0.2°
Total height: 4.5m
External dimensions: 1.2m x 0.9m x 4.5m
Weight: 85kg
Maximum antenna weight 12kg
FAM 2-6
Automatic Antenna Mast DIN EN 55022, CISPR 22 Class B
Type: FAM 2-6
Height scan electrical: 0.9m bis 6m
Polarization accuracy: ± 5mm
Polarization electric: 0°-90° vernier adjustment possible
Polarization accuracy: 0.2°
Total height: 6.5m
External dimensions: 1.2m x 0.9m x 6.5m
Weight: 92kg
Maximum antenna weight: 12kg
FPD-01 
Polarization Switching Unit
Type FPD-01
for automatic polarization switching between vertical and horizontal polarization by means of an electrical drive.
Useable/mountable with/to any tripod or antenna stand with
3/8" thread.
Antenna tube fixture with a diameter of 22mm.
Maximum antenna weight: 5kg
Recommended antenna tripod: Type FSM-1.6 or FSM-2.0
FC-06
Controller, type FC-06 for the control of Frankonia antenna masts and turntables.
The standard version allows the control of one antenna mast
and one turntable (optional up to 6 devices).
Fiber optic connectors from controller to turntable and antenna mast : FSMA, 660nm
Interfaces: GPIB (IEEE 488.2), USB
Included in the delivery:
- Control-, Display Software
- Fiber optics
FC-06P
Controller, type FC-06
includes  24V output for the control of Frankonia antenna masts and turntables.
The standard version allows the control of one antenna mast,
one turntable and one Polarization unit (switch) (optional up to 6 devices).
Fiber optic connectors from controller to turntable and antenna mast : FSMA, 660nm
Interfaces: GPIB (IEEE 488.2), USB
Included in the delivery:
- Control-, Display Software
- Fiber optics
FIELD-STRENGTH METERS - EFS
EFS-LASER
Field-strength-meter - Laser E-Field Probe
Frequency range: 10kHz to 6GHz
Measuring range: 0,1V/m to 10.000V/m
Resolution: <0,01dB
Measuring data: X, Y, Z, total field strength
Isotropy:  <1dB @900MHz
EFS-10
Field-strength-meter
E-Field Probe
Frequency range: 10kHz to 9,25GHz
Measuring range: 0,5V/m to 500V/m
Resolution: 0,01V/m
Measuring data: X, Y, Z, total field strength
Isotropy:  0,5dB (typ. 0,3dB) @50MHz
Operation time: Maximum 80h
Consisting of:
E-field probe
(weight 25g, diameter 53mm)
10m fiber optical cable to RS-232-adaptor
includes  RS232-USB adaptor
Battery charger
Calibration report with data
EFS-100
Field-strength-meter
E-Field Probe
Frequency range: 100kHz to 9,25GHz
Measuring range: 0,14V/m to 140V/m
Resolution: 0,01V/m
Measuring data: X, Y, Z, total field strength
Isotropy:  0,5dB (typ. 0,3dB) @50MHz
Operation time: Maximum 80h
Consisting of:
E-field probe
(weight 25g, diameter 53mm)
10m fiber optical cable to RS-232-adaptor
includes  RS232-USB adaptor
Battery charger
Calibration report with data
EFS-5
Field-strength-meter
E-Field Probe
Frequency range: 5kHz to 9,25GHz
Measuring range: 1,5V/m to 1500V/m
Resolution: 0,01V/m
Measuring data: X, Y, Z, total field strength
Isotropy:  0,5dB (typ. 0,3dB) @50MHz
Operation time: Maximum 80h
Consisting of:
E-field probe
(weight 25g, diameter 53mm)
10m fiber optical cable to RS-232-adaptor
includes  RS232-USB adaptor
Battery charger
Calibration report with data
EFS-300
Field-strength-meter - E-Field Probe
Frequency range: 300kHz to 18GHz
Measuring range: 0,17V/m to 170V/m
Resolution: 0,01V/m
Measuring data: X, Y, Z, total field strength
Isotropy:  0,5dB (typ. 0,3dB) @50MHz
Operation time: Maximum 80h
Consisting of:
E-field probe
(weight 25g, diameter 53mm)
10m fiber optical cable to RS-232-adaptor
includes  RS232-USB adaptor
Battery charger
Calibration report with data
EFS-OF20
Optical fiber 20m for
field strength meter EFS-10/ EFS-100
EFS-OF40
Optical fiber 40m for
field strength meter EFS-10/ EFS-100
EFS-500
The Frankonia EFS field-strength-meters especially have been designed for field strength measurements / field homogeneity measurements during radiated immunity tests according to IEC/EN 61000-4-3.
EFS-SWITCH
Switching Relay for up to 10 pcs. of field meters type EFS.
Connection of up to  5 pcs EFS-SWITCH possible.
Interface to PC: COM , USB
EFS-TR
Tripod for Field strength sensor EFS, made from plastics/ wood
Height adjustable from 0,8m to 2,3m for measurement of Homogeneous  field acc. IEC/ EN 61000-4-3
TE-ES
Tripod for Field strength sensors, cameras, small antennas made from wood with extension rod.
