Reliant EMC

Conducted and Immunity Test Systems

Frankonia Conducted and Immunity Test Systems Quick Links
Compact Immunity Test System CIT-10 10kHz-400MHz Diagram
Compact Immunity Test System CIT-10 10kHz-400MHz
Immunity Test System RIS 3000 RIS 6000 Circuit Diagram
Immunity Test System RIS 3000 RIS 6000
Magnetic Field and Low Frequency Test System MTS-800

 

 

Compact Immunity Test System CIT-10

Immunity Test System "Type CIT-10", conducted, 10kHz - 400MHz, according to IEC/EN 61000-4-6, ISO 11452-4, MIL-STD 461
 
FRANKONIA CIT-10
FRANKONIA CIT-10 Immunity Test System
 
Description
The CIT-10 is a complete test system for conducted RF-immunity tests according to IEC/EN 61000-4-6, ISO 11452-4, MIL-STD 461E/F CS114, SAE-J1113-2, DC 10614 and similar standards. Its internal RF-generator and RF-power amplifier produce output signals with max. up to 150 W within a frequency range from 100 (10) kHz up to 400 MHz. Generated signals are measured via one of the max. 3 internal RF-Voltmeters. Furthermore via an optional, internal directional coupler forward and reflected power can be measured. The whole test system allows full automatic tests for the specified frequency range. As a “stand-alone” test system the CIT-10 is convincing by its easy and comfortable handling and the excellent cost-performance ratio. Add-ons like coupling/decoupling devices are available as well.
 
Special Features:
• Conducted RF immunity tests according to IEC/EN 61000-4-6 and BCI tests according to ISO 11452-4 and MIL–STD 461E
• Signal generator, RF-power amplifier, RF-power meter and directional coupler (optional) in one 19”-case
• Stand-alone operation possible with optional available net book
• Control-software included
• Most important parameters are shown on an integrated display
• Automatic EUT-monitoring
• Operation via USB port of a PC or Notebook
• Complete range of CDNs available
 
Applications:
 
Immunity Testing:
Testing according to IEC/EN 61000-4-6, ISO 11452-4, MIL-STD 461E/F CS114, DC10614 can be performed automatically.
 
Generation, amplification and verification of RF-Signals:
The internal amplifier amplifies any signal from 100 (10) kHz up to 400 MHz. By using the internal generator a desired narrow band signal can be generated. Signals up to 30 dBm can be measured at the same time. If a directional coupler is installed, forward and reflected power are measured as well.
 
For details on the CIT-10, please download the following Data Sheets:


Immunity Test Systems RIS 3000 / RIS 6000

 
Immunity Test System "Type RIS 3000 / 6000", radiated, according to IEC/EN 61000-4-3, ISO 11452-2, MIL-STD RS 103
 
Description
The setup of a radiated immunity test system can be done in the conventional way with many separate instruments or in a more comfortable and less risky way with our new EMC control unit, type ECU-3/-6

 

FRANKONIA Setup of a Radiated Immunity Test System according to IEC EN 61000-4-3
Setup of a Radiated Immunity Test System according to IEC EN 61000-4-3
 
For details on the RIS 3000 and RIS 6000 Immunity Test Systems, please download the following Data Sheets:

 

 

Magnetic Field Test System / Low-Frequency Test System for Emission and Immunity Tests / MTS-800

 
FRANKONIA MTS-800
MTS-800

 

Description
The MTS-800 is a compact test system for broadband generation
and measurement of magnetic fields.
Its internal components allow automatic EMC tests according to automotive standards where high field strength need to be generated or measured.
In combination with our triaxial Helmholtz coils, fully automated
susceptibility tests are possible at magnetic field strength up to 1000 A/m for frequencies from DC to 1 kHz.
Lower field strength can be generated for frequencies up to 250 kHz. Due to the triaxial set-up of our Helmholtz coil major improvement in device handling is achieved because there is no need to turn an EUT during tests.

The MTS-800 complies to all magnetic field requirements of
relevant EMC and military standards.
 
Tests and measurements are controlled by a program which will set most parameter automatically. For any relevant standard, which are fulfilled by the MTS-800, limit values are already included into the software package, although any different value can be defined by a user. After every test full reports will be created automatically. Report layout is pre-defined, though any user-defined layout is possible.
High performance is guaranteed by a self-calibration process which utilizes an internal source as reference.
 
According to
IEC/EN 55103-1/2, IEC/EN 61000-4-16, IEC/EN 61000-4-8, SAE J1113-22, ISO 11452-8, MIL-STD-461E (CE101, RE101, CS101, CS109 and RS101), Automotive manufacturer standards
 
Special Features:
• Frequency range for emission and immunity measurements:
DC – 250 kHz
• 800W precision power amplifier, signal generator and spectrum analyzer in one compact unit
• All instruments may as well be used as stand-alone devices
• Powerful but easy to operate software, fully expandable for future standards modifications
• Standard software allows easy operation, report generation and integration of external measuring instrument for EUT
monitoring
• Prepared for connection of external multimeter for EUT control
• Fully automated tests with triaxial Helmholtz coil. Software
controlled generation of magnetic field in x-, y- and z- direction; no need to turn the EUT!
• Large variety of extensive accessories available
 
For details on the MTS-800 Magnetic-Field Test System, Low-Frequency Test System, please download the following Data Sheets:
 
 
Request a Quote / Contact Us!

 

FRANKONIA Product Line