Height adjustable from 0,8m to 2,3m for measurement of homogeneous  field acc. IEC/ EN 61000-4-3
includes  floor spider
SOFTWARE
 
BCI-LAB
Control Software for immunity tests acc. to DIN ISO 11452-4 for WINDOWS XP, 7
BCI-LAB UP
Upgrade 5.xx of RF-LAB
Upgrade contains following new features:
>Adaption to the latest standards
>improved spec. of equipment
>improved Display on monitor
-Windows XP, 7 and much more
Additional driver of measuring device in SW: CD-Lab/ RF-LAB
CD/RF-LAB
Control Software.
Software package, consisting of control software
- CD-LAB for immunity tests acc. to IEC 61000-4-6 and
- RF-LAB for immunity tests acc. to IEC 61000-4-3,
-Windows XP, 7
CD-LAB
Control Software for immunity test acc. to IEC 61000-4-6, for WINDOWS 2000, XP
CD-LAB UP
Upgrade to 5.xx of CD-LAB
Upgrade contains following new features:
>Adaption to the latest standards
>improved spec. of equipment
>improved Display on monitor
-Windows XP, 7 and much more
CD-RF-LAB UP 
Upgrade 5.x of RF- and CD-LAB
The update is always the latest version.
Upgrade contains following new features:
>Adaption to the newest standards
>improved spec. of equipment
>improved Display on monitor
-Windows XP, 7 and much more
EM-LAB
Control Software for conducted and radiated emission measurements acc. to CISPR-, FCC-, EN-Standards, for WINDOWS XP, 7
EM-LAB-AUTO
Option: Automation of EMI-Measurements with EM-LAB for control of masts, turntables, …for WINDOWS XP, 7
RF-LAB
Control Software for immunity tests acc. to IEC 61000-4-3, ISO11452-2, etc. and measurement of the uniform area, for WINDOWS XP, 7
RF-LAB UP
Upgrade 5.xx of RF-LAB
Upgrade contains following new features:
>Adaption to the latest standards
>improved spec. of equipment
>improved Display on monitor
-Windows XP, 7
and much more
RF-LAB-A
Additional module: Audio break-through measurements acc. to ETSI EN301489.
This option requires the basic version of the software RF-LAB
EMISSION
 
CORE-6 - Discontinued
EMI receiver
For conducted and radiated emission measurements.
Compliant acc. to CISPR-16-1-1, MIL-STD-461F, VDE 0876 and ANSI C 63.4
Frequency range: 9kHz to 6GHz
Measuring modes: Automatic Scan, Spectrum mode, manual mode
Detectors:
Peak, Quasi-Peak, Average, RMS, RMS-average, CISPR-average
-Operation with a standard PC
-includes  comfortable measuring and report software "EM-Lab"
-Free software updates
-CISPR and MIL-STD Filter (optional)
-Integrated Pre-amplifier (20dB up to 1 GHz, 15dB >1GHz)
-Integrated pulse-limiter up to 30MHz
I/O Interface: USB, RS-232, user port for accessories
Housing: 19" Rack unit, 1RU
Dimensions: 482mm x 45mm x 362mm (BXHXT)
Weight: 5kg
CORE-MIL - Discontinued
Option: compliance to military standards
CORE-FFT - Discontinued
Option: FFT-Analysis for measuring receiver CORE-6
C2-16
Line Impedance Stabilization
Network (LISN) compliant to CISPR 16;
Frequency range: 9kHz- 30MHz;
Characteristics: (50µH+5 Ohm)//50 Ohm;
Phases: 1+N;
Manual and automatic switch of phases;
Max AC-voltage: 250V rms;
Current: 2 x 16A
C4-32
Line impedance stabilization network (LISN) compliant to CISPR 16;
Frequency range: 9kHz- 30MHz;
Characteristics: (50µH+5 Ohm)//50 Ohm;
Phases: 3+N;
Manual and automatic switch of phases;
Max AC-voltage: 250V rms;
Current: 4 x 32A
ACF-01B
Absorption Power Clamp for measurement of absorption power acc. to CISPR 14, CISPR 16 and EN 55014-1
Frequency range: 30 - 1000 MHz
Ball-beared and silicon covered wheels for permanent usage
CVP-1
RF-Probe
Input resistance: 1500 Ohm
Frequency range: 9kHz - 30MHz
Attenuation: 30dB
LVVL
Van Veen Loop Antenna
For magnetic-field measurements acc. to EN 55015/CISPR 15
Frequency-range: 9kHz- 30MHz
Includes all three axes with wooden frame and all connecting cables.
Each antenna individually calibrated with calibration certificate.
Calibration kit optional.
Diameter: 2,0m
Dimensions: 2,1m x 2,1m x 2,6m (h)
Output: 50 Ohms BNC
C-LVVL
Calibration kit for Van Veen Loop Antenna
NFS-100
Near-Field-Probe-Set
Consisting of:
- 1 pc. E-field-probe, 1MHz to 500MHz, BNC-connector, 15cm rod
- 1 pc. H-field-probe, 1MHz to 500MHz, BNC-connector, 50mm diameter
Emission Reference Source - ERS
RSE-1000
Emission Reference Source
Including calibration data, measured on a full-compliance OATS
acc. to CISPR 16-1-4 in 3,0m measuring distance in vertical and horizontal polarization.
The comb generator radiates every 2 MHz a precise peak over the frequency-range from 30MHz to 1000MHz.
GTEM-CELLS & ACCESSORIES   
GTEM 250
GTEM-Cell
Frequency range: 100kHz to 20GHz
Maximum power input, W continuous/pulsed*:500*/1000
Dimensions: 1.27m x 0.64m x 0.44m (L x W x H)
Door size: 30cm x 23cm (WXH)
Maximum EUT-Size: 20cm x 20cm x 15cm (L x W x H)
Size of uniform area (+/-3dB <1GHz): 15cm x 15cm x 10cm (L x W x  H)
Septum height: 250mm
Input impedance: 50 ohms / Input connector N
includes  feed-thru box equipped with:
1 pc. 2x6A power line filter incl 1 pc. socket (Schuko) inside
1 pc. fiber optical feed-thru (3 couple)
1 pc. coax-feed-thru, type N
2 pcs. coax-feed-thru, type SMA
Weight: ca. 30kg
Packing costs are included.
Assembly costs are not included.
GTEM 400
GTEM Cell
Frequency range: 100kHz to 20GHz
Maximum power-input, W continuous/pulsed*:500*/1000
Dimensions:2.20m x1.22m x 0.83m (LxWxH)
Door size: 40cm x 40cm (WxH)
Maximum EUT-Size: 35cm x 40cm x 25cm (LxWxH)
Size of uniform area  (+/-3dB <1GHz): 25cm x 30cm x 13cm (LxWxH)  
Septum height: 400mm
Input impedance: 50 ohms / Input connector N
includes  feed-thru box
1 pc. 2x10A power line filter incl 1 pc. socket (Schuko) inside
1 pc. fiber optical feed-thru (3 couple)
1 pc. coax-feed-thru, type N
2 pc. coax-feed-thru, type SMA
Weight: 120kg
includes  wheeled undercarriage
Packing costs are included.
Assembly costs are not included.
GTEM 500
GTEM-Cell
Frequency range: 100kHz to 20GHz
Maximum power-input, W continuous/pulsed*:500*/1000
Dimensions: 3.00m x1.68m x 1.15m (L x W x H)
Door size: 40cm x 40cm (WxH)
Maximum EUT-Size: 40cm x 40cm x 30cm (L x W x H)
Size of uniform area  (+/-3dB <1GHz): 30cm x 35cm x 17cm (L x W x H)
Septum height: 500mm
Input impedance: 50 ohms / Input connector N
includes  feed-thru box
1 pc. 2x10A power line filter incl 1 pc. socket (Schuko) inside
1 pc. fiber optical feed-thru (3 couple)
1 pc. coax-feed-thru, type N
2 pcs. coax-feed-thru, type SMA
1 pc. unequipped technical panel
Weight: 250kg
includes  wheeled undercarriage
Packing costs are included.
Assembly costs are not included.
GTEM 750
GTEM-Cell
Frequency range: 100kHz to 20GHz
Maximum power-input, W  continuous/pulsed*:700*/1500
Dimensions: 4.0m x 2.20m x 1.50m (L x W x H)
Door size: 60cm x 60cm (W x H)
Maximum EUT-Size: 60cm x 60cm x 50cm (L x W x H)
Size of uniform area (+/-3dB <1GHz): 45cm x 45cm x 25cm (L x W x H)
Septum height: 750mm
Input impedance: 50 ohms / input connector N
includes  feed-thru box
1 pc. 2x10A power line filter incl 1 pc. Socket (Schuko) inside
1 pc. fiber optical feed-thru (3 couple)
1 pc. coax-feed-thru, type N
2 pcs. coax-feed-thru, type SMA
2 pcs. unequipped technical panels
includes  wheeled undercarriage
Weight: 400kg
Packing costs are included.
Assembly costs are not included.
GTEM 1000
GTEM-Cell
Frequency range: 100kHz to 20GHz
Maximum power input, W continuous/*pulsed:700W*/ 1500W
Dimensions: 5.00m x 2.71m x 1.88m (L x W x H)
Door size: 80cm x 80cm (W x H)
Maximum EUT-Size: 75cm x 75cm x 70cm (L x W x H)
Size of uniform area (+/-3dB <1GHz): 60cm x 60cm x 30cm (L x W x H)  
Septum height: 1.000mm
Input impedance: 50 ohms / input connector N
includes  feed-thru box
1 pc. 2x10A power line filter incl 1 pc. Socket (Schuko) inside
1 pc. fiber optical feed-thru (3 couple)
1 pc. Coax-feed-thru, type "N"
2 pcs. Coax-feed-thru, type "SMA"
2 pcs. unequipped technical panels
includes  wheeled undercarriage
Weight: ca. 700kg
Packing costs are included.
Assembly costs are not included.
GTEM 1250
GTEM-Cell
Frequency range: 100kHz to 20GHz
Maximum power-input; W continuous/*pulsed:800/1200*
Dimensions: 6.10m x 3.20mx 2.15m (L x W x H)
Door size: 80cm x 110cm (W x H)
Maximum EUT-Size: 95cm x 95cm x 85cm (L x W x H)
Size of uniform area (+/-3dB < 1GHz): 75cm x 75cm x 42cm (L x W x H)  
Septum height: 1.250
Input impedance: 50 ohms / input connector N
includes  feed-thru box
1 pc. 2x10A power line filter incl 1 pc. socket (Schuko) inside
1 pc. fiber optical feed-thru (3 couple)
1 pc. coax-feed-thru, type N
2 pcs. coax-feed-thru, type SMA
includes  wheeled undercarriage
1 pc. unequipped technical panel
Weight: 850kg
Packing costs are included.
Assembly costs are not included.
GTEM 1500
GTEM-Cell
Frequency range: 100kHz to 20GHz
Maximum power-input, W continuous/*pulsed:850/1300*
Dimensions:  7.10m x 3.81m x 2.50m (L x W x H)
Door size:  0.80m x 1.20m (W x H)
Maximum EUT-Size:  (L x W x H) 1.20m x 1.20m x 1.00m
Size of uniform area (+/-3dB <1GHz): 1.00m x 1.00m x 0.50m
Septum height: 1.500mm
Input impedance: 50 ohms / input connector N
includes  feed-thru box
1 pc. 2x10A power line filter incl 1 pc. socket (Schuko) inside
1 pc. fiber optical feed-thru (3 couple)
1 pc. coax-feed-thru, type N
2 pcs. coax-feed-thru, type SMA
1 pc. unequipped technical panel
includes  wheeled undercarriage
Weight: 1000kg
Packing costs are included.
Assembly costs are not included.
GTEM 1750
GTEM-Cell
Frequency range: 100kHz to 20GHz
Maximum power-input, W continuous/*pulsed:900/1400*
Dimensions: 8.10m x 4.30m x 2.80m (L x W x H)
Door size:  0.80m x 1.30m (W x H)
Maximum EUT-Size:  (L x W x H) 1.40m x 1.40m x 1.15m
Size of uniform area (+/-3dB <1GHz): 1.25m x 1.25m x 0.58m
Septum height: 1.750mm
Input impedance: 50 ohms / input connector N
includes  feed-thru box
1 pc. 2x10A power line filter incl 1 pc. socket (Schuko) inside
1 pc. fiber optical feed-thru (3 couple)
1 pc. coax-feed-thru, type N
2 pcs. coax-feed-thru, type SMA
2 pcs. unequipped technical panels
includes  wheeled undercarriage
Weight: 1300kg
Packing costs are included.
Assembly costs are not included.
GTEM 2000
GTEM-Cell
Frequency range: 100kHz to 20GHz
Maximum power-input, W continuous/*pulsed: 1000/1600*
Dimensions: 9.10m x 4.84m x 3.14m (L x W x H)
Door size:  0.80m x 1.60m (W x H)
Maximum EUT-Size: (L x W x H)1,75m x 1,75m x 1,30m
Size of uniform area (+/-3dB <1GHz): 1.50m x 1.50m x 0.65m
Septum height: 2.000mm
Input impedance: 50 ohms / input connector N
includes  feed-thru box
1 pc. 2x10A power line filter incl 1 pc. socket (Schuko) inside
1 pc. fiber optical feed-thru (3 couple)
1 pc. coax-feed-thru, type N
2 pcs. coax-feed-thru, type SMA
2 pcs. unequipped technical panels
includes  wheeled undercarriage
Weight: 1650kg
Packing costs are included.
Assembly costs are not included.
GTEM-B01
OPTION B01: EIA 7/8'' Input Connector (Maximum 3GHz)
GTEM-B02
OPTION B02: EIA 7/16'' Input Connector (Maximum 3GHz)
GTEM-B04
OPTION B04: Upgrade Input Power 1400W (up to 3GHz)
The max. input power is limited by the specification of the max input power of the selected GTEM
GTEM-B05
OPTION B05:fiber optical feed-thru (3 Pairs)
GTEM-B06
OPTION B06: N-Feed thru
GTEM-B07
OPTION B04: SMA-feed thru
GTEM-B08
OPTION B08: Additional power socket for EUT
GTEM-B09
OPTION B09: Internal illumination (Halogen, 50 W)
GTEM-B09L
OPTION B09L: Internal illumination (LED, 20 W)
GTEM-B10
OPTION B10: AC line filter 16A/5 wires
GTEM-B11
OPTION B11: EMI-Filter Upgrade 2x10A to 4x32A 440V/ 250V AC/ DC
Only for GTEM 750/1000/ 1250/ 1500/ 1750/2000
GTEM-B12
OPTION B12: Filter 4 x 64A, 440V/ 250V AC/ DC
Only for GTEM 750/1000/ 1250/ 1500/ 1750/2000
GTEM-B13
OPTION B13: Interlock relay at the door
GTEM-B14
OPTION B14:DSub Signal Line Filter  (25 pin)
GTEM-B15
OPTION B15: Second door close to input
Only for GTEM 750/1000/ 1250/ 1500/ 1750/2000
GTEM-B16
OPTION B16: Window in door
Diameter 200mm
GTEM-B17
OPTION B17: Gas/ Water feed thru panel
GTEM-B18
OPTION B18: Honeycomb
Not available for GTEM-250
GTEM-B19
OPTION B19: Fans (2 pcs)
on technical panel
Not available for GTEM-250
GTEM-B20
OPTION B20:Door for tests acc. to SAE J1752/3
Only for GTEM 750/1000/ 1250/ 1500/ 1750/2000
GTEM-B21
OPTION B21: Wheeled Undercarriage (GTEM 250)
---
GTEM-B23
OPTION B23: Vertical positioning
turn of door position, plastic table over pyramids
only for GTEM 250/ 500
GTEM-B25
OPTION B25: 9 pin DSUB Filter
GTEM-B26 
OPTION B26: Integrated circuit testing
GTEM-B27
OPTION B27:  installation panel (not equipped)
GTEM-B28
OPTION B28: Fan kit includes  channel for heat sink
GTEM-B29
OPTION B29: fiber optical feed through (1 pair)
GTEM-B30
OPTION B30: Input Power 1600W (3GHz) only for GTEM-500 to GTEM 2000
GREM-B31
OPTION B30: Input Power 1000W (3GHz) only for GTEM-250
GTEM-B32
OPTION B32:fiber optical feed-thru (6 Pairs)
MAN-1000M
Manually operated EUT-manipulator (x-y-z) for GTEM-1000
The FRANKONIA GTEM EUT-manipulator is a solution for easily  rotating the EUT into the three orthogonal axis positions acc. to  IEC/EN 61000-4-20.
The EUT can be rotated by 120 degrees and optionally in 5, 10 and 60 degree increments.
Maximum EUT weight: 25kg
Maximum EUT size: 33cm x 33cm x 33cm
MAN-1250M
Manually operated EUT-manipulator (x-y-z)  for GTEM-1250.
The FRANKONIA GTEM EUT-manipulator is a solution for easily rotating the EUT into the three orthogonal axis positions acc. to IEC/EN 61000-4-20.
The EUT can be rotated by 120 degrees and optionally in 5, 10 and 60 degree increments.
Maximum EUT weight: 25kg
Maximum EUT size: 41cm x 41cm x 41cm
MAN-1500M 
Manually operated EUT-manipulator (x-y-z) for GTEM-1500.
The FRANKONIA GTEM EUT-manipulator is a solution for easily rotating the EUT into the three orthogonal axis positions acc. to  IEC/EN 61000-4-20.
The EUT can be rotated by 120 degrees and optionally in 5, 10 and 60 degree increments.
Maximum EUT weight: 25kg
Maximum EUT size: 50cm x 50cm x 50cm
MAN-1750M
Manually operated EUT-manipulator (x-y-z) for GTEM-1750.
The FRANKONIA GTEM EUT-manipulator is a solution for easily rotating the EUT into the three orthogonal axis positions acc. to IEC/EN 61000-4-20.
The EUT can be rotated by 120 degrees and optionally in 5, 10 and 60 degree increments.
Maximum EUT weight: 30kg
Maximum EUT size: 60cm x 60cm x 60cm
MAN-500M 
Manually operated EUT-manipulator (x-y-z) for GTEM-500
The FRANKONIA GTEM EUT-manipulator is a solution for easily  rotating the EUT into the three orthogonal axis positions acc. to IEC/EN 61000-4-20.
The EUT can be rotated by 120 degrees and optionally in 5, 10 and 60 degree increments.
Maximum EUT weight: 10kg
Maximum EUT size: 16.7cm x 16.7cm x 16.7cm
MAN-750M
Manually operated EUT-manipulator (x-y-z) for GTEM-750.
The FRANKONIA GTEM EUT-manipulator is a solution for easily rotating the EUT into the three orthogonal axis positions acc. to IEC/EN 61000-4-20.
The EUT can be rotated by 120 degrees and optionally in 5, 10 and 60 degree increments.
Maximum EUT weight: 15kg
Maximum EUT size: 25cm x 25cm x 25cm
OPEN TEM-CELLS   
TEM 220
Open TEM-Cell, type TEM 220
for immunity tests on automotive components acc. to ISO 11452-3 and pre-compliance emission measurements.
Frequency-range: DC - 220MHz
Height under coupling plate: 333mm
Maximum field-strength (1,5kW input): 800V/m
Maximum input power: 1,5kW
Dimensions: 1.800mm x 1.600mm x 730mm (LXWXH)
Weight: 55kg
Packaging costs are included
TEM 500
Open TEM-Cell, type TEM 500
for immunity tests on automotive components acc. to ISO 11452-3 and pre-compliance emission measurements.
Frequency-range: DC - 500MHz
Height under coupling plate: 147mm
Maximum field-strength (1kW input): 1.550V/m
Maximum input power: 1kW
Dimensions: 1.020mm x 900mm x 360mm (LXWXH)
Weight: 13,5kg
TEM 1000
Open TEM-Cell, type TEM 1000
for immunity tests on automotive components acc. to ISO 11452-3 and pre-compliance emission measurements.
Frequency-range: DC - 1GHz
Height under coupling plate: 73mm
Maximum field-strength (1kW input): 2.700V/m
Maximum input power: 1kW
Dimensions: 540mm x 450mm x 168mm (LXWXH)
Weight: 3,5kg
Packaging costs are included
TEM 3000
Open TEM-Cell, type TEM 3000 for immunity tests on automotive components acc. to ISO 11452-3 and pre-compliance emission measurements.
Frequency-range: DC - 3GHz
Height under coupling plate: 25mm
Maximum field-strength (400W input): 5,6kV/m
Maximum input power: 400W
Dimensions: 440mm x 180mm x 80mm (LXWXH)
Weight: 1.1kg
Packaging costs are included
STRIP LINES   
 
SR50/1000
Strip line, type SR50/1000
Strip-line for immunity-tests acc. to
DIN/ISO 11452-5, 50 Ohm - version.
Frequency-range: DC to 1GHz
Maximum input-power: 1000W (long term)
Impedance: 50 Ohm (+/- < 5 Ohm)
Wave impedance: 377 Ohm
VSWR: better than 1,22 up to 1GHz
Dimensions: 4300mm x 1500mm x 1050mm (LXWXH)
Height of the table: 950mm
Weight: approx. 140kg
includes  rotating metallic table.
For storage the strip line can be divided in
parts 2 x (2150mm x 850mm x 1650mm).
The packaging costs of the strip line in a wooden
SR 90/1000
Strip-line
Strip-line for immunity-tests acc. to
DIN/ISO 11452-5, 90 Ohm - version.
Frequency-range: DC to 1GHz
Maximum input-power: 100W (long term); (>100W with impedance adapter)
Impedance: 90 Ohm (+4/ -6 Ohm)
Wave impedance: 377 Ohm
VSWR: better than 1,92 up to 1GHz
Dimensions: 3500mm x 900mm x 1000mm (LXWXH)
Height of the table: 850mm
Weight: approx. 90kg
includes  Rotating metallic table.
Optional: 50 to 90 Ohm adapter
The packaging costs of the strip line in a wooden box is included
SR1000-50/20
Strip line, Typ SR1000-50/20
Strip line for immunity-tests acc. to
DIN/ISO 11452-5, 50 Ohm - version.
Height under the plate: 20cm
Frequency-range: DC to 1GHz
Maximum input-power: 1000W (long term)
Impedance: 50 Ohm (+/- < 5 Ohm)
Wave impedance: 377 Ohm
VSWR: better than 1,1 up to 1GHz
Dimensions: 4300mm x 1500mm x 1050mm (LXWXH)
Height of the table: 900mm
Weight: approx. 140kg
includes  Rotating metallic table.
For storage the strip line can be divided in parts 2 x (2150mm x 850mm x 1650mm).
The packaging costs of the strip line in a wooden box is included
SRA5090
Adapter 50/90 Ohm
TESTING TABLES (All Tables ship from China)
KFZ-TI
Test Table with ground-plane
Wooden test table (without any metal parts)
Dimensions: 2.5m x1.0m x 0.9m,
includes  Ground-plane (can be taken away) is made from
1.25mm thick, hot galvanized steel sheet. includes  copper belts
guarantee a low-resistive ground contact to the contact
strip at the chamber wall.
Length of copper belts: 0.5m
DC-Resistance Table- Chamber: < 2.5m ohms
table is acc. to  ISO 11452 und CISPR 25.
KFZ-KL
Contact Strip
Contact strip for electrical contact from the ground plane of the test table to the shielding. The contact strip is mounted between two absorber rows and has a broad contact to the shielding panel. The strip consists of 2 rows of Cu-Be springs.
Copper belts (cables) are clamped into the slot to make electrical contact.
Length: 2.5m
MT 1.0X0.8
Low Reflexion Testing Table
acc. to CISPR 22, CISPR 32
Dimensions (LxWxH): 1000mm x 800mm x 800mm
Material: Styropor ESP37
Maximum Load: 200kg
Color: light grey (RAL 7035)
Cover material: PVC
Weight 20kg
Packaging costs are not included.
MT 1.5X1.0
Low Reflexion Testing Table
acc. to CISPR 22
Dimensions (LxWxH): 1500mm x 1000mm x 800mm
Footprint: 1.200mm diameter (suitable for turntables with 1.2 m diameter)
Material: Styropor ESP37
Maximum Load: 200kg
Color: light grey (RAL 7035)
Cover material: PVC
Packaging costs are not included.
MT 1.5X1.2
Low Reflexion Testing Table
acc. to CISPR 22
Dimensions (LxWxH): 1500mm x 1200mm x 800mm
Material: Styropor ESP37
Maximum Load: 200kg
Color: light grey (RAL 7035)
Cover material: PVC
Packaging costs are not included.
MT-R 1.5 X 0.8
Low Reflexion Testing Table
acc. to CISPR 22
Diameter:1500mm
Height: 800mm
Material: Styropor ESP37
Max. Load: 200kg
Color: light grey (RAL
Packaging costs are not included.
MT 2.0X1.0
Low Reflexion Testing Table
acc. to CISPR 22
Dimensions (LxWxH): 2000mm x 1000mm x 800mm
Material: Styropor ESP37
Maximum Load: 200kg
Color: light grey (RAL 7035)
Cover material: PVC
Packaging costs are not included.
MT 2.0X1.2
Low Reflexion Testing Table
acc. to CISPR 22
Dimensions (LxWxH): 2000mm x 1200mm x 800mm
Material: Styropor ESP37
Maximum Load: 200kg
Color: light grey (RAL 7035)
Cover material: PVC
Packaging costs are not included.
FREESTANDING TURNTABLE FTF (All Tables ship from China)
FTM-0,6-0,2
Turntable, freestanding
Type:  FTM-0,6-0,3
Mobile turntable with two handles for flexible or fixed installation.
Surface cover plate: 8,0mm aluminum
Diameter: 0,6m
Maximum load: 200kg
Slewing range: +200°/-200°
Rotational speed: 0,5 rpm - 3 rpm, adjustable in 30 steps
Accuracy: 0,1°
FTM-0,8-0,2 
Turntable, freestanding
Type:  FTM-0,8-0,3
Mobile turntable with two handles for flexible or fixed installation.
Surface cover plate: 8,0mm aluminum
Diameter: 0,8m
Maximum load: 200kg
Slewing range: +200°/-200°
Rotational speed: 0,5 rpm - 3 rpm, adjustable in 30 steps
Accuracy: 0,1°
FTF-0,6-0,3 
Turntable, freestanding
Type: FTF-0,6-0,3
Diameter: 600mm or 800mm (to be chosen) (please specify with the order which diameter)
Max. Load: 300kg
Height:: 160mm with adjustable stands
152mm without stands
Angel of rotation: +/- 360 Grad
Positioning accuracy: +/- 0,5 Grad
Controllable with the included software or with external controller, type FC-05 (connection via optical fiber)
Accessories included:
- Control software
- Optical Converter for USB
- 10m optical fiber
- Power supply cable, USB cable
FTF-1.5-0.5
Turn-Table
Metallic surface, electrical contacted
to the Ground-plane, for step less
installation into the raised floor.
Diameter: 1,50m
Max. load: 500kg
Accuracy: 0,1°
FC-05
Controller, type FC-05
for the control of Frankonia antenna masts and turntables (max. 4 instruments).
Fiber optic connectors from controller to turntable and antenna mast : FSMA, 660nm
Interfaces: GPIB, USB
Included in the delivery:
- Control-, Display Software
- Fiber optics
FC-06
Controller, type FC-05
for the control of Frankonia antenna masts and turntables.
The standard version allows the control of one antenna mast and one turntable (optional up to 6 devices).
Fibre optic connectors from controller to turntable and antenna mast : FSMA, 660nm
Interfaces: GPIB (IEEE 488.2), USB
Included in the delivery:
- Control-, Display Software
- Fibre optics
FC-06P
Controller, type FC-06P
incl. 24V output for the control of Frankonia antenna masts and turntables.
The standard version allows the control of one antenna mast, one turntableand one Polarization unit (switch) (optional up to 6 devices).
Fibre optic connectors from controller to turntable and antenna mast : FSMA, 660nm
Interfaces: GPIB (IEEE 488.2), USB
Included in the delivery:
- Control-, Display Software
- Fibre optics
Frankonia Chambers
AVTC
AUTOMOTIVE VEHICLE TESTING CHAMBER - AVTC
Anechoic chamber for vehicle testing
ACTC
AUTOMOTIVE COMPONENT TESTING CHAMBER - ACTC
Anechoic chamber for testing of automotive components
CHC
CHC "COMPACT HYBRID CHAMBER"
COMPACT ANECHOIC CHAMBER, LINED WITH FERRITE ABSORBERS AND PARTIALLY WITH HYBRID ABSORBERS FOR FULL COMPLIANCE IMMUNITY TESTS ACC. IEC (EN) 61000-4-3 AND PRE- COMPLIANCE EMISSION MEASUREMENTS, MEASURING DISTANCE: 3,0m
FREQUENCY-RANGE: 26MHz to 18GHz CONSTRUCTED AS "SEMI-ANECHOIC CHAMBER"
A: SHIELDING TECHNIQUE
The shielding will be realized as a self-supporting, screwed modular construction. The individual shielding modules are manufactured from hot galvanized sheet steel of a constant thickness of 2mm, which are double-edged at the four sides. The max. dimensions of the individual panels are 3.000mm x 1.200mm (LXW). The perfect, RF-shielded and electrical connection of the individual modules among each other is guaranteed by use of wire mesh gaskets and a screw distance of 75mm.
It can be easily assembled (disassembled if necessary) and offers a significant advantage when compared to welded solutions.
The construction is totally self-supporting and independent with the main building. The floor of the building must be even (max. permissible waviness: +/- 5mm, measured over a length of 5m) and must be proof against rising moisture. External dimensions of the anechoic chamber: 7.355mm x 3.755mm x 3.300mm (LXWXH) (plus steel construction):
Following installations are included in the quoted price:
1 pc. Single leaf swing door, Type SLD , with 3 rows of beryllium contact springs, manual opening/closing operation supported by a lever arm mechanism.
Clear opening dimensions: 1.238mm x 2.118mm (WXH) 2 pc. honeycomb inserts for the ventilation of the chamber,
Dimensions: 400mm x 400mm,
The honeycombs are furnished with flanges to allow the connection to a ventilating fan or air-conditioning system
1 pc. power-line filter, 250VAC, 50/60Hz, 2x32A
1 pc. power-line filter, 250VDC, 2x32A
Electrical installation, consisting of:
-1 pc. distribution box with fuse elements and earth-leakage circuit breaker
-1 pc. main-switch
-1 pc. emergency-off switch
-1 pc. emergency light over the door
-4 pc. halogen procectors
-2 pc. floor connecting boxes equipped with (each)
- 4pc. protective contact sockets, 230V/16A
- cable channels from the pentration panel to the floor connecting boxes
- complete cabling
2 pc. penetration panels, equipped with (each): - 4 pc. Coax-connectors, type "N" - 4 pc. Coax-connectors, type "BNC"
- 1 pc. feed-through for optical fibre
Elevated floor, mounted onto adjustable stays.
Height adjusted to the door-step.
Dimensions of the removable panels: 600mm x 600mm
Thickness of the panels: 38mm
Maximum Load: 500kg/sqm
Complete floor covered with a metallic ground-plane, made of 2mm zinc plated steel panels, electrically conducted to the wall shielding panels
B: Absorber lining:
1. Ferrite absorbers:
The walls and the ceiling of the quoted chamber are lined with
Ferrite-absorbers, type F006.
For the floor 7,2sqm removable ferrite-panels are included, which are necessary for immunity tests acc. to IEC 61000-4-3 between the antenna and the EUT. The single ferrite-tiles (100mm x 100mm) are premounted onto carrier-panels with a size of 600mm x 600mm. The complete
thickness of these panels, including the ferrite-tiles is 25mm.
During the installation the carrier-panels will be screwed (on the four corners) into a sub-construction, which is fixed on the shielding panels.
2. Pyramid absorbers:
For the frequency extension up to min. 18GHz an additional, partial lining with Pyramid absorbers is necessary.
Following surfaces are lined with Pyramid absorbers:
- 2 long walls: surface 2,4m x 3,0m
- 2 small wall: surface 3,3m x 3,0m
- Ceiling: surface 2,4m x 2,4m
- Floor: surface 2,4m x 3,0m
Complete length of Ferrite absorbers + Pyramid absorbers: 500mm.
The combination of Ferrite-, and Pyramid absorbers correspond to our Hybrid absorbers, type H 450B2.
C: Performance of the chamber:
The quoted anechoic chamber is designed for full-compliance immunity tests acc. to IEC (EN) 61000-4-3 and for pre-certification emission measurements.
We guarantee following technical performance:
Immunity tests acc. to IEC (EN) 61000-4-3:
Surface of the uniform area: 1,5m x 1,5m ( 0,8m above the floor)
Max. field deviation (uniform area): -0dB/+6dB on 75% of the 16 measuring points
Measuring distance: 3,0m
Frequency-range: 80MHz to 18GHz
At frequencies >1GHz the size of the uniform area depends on the antenna pattern and the measuring distance.
Emission measurements:
Max. deviation from the "Normalized Site Attenuation" (NSA) acc. to CISPR 16-1-4 (measurement with reduced antenna height scan):
30MHz to 200MHz: +/- 6dB
200MHz to 1GHz: +/- 4dB
Site-VSWR acc. to CISPR 16-1-4: <8dB at 90% of all measuring points, (additional floor absorbers necessary)
Frequency-range: 1-18GHz
Shielding attenuation: For shielded rooms, equipped with doors, type SLD , (3 rows of contact-springs) we guarantee following values of shielding attenuation, measured acc. to
EN 50147-1:
Magnetic Field-80dB-10kHz
Magnetic Field-100dB-100kHz
Magnetic Field-100dB-1MHz
Plane wave-120dB-100MHz
Plane wave-120dB-400MHz
Plane wave-120dB-1GHz
Micro wave-100dB...80dB - 1GHz...18GHz
WARRANTY:
The warranty period for the specified shielding attenuation is 5 years. Excepted are movable parts (on the doors); the warranty period for these parts is 2 years.
The quoted price includes the turn-key assembly with Frankonia supervisor and 2 local workers provided by the customer (includes  Electrician), includes  travelling expenses.

 

 

 

 

Frankonia product Line

Reliant EMC Product Lines